The Evaluation of the Reliability of Periotest for Implant Stability Measurements: An In Vitro Study

dc.authorid GECKILI, ONUR/0000-0002-7852-3915
dc.authorid Bilmenoglu, Caglar/0000-0002-2580-9899
dc.authorid Cilingir, Altug/0000-0002-0694-5772
dc.authorid Bilhan, Hakan/0000-0003-1787-3003
dc.authorscopusid 35267920900
dc.authorscopusid 14012620400
dc.authorscopusid 16548947000
dc.authorscopusid 54880603900
dc.authorscopusid 55880503200
dc.authorscopusid 15135391400
dc.authorwosid GECKILI, ONUR/AAD-4973-2020
dc.authorwosid BURAL, HAYRUNNİSA CANAN/AAE-1151-2020
dc.authorwosid Bilmenoglu, Caglar/HGE-5706-2022
dc.authorwosid Sakar, Olcay/AAD-4997-2020
dc.authorwosid Cilingir, Altug/N-2262-2018
dc.contributor.author Bilhan, Hakan
dc.contributor.author Cilingir, Altug
dc.contributor.author Bural, Canan
dc.contributor.author Bilmenoglu, Caglar
dc.contributor.author Sakar, Olcay
dc.contributor.author Geckili, Onur
dc.date.accessioned 2024-05-25T11:18:29Z
dc.date.available 2024-05-25T11:18:29Z
dc.date.issued 2015
dc.department Okan University en_US
dc.department-temp [Bilhan, Hakan] Okan Univ, Dept Prosthodont, Fac Dent, Istanbul, Turkey; [Cilingir, Altug; Bilmenoglu, Caglar] Trakya Univ, Dept Prosthodont, Fac Dent, Edirne, Turkey; [Bural, Canan; Sakar, Olcay; Geckili, Onur] Istanbul Univ, Dept Prosthodont, Fac Dent, Istanbul, Turkey en_US
dc.description GECKILI, ONUR/0000-0002-7852-3915; Bilmenoglu, Caglar/0000-0002-2580-9899; Cilingir, Altug/0000-0002-0694-5772; Bilhan, Hakan/0000-0003-1787-3003 en_US
dc.description.abstract Periotest (Medizintechnik Gulden, Modautal, Germany) is a widely accepted implant stability measurement method, although the reliability is not well known. The aim of this in vitro study was to investigate the reliability of the Periotest in implant stability measurements. Thirty implants were placed in 3 cow ribs. The stability of each implant was measured by insertion torque, resonance frequency analyses, and Periotest and then compared. The Periotest values (PTVs) were measured by 4 different examiners. The measurements were repeated twice in both the buccal and mesial directions, for each implant at 2-hour intervals and the intra-and interobserver reliability of Periotest was measured. Results showed that the intraobserver reliability of the Periotest was excellent for the buccal PTVs but fair to poor for the mesial PTVs. The interobserver reliability of the Periotest was excellent for the buccal PTVs but poor for the mesial PTVs. No significance was found between the PTVs and IT values (P =.803) and PTVs and ISQ values, whereas a 47.1% significant correlation was detected between the IT values and ISQ values (P =.009). The present study indicates that only Periotest measurements from buccal result in excellent intra-and interobserver reliability for the quantification of the implant stability. en_US
dc.identifier.citationcount 23
dc.identifier.doi 10.1563/AAID-JOI-D-13-00303
dc.identifier.endpage E95 en_US
dc.identifier.issn 0160-6972
dc.identifier.issn 1548-1336
dc.identifier.issue 4 en_US
dc.identifier.pmid 24593232
dc.identifier.scopus 2-s2.0-84939487548
dc.identifier.scopusquality Q2
dc.identifier.startpage E90 en_US
dc.identifier.uri https://doi.org/10.1563/AAID-JOI-D-13-00303
dc.identifier.uri https://hdl.handle.net/20.500.14517/338
dc.identifier.volume 41 en_US
dc.identifier.wos WOS:000360159000001
dc.identifier.wosquality Q4
dc.language.iso en
dc.publisher Allen Press inc en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.scopus.citedbyCount 26
dc.subject in vitro model en_US
dc.subject dental implant en_US
dc.subject statistics en_US
dc.subject Periotest en_US
dc.subject resonance frequency analysis en_US
dc.subject Osstell en_US
dc.subject insertion torque en_US
dc.subject implant stability en_US
dc.title The Evaluation of the Reliability of Periotest for Implant Stability Measurements: An In Vitro Study en_US
dc.type Article en_US
dc.wos.citedbyCount 27

Files