The Influence of Interimplant Distance in Mandibular Overdentures Supported by Two Implants on Patient Satisfaction and Quality of Life

dc.authoridGECKILI, ONUR/0000-0002-7852-3915
dc.authoridBilmenoglu, Caglar/0000-0002-2580-9899
dc.authoridBilhan, Hakan/0000-0003-1787-3003
dc.authoridCilingir, Altug/0000-0002-0694-5772
dc.authorscopusid15135391400
dc.authorscopusid14012620400
dc.authorscopusid57197293393
dc.authorscopusid56564008900
dc.authorscopusid54880603900
dc.authorscopusid56563983600
dc.authorscopusid56563983600
dc.authorwosidGECKILI, ONUR/AAD-4973-2020
dc.authorwosidBilmenoglu, Caglar/HGE-5706-2022
dc.authorwosidozdiler, arda/U-1599-2018
dc.authorwosidCilingir, Altug/N-2262-2018
dc.contributor.authorGeckili, Onur
dc.contributor.authorCilingir, Altug
dc.contributor.authorErdogan, Ozge
dc.contributor.authorKesoglu, Aysun Coskun
dc.contributor.authorBilmenoglu, Caglar
dc.contributor.authorOzdiler, Arda
dc.contributor.authorBilhan, Hakan
dc.date.accessioned2024-05-25T11:18:01Z
dc.date.available2024-05-25T11:18:01Z
dc.date.issued2015
dc.departmentOkan Universityen_US
dc.department-temp[Geckili, Onur; Erdogan, Ozge; Kesoglu, Aysun Coskun; Bilmenoglu, Caglar; Ozdiler, Arda] Istanbul Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey; [Cilingir, Altug] Trakya Univ, Dept Prosthodont, Fac Dent, Edirne, Turkey; [Bilhan, Hakan] Okan Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkeyen_US
dc.descriptionGECKILI, ONUR/0000-0002-7852-3915; Bilmenoglu, Caglar/0000-0002-2580-9899; Bilhan, Hakan/0000-0003-1787-3003; Cilingir, Altug/0000-0002-0694-5772en_US
dc.description.abstractThis study evaluates the influence of interimplant distance (ID) on patient satisfaction and quality of life (QOL) of 55 patients who received mandibular overdentures supported by two implants. IDs were measured over the residual ridge crest and linearly on all of the patients' mandibular casts. The crestal detours of all patients were determined by subtracting these two values from each other. Higher IDs were associated with better QOL scores (P < .05), whereas higher crestal detour values were associated with better general comfort, chewing, ease of hygiene maintenance, esthetics, pain, and QOL scores (P < .05).en_US
dc.identifier.citation9
dc.identifier.doi10.11607/ijp.3994
dc.identifier.endpage21en_US
dc.identifier.issn0893-2174
dc.identifier.issn1942-4426
dc.identifier.issue1en_US
dc.identifier.pmid25588167
dc.identifier.scopus2-s2.0-84925282946
dc.identifier.scopusqualityQ2
dc.identifier.startpage19en_US
dc.identifier.urihttps://doi.org/10.11607/ijp.3994
dc.identifier.urihttps://hdl.handle.net/20.500.14517/279
dc.identifier.volume28en_US
dc.identifier.wosWOS:000348489100004
dc.identifier.wosqualityQ3
dc.language.isoen
dc.publisherQuintessence Publishing Co incen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subject[No Keyword Available]en_US
dc.titleThe Influence of Interimplant Distance in Mandibular Overdentures Supported by Two Implants on Patient Satisfaction and Quality of Lifeen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files