Irrigant flow characteristics in the root canal with internal root resorption: a computational fluid dynamics evaluation

dc.authoridCiftcioglu, Elif/0000-0002-2578-0168
dc.authoridKeleş, Ali/0000-0003-2835-767X
dc.authoridyücel, özgün/0000-0001-8916-2628
dc.authorscopusid36196266900
dc.authorscopusid57038317200
dc.authorscopusid57212222958
dc.authorscopusid8731395200
dc.authorscopusid8853818700
dc.authorwosidCiftcioglu, Elif/GQQ-9704-2022
dc.authorwosidKeleş, Ali/J-5897-2015
dc.authorwosidyücel, özgün/AAE-3071-2020
dc.contributor.authorCiftcioglu, Elif
dc.contributor.authorYucel, Ozgun
dc.contributor.authorIsik, Vasfiye
dc.contributor.authorKeles, Ali
dc.contributor.authorKayahan, Mehmet Baybora
dc.contributor.otherEndodonti / Endodontics
dc.date.accessioned2024-05-25T11:27:40Z
dc.date.available2024-05-25T11:27:40Z
dc.date.issued2022
dc.departmentOkan Universityen_US
dc.department-temp[Ciftcioglu, Elif] Istanbul Okan Univ, Dept Endodont, Fac Dent, Istanbul, Turkey; [Yucel, Ozgun] Gebze Tech Univ, Dept Chem Engn, Fac Engn, Kocaeli, Turkey; [Isik, Vasfiye; Kayahan, Mehmet Baybora] Istanbul Hlth & Technol Univ, Dept Endodont, Fac Dent, Istanbul, Turkey; [Keles, Ali] Ondokuz Mayis Univ, Dept Endodont, Fac Dent, Samsun, Turkeyen_US
dc.descriptionCiftcioglu, Elif/0000-0002-2578-0168; Keleş, Ali/0000-0003-2835-767X; yücel, özgün/0000-0001-8916-2628en_US
dc.description.abstractIrrigation dynamics of syringe irrigation with different needle designs (side-vented, double side-vented, notched) and ultrasonic irrigation in the root canal with internal root resorption were evaluated using a computational fluid dynamics model. A micro-CT scanned mandibular premolar was used for modeling internal root resorption. The needles and the ultrasonic tip were positioned at 2, 4, and 5 mm from the working length. The insertion depth and the irrigation model were found influential on the shear stress and the irrigant extension. The extension of the irrigant increased toward 2-5 mm from the working length. Ultrasonic irrigation revealed the highest shear stress values regardless of the insertion depth. The shear stress distribution on the resorption cavity walls gradually increased when the needles were positioned coronally. The residence time of the irrigant in the canal was affected by the needle position relative to the internal root resorption cavity and the needle type.en_US
dc.identifier.citation2
dc.identifier.doi10.1007/s10266-022-00698-5
dc.identifier.endpage776en_US
dc.identifier.issn1618-1247
dc.identifier.issn1618-1255
dc.identifier.issue4en_US
dc.identifier.pmid35218447
dc.identifier.scopus2-s2.0-85125239369
dc.identifier.scopusqualityQ1
dc.identifier.startpage769en_US
dc.identifier.urihttps://doi.org/10.1007/s10266-022-00698-5
dc.identifier.urihttps://hdl.handle.net/20.500.14517/1072
dc.identifier.volume110en_US
dc.identifier.wosWOS:000761312400001
dc.identifier.wosqualityQ3
dc.institutionauthorÇiftçioğlu E.
dc.institutionauthorÇiftçioğlu, Elif
dc.language.isoen
dc.publisherSpringeren_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectComputational fluid dynamicsen_US
dc.subjectInternal root resorptionen_US
dc.subjectIrrigationen_US
dc.subjectNeedlesen_US
dc.subjectUltrasonic irrigationen_US
dc.titleIrrigant flow characteristics in the root canal with internal root resorption: a computational fluid dynamics evaluationen_US
dc.typeArticleen_US
dspace.entity.typePublication
relation.isAuthorOfPublicationc0543e5b-c131-45fb-99fb-630826509c32
relation.isAuthorOfPublication.latestForDiscoveryc0543e5b-c131-45fb-99fb-630826509c32
relation.isOrgUnitOfPublication12d91e70-c492-45ba-9d89-68db471280b9
relation.isOrgUnitOfPublication.latestForDiscovery12d91e70-c492-45ba-9d89-68db471280b9

Files