Comparative Ex Vivo Evaluation of Two Electronic Percussive Testing Devices Measuring the Stability of Dental Implants

dc.contributor.author Geckili, Onur
dc.contributor.author Bilhan, Hakan
dc.contributor.author Cilingir, Altug
dc.contributor.author Bilmenoglu, Caglar
dc.contributor.author Ates, Gokcen
dc.contributor.author Urgun, Aliye Ceren
dc.contributor.author Bural, Canan
dc.date.accessioned 2024-05-25T11:20:47Z
dc.date.available 2024-05-25T11:20:47Z
dc.date.issued 2014
dc.description Bilmenoglu, Caglar/0000-0002-2580-9899; GECKILI, ONUR/0000-0002-7852-3915; Bilhan, Hakan/0000-0003-1787-3003; Cilingir, Altug/0000-0002-0694-5772 en_US
dc.description.abstract Background: A comparative ex vivo study was performed to determine electronic percussive test values (PTVs) measured by cabled and wireless electronic percussive testing (EPT) devices and to evaluate the intra-and interobserver reliability of the wireless EPT device. Methods: Forty implants were inserted into the vertebrae and forty into the pelvis of a steer, a safe distance apart. The implants were all 4.3 mm wide and 13 mm long, from the same manufacturer. PTV of each implant was measured by four different examiners, using both EPT devices, and compared. Additionally, the intra-and interobserver reliability of the wireless EPT device was evaluated. Results: Statistically significant differences (P < 0.05) were observed between PTVs made by the two EPT devices. PTVs measured by the wireless EPT device were significantly higher than the cabled EPT device (P < 0.05), indicating lower implant stability. The intraobserver reliability of the wireless EPT device was evaluated as excellent for the measurements in type II bone and good-to-excellent in type IV bone; interobserver reliability was evaluated as fair-to-good in both bone types. Conclusion: The wireless EPT device gives PTVs higher than the cabled EPT device, indicating lower implant stability, and its inter-and intraobserver reliability is good and acceptable. en_US
dc.description.sponsorship Research Fund of Istanbul University [30813] en_US
dc.description.sponsorship This study was financially supported and approved by the Research Fund of Istanbul University, project no. 30813. The authors report no conflicts of interest related to this study. en_US
dc.identifier.citationcount 14
dc.identifier.doi 10.1902/jop.2014.140206
dc.identifier.issn 0022-3492
dc.identifier.issn 1943-3670
dc.identifier.scopus 2-s2.0-84914141499
dc.identifier.uri https://doi.org/10.1902/jop.2014.140206
dc.identifier.uri https://hdl.handle.net/20.500.14517/534
dc.language.iso en
dc.publisher Amer Acad Periodontology en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Dental implants en_US
dc.subject dentistry en_US
dc.subject jaw, edentulous en_US
dc.subject osseointegration en_US
dc.subject reproducibility of results en_US
dc.subject research design en_US
dc.title Comparative Ex Vivo Evaluation of Two Electronic Percussive Testing Devices Measuring the Stability of Dental Implants en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.id Bilmenoglu, Caglar/0000-0002-2580-9899
gdc.author.id GECKILI, ONUR/0000-0002-7852-3915
gdc.author.id Bilhan, Hakan/0000-0003-1787-3003
gdc.author.id Cilingir, Altug/0000-0002-0694-5772
gdc.author.scopusid 15135391400
gdc.author.scopusid 35267920900
gdc.author.scopusid 14012620400
gdc.author.scopusid 54880603900
gdc.author.scopusid 55839290100
gdc.author.scopusid 56436890900
gdc.author.scopusid 56436890900
gdc.author.wosid BURAL, HAYRUNNİSA CANAN/AAE-1151-2020
gdc.author.wosid Bilmenoglu, Caglar/HGE-5706-2022
gdc.author.wosid GECKILI, ONUR/AAD-4973-2020
gdc.author.wosid Ates, Gokcen/AAR-9995-2021
gdc.author.wosid Cilingir, Altug/N-2262-2018
gdc.coar.access metadata only access
gdc.coar.type text::journal::journal article
gdc.description.department Okan University en_US
gdc.description.departmenttemp [Geckili, Onur; Bilmenoglu, Caglar; Ates, Gokcen; Urgun, Aliye Ceren; Bural, Canan] Istanbul Univ, Fac Dent, Dept Prosthodont, Capa, Turkey; [Bilhan, Hakan] Okan Univ, Fac Dent, Dept Prosthodont, Tuzla Istanbul, Turkey; [Cilingir, Altug] Trakya Univ, Fac Dent, Dept Prosthodont, Edirne, Turkey en_US
gdc.description.endpage 1791 en_US
gdc.description.issue 12 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q1
gdc.description.startpage 1786 en_US
gdc.description.volume 85 en_US
gdc.description.wosquality Q1
gdc.identifier.pmid 25269525
gdc.identifier.wos WOS:000345744300020
gdc.index.type WoS
gdc.index.type Scopus
gdc.index.type PubMed
gdc.scopus.citedcount 14
gdc.wos.citedcount 15

Files