Determination of radiation dose from patients undergoing Tc-99m Sestamibi nuclear cardiac imaging

dc.authoridÖztürk, Hilal/0000-0003-0079-5184
dc.authoridSonmezoglu, Kerim/0000-0003-1215-5184
dc.authoridGÜNAY, Osman/0000-0003-0760-554X
dc.authoridDemir, Mustafa/0000-0002-9813-1628
dc.authorscopusid57201976778
dc.authorscopusid57205760813
dc.authorscopusid55964900500
dc.authorscopusid56755333700
dc.authorscopusid57205635020
dc.authorscopusid6602590803
dc.authorscopusid16183244900
dc.authorwosidyarar, onur/GQB-0398-2022
dc.authorwosidÖztürk, Hilal/AAL-5543-2021
dc.authorwosidkulalı özdek, feride/JKJ-2912-2023
dc.authorwosidkulalı, feride/JKJ-2869-2023
dc.authorwosidGUNDOGDU, OZCAN/F-6064-2018
dc.authorwosidYaşar, Doğan/AAB-1197-2019
dc.authorwosidGÜNAY, Osman/X-7344-2018
dc.contributor.authorGunay, O.
dc.contributor.authorSarihan, M.
dc.contributor.authorYarar, O.
dc.contributor.authorAbuqbeitah, M.
dc.contributor.authorDemir, M.
dc.contributor.authorSonmezoglu, K.
dc.contributor.authorGundogdu, O.
dc.contributor.otherRadyoterapi / Radiotherapy
dc.contributor.otherAğız ve Diş Sağlığı / Mouth and Dental Health
dc.date.accessioned2024-05-25T11:41:22Z
dc.date.available2024-05-25T11:41:22Z
dc.date.issued2019
dc.departmentOkan Universityen_US
dc.department-temp[Gunay, O.; Sarihan, M.; Yarar, O.; Ozturk, H.] Istanbul Okan Univ, Vocat Sch Hlth Serv, Istanbul, Turkey; [Gunay, O.; Gundogdu, O.] Kocaeli Univ, Fac Technol, Kocaeli, Turkey; [Abuqbeitah, M.; Demir, M.; Sonmezoglu, K.] Istanbul Univ Cerrahpasa, Cerrahpasa Fac Med, Dept Nucl Med, Istanbul, Turkey; [Abamor, E.; Kara, O. E.] Istanbul Okan Univ Hosp, Istanbul, Turkey; [Isikci, N. Ipek] Nisantasi Univ, Fac Engn & Architecture, Istanbul, Turkey; [Akozcan, S.] Kirklareli Univ, Fac Art & Sci, Kirklareli, Turkey; [Kulali, F.] Uskudar Univ, Vocat Sch Hlth Serv, Istanbul, Turkey; [Yasar, D.] Ahi Evran Univ, Fac Art & Sci, Kirsehir, Turkeyen_US
dc.descriptionÖztürk, Hilal/0000-0003-0079-5184; Sonmezoglu, Kerim/0000-0003-1215-5184; GÜNAY, Osman/0000-0003-0760-554X; Demir, Mustafa/0000-0002-9813-1628en_US
dc.description.abstractTo date, myocardial perfusion (MP) has been utilized to assess the adequacy of blood flow to the myocardium in order to determine the ischemic heart diseases. With the advent of SPECT/CT, MP became the most common investigation in the field of nuclear cardiology with more accuracy and details. Thallium-201 and Technetium-99m (Tc-99m) have been early used in cardiac nuclear imaging. Half-life of Tc-99m is 6 h, and its energy is 140 keV, while the half-life of Tl-201 is as longer as 73 h, its X-ray energies range between 69 and 81 kV in addition to gamma rays of 135 keV and 167 keV. The purpose of the present study was to explore the radiation dose rates emitted from the patients following Tc-99m sestamibi injection. To achieve that, the radiation emanated to the environment was measured at different distances from patients and various time intervals for 20 patients using GM counter. The mean radioactivity administered to the patients was 391.1 MBq (10.6 mCi), with a range between 276.8 MBq to maximum of 515.4 MBq. Radiation dose rate was found 9.07 mu Sv h(-1) at 1 m distance from the patient's chest level after 7.6 min, then decayed to 7.93 mu Sv h(-1) after 36.5 min, and 7.83 mu Sv h(-1) later to 66.4 min. It was concluded that 1 m distance from the patients sounds sensibly adequate to maintain the occupational dose within the safe limit following Tc-99m sestamibi injection, while verification of public dose rate <= 1 mu Sv h(-1) at 1 m distance from the patient prolongs to 14 h following Tc-99m injection.en_US
dc.identifier.citation4
dc.identifier.doi10.1007/s13762-019-02262-1
dc.identifier.endpage5258en_US
dc.identifier.issn1735-1472
dc.identifier.issn1735-2630
dc.identifier.issue9en_US
dc.identifier.scopus2-s2.0-85061489052
dc.identifier.scopusqualityQ2
dc.identifier.startpage5251en_US
dc.identifier.urihttps://doi.org/10.1007/s13762-019-02262-1
dc.identifier.urihttps://hdl.handle.net/20.500.14517/1516
dc.identifier.volume16en_US
dc.identifier.wosWOS:000478894500038
dc.identifier.wosqualityQ3
dc.institutionauthorSarıhan M.
dc.institutionauthorSarıhan, Mucize
dc.institutionauthorYarar, Onur
dc.language.isoen
dc.publisherSpringeren_US
dc.relation.ispartof4th International Conference on Computational and Experimental Science and Engineering (ICCESEN) -- OCT 04-08, 2017 -- Kemer, TURKEYen_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectRadiation dose rateen_US
dc.subjectTc-99men_US
dc.subjectHospital managementen_US
dc.titleDetermination of radiation dose from patients undergoing Tc-99m Sestamibi nuclear cardiac imagingen_US
dc.typeConference Objecten_US
dspace.entity.typePublication
relation.isAuthorOfPublication14d5db83-8d04-44f0-ae9c-920e4c950ffc
relation.isAuthorOfPublication7d6743e7-50e2-4896-9cda-701dd9faf7bf
relation.isAuthorOfPublication.latestForDiscovery14d5db83-8d04-44f0-ae9c-920e4c950ffc
relation.isOrgUnitOfPublicationf29867db-2526-4694-a1e4-fa036c746a81
relation.isOrgUnitOfPublication81939c7a-8e9c-49ce-93bc-c6eafcd0ed50
relation.isOrgUnitOfPublication.latestForDiscoveryf29867db-2526-4694-a1e4-fa036c746a81

Files