Comparison of fit accuracy between conventional and CAD/CAM-fabricated band-loop space maintainers
dc.authorid | Tokuc, Muge/0000-0002-3933-9998 | |
dc.authorid | Yilmaz, Hakan/0000-0002-9564-6212 | |
dc.authorscopusid | 57210359918 | |
dc.authorscopusid | 57210447211 | |
dc.authorwosid | YILMAZ, HAKAN/JVO-9077-2024 | |
dc.authorwosid | Tokuc, Muge/GXG-4479-2022 | |
dc.authorwosid | Yilmaz, Hakan/U-1749-2018 | |
dc.contributor.author | Tokuc, Muge | |
dc.contributor.author | Yilmaz, Hakan | |
dc.contributor.other | Pedodonti / Pedodontic | |
dc.date.accessioned | 2024-05-25T11:25:40Z | |
dc.date.available | 2024-05-25T11:25:40Z | |
dc.date.issued | 2022 | |
dc.department | Okan University | en_US |
dc.department-temp | [Tokuc, Muge] Istanbul Okan Univ, Dept Pedodont, Fac Dent, Istanbul, Turkey | en_US |
dc.description | Tokuc, Muge/0000-0002-3933-9998; Yilmaz, Hakan/0000-0002-9564-6212 | en_US |
dc.description.abstract | Aim The aim of this in vitro study was to evaluate the band fit of metallic band-loop space maintainers fabricated by conventional and 3D printing technologies for clinical applications. Design Sixteen digital intraoral impressions were selected, and resin models were printed with a 3D printer. Forty band-loop space maintainers were fabricated (20 each for both the conventional and digital groups). To evaluate the band fit of conventional and CAD/CAM-fabricated space maintainers, cement space was visualized with low-viscosity condensation silicone material on resin models. Digital evaluation was carried out using dual scan method by superimposing two scans of resin models covered with or without a silicone layer on the abutment tooth. The mean quadratic deviation (root mean square, RMS) was calculated. The RMS values between the groups were evaluated with Student's t test. Statistical significance was set at p No statistical significance was found between the conventional and digital groups (p = .56). Conclusions Within the limitations of this study, the band fit of conventional and CAD/CAM-fabricated space maintainers had no difference. Future research into CAD/CAM-fabricated appliances from different perspectives such as fracture strength and patient comfort is warranted. | en_US |
dc.identifier.citation | 6 | |
dc.identifier.doi | 10.1111/ipd.12955 | |
dc.identifier.endpage | 771 | en_US |
dc.identifier.issn | 0960-7439 | |
dc.identifier.issn | 1365-263X | |
dc.identifier.issue | 5 | en_US |
dc.identifier.pmid | 35122341 | |
dc.identifier.scopus | 2-s2.0-85130440148 | |
dc.identifier.scopusquality | Q1 | |
dc.identifier.startpage | 764 | en_US |
dc.identifier.uri | https://doi.org/10.1111/ipd.12955 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14517/928 | |
dc.identifier.volume | 32 | en_US |
dc.identifier.wos | WOS:000799487100001 | |
dc.identifier.wosquality | Q1 | |
dc.institutionauthor | Tokuc M. | |
dc.institutionauthor | Tokuç, Müge | |
dc.language.iso | en | |
dc.publisher | Wiley | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | CAD | en_US |
dc.subject | CAM | en_US |
dc.subject | paediatric dentistry | en_US |
dc.subject | space maintenance | en_US |
dc.subject | three-dimensional printing | en_US |
dc.title | Comparison of fit accuracy between conventional and CAD/CAM-fabricated band-loop space maintainers | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 37e99b7d-034f-475d-aedd-b0619da19cbe | |
relation.isAuthorOfPublication.latestForDiscovery | 37e99b7d-034f-475d-aedd-b0619da19cbe | |
relation.isOrgUnitOfPublication | b1662378-060a-4555-a010-5609ada38a00 | |
relation.isOrgUnitOfPublication.latestForDiscovery | b1662378-060a-4555-a010-5609ada38a00 |