Comparative Ex Vivo Evaluation of Two Electronic Percussive Testing Devices Measuring the Stability of Dental Implants

dc.authoridBilmenoglu, Caglar/0000-0002-2580-9899
dc.authoridGECKILI, ONUR/0000-0002-7852-3915
dc.authoridBilhan, Hakan/0000-0003-1787-3003
dc.authoridCilingir, Altug/0000-0002-0694-5772
dc.authorscopusid15135391400
dc.authorscopusid35267920900
dc.authorscopusid14012620400
dc.authorscopusid54880603900
dc.authorscopusid55839290100
dc.authorscopusid56436890900
dc.authorscopusid56436890900
dc.authorwosidBURAL, HAYRUNNİSA CANAN/AAE-1151-2020
dc.authorwosidBilmenoglu, Caglar/HGE-5706-2022
dc.authorwosidGECKILI, ONUR/AAD-4973-2020
dc.authorwosidAtes, Gokcen/AAR-9995-2021
dc.authorwosidCilingir, Altug/N-2262-2018
dc.contributor.authorGeckili, Onur
dc.contributor.authorBilhan, Hakan
dc.contributor.authorCilingir, Altug
dc.contributor.authorBilmenoglu, Caglar
dc.contributor.authorAtes, Gokcen
dc.contributor.authorUrgun, Aliye Ceren
dc.contributor.authorBural, Canan
dc.date.accessioned2024-05-25T11:20:47Z
dc.date.available2024-05-25T11:20:47Z
dc.date.issued2014
dc.departmentOkan Universityen_US
dc.department-temp[Geckili, Onur; Bilmenoglu, Caglar; Ates, Gokcen; Urgun, Aliye Ceren; Bural, Canan] Istanbul Univ, Fac Dent, Dept Prosthodont, Capa, Turkey; [Bilhan, Hakan] Okan Univ, Fac Dent, Dept Prosthodont, Tuzla Istanbul, Turkey; [Cilingir, Altug] Trakya Univ, Fac Dent, Dept Prosthodont, Edirne, Turkeyen_US
dc.descriptionBilmenoglu, Caglar/0000-0002-2580-9899; GECKILI, ONUR/0000-0002-7852-3915; Bilhan, Hakan/0000-0003-1787-3003; Cilingir, Altug/0000-0002-0694-5772en_US
dc.description.abstractBackground: A comparative ex vivo study was performed to determine electronic percussive test values (PTVs) measured by cabled and wireless electronic percussive testing (EPT) devices and to evaluate the intra-and interobserver reliability of the wireless EPT device. Methods: Forty implants were inserted into the vertebrae and forty into the pelvis of a steer, a safe distance apart. The implants were all 4.3 mm wide and 13 mm long, from the same manufacturer. PTV of each implant was measured by four different examiners, using both EPT devices, and compared. Additionally, the intra-and interobserver reliability of the wireless EPT device was evaluated. Results: Statistically significant differences (P < 0.05) were observed between PTVs made by the two EPT devices. PTVs measured by the wireless EPT device were significantly higher than the cabled EPT device (P < 0.05), indicating lower implant stability. The intraobserver reliability of the wireless EPT device was evaluated as excellent for the measurements in type II bone and good-to-excellent in type IV bone; interobserver reliability was evaluated as fair-to-good in both bone types. Conclusion: The wireless EPT device gives PTVs higher than the cabled EPT device, indicating lower implant stability, and its inter-and intraobserver reliability is good and acceptable.en_US
dc.description.sponsorshipResearch Fund of Istanbul University [30813]en_US
dc.description.sponsorshipThis study was financially supported and approved by the Research Fund of Istanbul University, project no. 30813. The authors report no conflicts of interest related to this study.en_US
dc.identifier.citation14
dc.identifier.doi10.1902/jop.2014.140206
dc.identifier.endpage1791en_US
dc.identifier.issn0022-3492
dc.identifier.issn1943-3670
dc.identifier.issue12en_US
dc.identifier.pmid25269525
dc.identifier.scopus2-s2.0-84914141499
dc.identifier.scopusqualityQ1
dc.identifier.startpage1786en_US
dc.identifier.urihttps://doi.org/10.1902/jop.2014.140206
dc.identifier.urihttps://hdl.handle.net/20.500.14517/534
dc.identifier.volume85en_US
dc.identifier.wosWOS:000345744300020
dc.identifier.wosqualityQ1
dc.language.isoen
dc.publisherAmer Acad Periodontologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDental implantsen_US
dc.subjectdentistryen_US
dc.subjectjaw, edentulousen_US
dc.subjectosseointegrationen_US
dc.subjectreproducibility of resultsen_US
dc.subjectresearch designen_US
dc.titleComparative Ex Vivo Evaluation of Two Electronic Percussive Testing Devices Measuring the Stability of Dental Implantsen_US