Comparative Ex Vivo Evaluation of Two Electronic Percussive Testing Devices Measuring the Stability of Dental Implants
dc.authorid | Bilmenoglu, Caglar/0000-0002-2580-9899 | |
dc.authorid | GECKILI, ONUR/0000-0002-7852-3915 | |
dc.authorid | Bilhan, Hakan/0000-0003-1787-3003 | |
dc.authorid | Cilingir, Altug/0000-0002-0694-5772 | |
dc.authorscopusid | 15135391400 | |
dc.authorscopusid | 35267920900 | |
dc.authorscopusid | 14012620400 | |
dc.authorscopusid | 54880603900 | |
dc.authorscopusid | 55839290100 | |
dc.authorscopusid | 56436890900 | |
dc.authorscopusid | 56436890900 | |
dc.authorwosid | BURAL, HAYRUNNİSA CANAN/AAE-1151-2020 | |
dc.authorwosid | Bilmenoglu, Caglar/HGE-5706-2022 | |
dc.authorwosid | GECKILI, ONUR/AAD-4973-2020 | |
dc.authorwosid | Ates, Gokcen/AAR-9995-2021 | |
dc.authorwosid | Cilingir, Altug/N-2262-2018 | |
dc.contributor.author | Geckili, Onur | |
dc.contributor.author | Bilhan, Hakan | |
dc.contributor.author | Cilingir, Altug | |
dc.contributor.author | Bilmenoglu, Caglar | |
dc.contributor.author | Ates, Gokcen | |
dc.contributor.author | Urgun, Aliye Ceren | |
dc.contributor.author | Bural, Canan | |
dc.date.accessioned | 2024-05-25T11:20:47Z | |
dc.date.available | 2024-05-25T11:20:47Z | |
dc.date.issued | 2014 | |
dc.department | Okan University | en_US |
dc.department-temp | [Geckili, Onur; Bilmenoglu, Caglar; Ates, Gokcen; Urgun, Aliye Ceren; Bural, Canan] Istanbul Univ, Fac Dent, Dept Prosthodont, Capa, Turkey; [Bilhan, Hakan] Okan Univ, Fac Dent, Dept Prosthodont, Tuzla Istanbul, Turkey; [Cilingir, Altug] Trakya Univ, Fac Dent, Dept Prosthodont, Edirne, Turkey | en_US |
dc.description | Bilmenoglu, Caglar/0000-0002-2580-9899; GECKILI, ONUR/0000-0002-7852-3915; Bilhan, Hakan/0000-0003-1787-3003; Cilingir, Altug/0000-0002-0694-5772 | en_US |
dc.description.abstract | Background: A comparative ex vivo study was performed to determine electronic percussive test values (PTVs) measured by cabled and wireless electronic percussive testing (EPT) devices and to evaluate the intra-and interobserver reliability of the wireless EPT device. Methods: Forty implants were inserted into the vertebrae and forty into the pelvis of a steer, a safe distance apart. The implants were all 4.3 mm wide and 13 mm long, from the same manufacturer. PTV of each implant was measured by four different examiners, using both EPT devices, and compared. Additionally, the intra-and interobserver reliability of the wireless EPT device was evaluated. Results: Statistically significant differences (P < 0.05) were observed between PTVs made by the two EPT devices. PTVs measured by the wireless EPT device were significantly higher than the cabled EPT device (P < 0.05), indicating lower implant stability. The intraobserver reliability of the wireless EPT device was evaluated as excellent for the measurements in type II bone and good-to-excellent in type IV bone; interobserver reliability was evaluated as fair-to-good in both bone types. Conclusion: The wireless EPT device gives PTVs higher than the cabled EPT device, indicating lower implant stability, and its inter-and intraobserver reliability is good and acceptable. | en_US |
dc.description.sponsorship | Research Fund of Istanbul University [30813] | en_US |
dc.description.sponsorship | This study was financially supported and approved by the Research Fund of Istanbul University, project no. 30813. The authors report no conflicts of interest related to this study. | en_US |
dc.identifier.citation | 14 | |
dc.identifier.doi | 10.1902/jop.2014.140206 | |
dc.identifier.endpage | 1791 | en_US |
dc.identifier.issn | 0022-3492 | |
dc.identifier.issn | 1943-3670 | |
dc.identifier.issue | 12 | en_US |
dc.identifier.pmid | 25269525 | |
dc.identifier.scopus | 2-s2.0-84914141499 | |
dc.identifier.scopusquality | Q1 | |
dc.identifier.startpage | 1786 | en_US |
dc.identifier.uri | https://doi.org/10.1902/jop.2014.140206 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14517/534 | |
dc.identifier.volume | 85 | en_US |
dc.identifier.wos | WOS:000345744300020 | |
dc.identifier.wosquality | Q1 | |
dc.language.iso | en | |
dc.publisher | Amer Acad Periodontology | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Dental implants | en_US |
dc.subject | dentistry | en_US |
dc.subject | jaw, edentulous | en_US |
dc.subject | osseointegration | en_US |
dc.subject | reproducibility of results | en_US |
dc.subject | research design | en_US |
dc.title | Comparative Ex Vivo Evaluation of Two Electronic Percussive Testing Devices Measuring the Stability of Dental Implants | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |