Evaluation of bond strength of resin cement to Er:YAG laser-etched enamel and dentin after cementation of ceramic discs

dc.authoridİsmatullaev, Artur/0000-0002-0119-6821
dc.authoridIsmatullaev, Artur/0000-0002-0119-6821
dc.authoridtaşın, simge/0000-0002-0483-2520
dc.authorscopusid57000496400
dc.authorscopusid57205888500
dc.authorscopusid6603721071
dc.authorwosidİsmatullaev, Artur/ABD-4426-2021
dc.authorwosidIsmatullaev, Artur/HKP-1395-2023
dc.authorwosidtaşın, simge/AAW-6948-2021
dc.authorwosidTaşın, Simge/AAW-9341-2021
dc.contributor.authorIsmatullaev, Artur
dc.contributor.authorTasin, Simge
dc.contributor.authorUsumez, Aslihan
dc.date.accessioned2024-05-25T12:29:44Z
dc.date.available2024-05-25T12:29:44Z
dc.date.issued2021
dc.departmentOkan Universityen_US
dc.department-temp[Ismatullaev, Artur] Univ Kyrenia, Div Prosthodont, Mersin 10, Kyrenia, Northern Cyprus, Turkey; [Tasin, Simge] Univ Istanbul Okan, Div Prosthodont, Istanbul, Turkey; [Usumez, Aslihan] Dentalplus Implant Clin, Istanbul, Turkeyen_US
dc.descriptionİsmatullaev, Artur/0000-0002-0119-6821; Ismatullaev, Artur/0000-0002-0119-6821; taşın, simge/0000-0002-0483-2520;en_US
dc.description.abstractThe purpose of this study was to investigate the shear bond strength (SBS) of ceramic discs luted to differently etched enamel and dentin surfaces. Occlusal surfaces of 64 carious-free human molars and vestibule surfaces of 64 first maxillary incisors were ground to get flat superficial dentin and flattened enamel respectively. After generating 4 groups according to the surface etching method (37% orthophosphoric acid, Er:YAG laser-contact handpiece/scanning handpiece (1 or 2 times of scanning)), ceramic discs were luted to the surfaces with adhesive resin cement (Variolink N, Vivadent Ets., Schaan/Liechtenstein). After etching and cementation, thermocycling of 5000 cycles (Sd Mechatronik Gmbh, Feldkirchen-Westerham, Germany) and SBS test (Servopulser EHFFD1; Shimadzu, Kyoto, Japan) were performed respectively. The surface morphologies of 2 specimens, etched enamel and dentin, prepared for each group were examined with SEM analysis. Failure modes were determined under a USB digital microscope. Data were analyzed with one-way analysis of variance (ANOVA) and Tukey HSD test (alpha = 0.05). SBS values in dentin surfaces showed statistically significant differences (p < 0.05) among tested groups. The highest SBS among dentin groups was determined in the group which had 2 times etching by Er:YAG laser (11.42 MPa) by a scanning handpiece. No statistical differences were observed in the other dentin or enamel groups. Laser etching seems to be a viable alternative to acid etching on both enamel and dentin surfaces while double etching of dentin with a scanning handpiece can improve the adhesion.en_US
dc.identifier.citation4
dc.identifier.doi10.1007/s10103-020-03103-1
dc.identifier.endpage454en_US
dc.identifier.issn0268-8921
dc.identifier.issn1435-604X
dc.identifier.issue2en_US
dc.identifier.pmid32696424
dc.identifier.scopus2-s2.0-85088285335
dc.identifier.scopusqualityQ1
dc.identifier.startpage447en_US
dc.identifier.urihttps://doi.org/10.1007/s10103-020-03103-1
dc.identifier.urihttps://hdl.handle.net/20.500.14517/2134
dc.identifier.volume36en_US
dc.identifier.wosWOS:000551022400001
dc.identifier.wosqualityQ2
dc.language.isoen
dc.publisherSpringer London Ltden_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectEren_US
dc.subjectYAG laseren_US
dc.subjectShear bond strengthen_US
dc.subjectIPS e-max Press ceramicen_US
dc.subjectSurface treatmenten_US
dc.subjectEnamelen_US
dc.subjectDentinen_US
dc.titleEvaluation of bond strength of resin cement to Er:YAG laser-etched enamel and dentin after cementation of ceramic discsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files