Evaluation of Surface Change and Roughness in Implants Lost Due to Peri-Implantitis Using Erbium Laser and Various Methods: An In Vitro Study

dc.authoridkocak-oztug, necla asli/0000-0003-2513-6345
dc.authoridAYKOL SAHIN, GÖKÇE/0000-0001-7644-6349
dc.authoridBaser, Ulku/0000-0002-9754-2142
dc.authoridSecgin Atar, Aslihan/0000-0001-6705-4271
dc.authorscopusid57280350300
dc.authorscopusid57192948509
dc.authorscopusid57222119853
dc.authorscopusid59043769300
dc.authorscopusid6507044993
dc.authorscopusid35239465300
dc.authorwosidkocak-oztug, necla asli/AAU-5553-2020
dc.authorwosidAYKOL SAHIN, GÖKÇE/GXH-8379-2022
dc.authorwosidYalcin, Funda/AAC-8742-2020
dc.authorwosidatar, aslıhan seçgin/AAS-6180-2020
dc.authorwosidBaser, Ulku/AAC-6731-2020
dc.contributor.authorAykol Şahin, Gökçe
dc.contributor.authorAykol-Sahin, Gokce
dc.contributor.authorKocak-Oztug, Necla Asli
dc.contributor.authorYalcin, Funda
dc.contributor.authorGokbuget, Aslan
dc.contributor.authorBaser, Ulku
dc.contributor.otherPeriodontoloji / Periodontology
dc.date.accessioned2024-05-25T11:26:37Z
dc.date.available2024-05-25T11:26:37Z
dc.date.issued2021
dc.departmentOkan Universityen_US
dc.department-temp[Secgin-Atar, Aslihan; Kocak-Oztug, Necla Asli; Yalcin, Funda; Baser, Ulku] Istanbul Univ, Fac Dent, Periodontol Dept, TR-34452 Istanbul, Turkey; [Aykol-Sahin, Gokce] Istanbul Okan Univ, Fac Dent, Dept Periodontol, TR-34959 Istanbul, Turkeyen_US
dc.descriptionkocak-oztug, necla asli/0000-0003-2513-6345; AYKOL SAHIN, GÖKÇE/0000-0001-7644-6349; Baser, Ulku/0000-0002-9754-2142; Secgin Atar, Aslihan/0000-0001-6705-4271en_US
dc.description.abstractThe aim of our study was to obtain similar surface properties and elemental composition to virgin implants after debridement of contaminated titanium implant surfaces covered with debris. Erbium-doped:yttrium, aluminum, and garnet (Er:YAG) laser, erbium, chromium-doped:yttrium, scandium, gallium, and garnet (Er,Cr:YSGG) laser, curette, and ultrasonic device were applied to contaminated implant surfaces. Scanning electron microscopy (SEM) images were taken, the elemental profile of the surfaces was evaluated with energy dispersive X-ray spectroscopy (EDX), and the surface roughness was analyzed with profilometry. Twenty-eight failed implants and two virgin implants as control were included in the study. The groups were designed accordingly; titanium curette group, ultrasonic scaler with polyetheretherketone (PEEK) tip, Er: YAG very short pulse laser group (100 mu s, 120 mJ/pulse 10 Hz), Er: YAG short-pulse laser group (300 mu s, 120 mJ/pulse, 10 Hz), Er: YAG long-pulse laser group (600 mu s, 120 mJ/pulse, 10 Hz), Er, Cr: YSGG1 laser group (1 W 10 Hz), Er, Cr: YSGG2 laser group (1.5 W, 30 Hz). In each group, four failed implants were debrided for 120 s. When SEM images and EDX findings and profilometry results were evaluated together, Er: YAG long pulse and ultrasonic groups were found to be the most effective for debridement. Furthermore, the two interventions have shown the closest topography of the sandblasted, large grit, acid-etched implant surface (SLA) as seen on virgin implants.en_US
dc.description.sponsorshipScientific Research Projects Coordination Unit of Istanbul University [TDH-2020-37077]en_US
dc.description.sponsorshipThis research was funded by the Scientific Research Projects Coordination Unit of Istanbul University, Grant No. TDH-2020-37077.en_US
dc.identifier.citation6
dc.identifier.doi10.3390/nano11102602
dc.identifier.issn2079-4991
dc.identifier.issue10en_US
dc.identifier.pmid34685043
dc.identifier.scopus2-s2.0-85116092449
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.3390/nano11102602
dc.identifier.urihttps://hdl.handle.net/20.500.14517/999
dc.identifier.volume11en_US
dc.identifier.wosWOS:000713188400001
dc.identifier.wosqualityQ1
dc.language.isoen
dc.publisherMdpien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectdental implantsen_US
dc.subjecttitaniumen_US
dc.subjectlaser therapyen_US
dc.subjectperi-implantitisen_US
dc.subjectdebridementen_US
dc.titleEvaluation of Surface Change and Roughness in Implants Lost Due to Peri-Implantitis Using Erbium Laser and Various Methods: An In Vitro Studyen_US
dc.typeArticleen_US
dspace.entity.typePublication
relation.isAuthorOfPublication25af49ce-8085-4498-83aa-24d0452b66f3
relation.isAuthorOfPublication.latestForDiscovery25af49ce-8085-4498-83aa-24d0452b66f3
relation.isOrgUnitOfPublication3815fc64-47c0-48f5-9b04-f48690b08270
relation.isOrgUnitOfPublication.latestForDiscovery3815fc64-47c0-48f5-9b04-f48690b08270

Files