Comparison of the Primary Stability of Two Implant Designs in Two Different Bone Types: An In Vitro Study
dc.authorid | GECKILI, ONUR/0000-0002-7852-3915 | |
dc.authorid | Bilmenoglu, Caglar/0000-0002-2580-9899 | |
dc.authorid | Bilhan, Hakan/0000-0003-1787-3003 | |
dc.authorid | Cilingir, Altug/0000-0002-0694-5772 | |
dc.authorscopusid | 35267920900 | |
dc.authorscopusid | 54880603900 | |
dc.authorscopusid | 56436890900 | |
dc.authorscopusid | 55839290100 | |
dc.authorscopusid | 16548947000 | |
dc.authorscopusid | 14012620400 | |
dc.authorscopusid | 14012620400 | |
dc.authorwosid | GECKILI, ONUR/AAD-4973-2020 | |
dc.authorwosid | Ates, Gokcen/AAR-9995-2021 | |
dc.authorwosid | BURAL, HAYRUNNİSA CANAN/AAE-1151-2020 | |
dc.authorwosid | Bilmenoglu, Caglar/HGE-5706-2022 | |
dc.authorwosid | Cilingir, Altug/N-2262-2018 | |
dc.contributor.author | Bilhan, Hakan | |
dc.contributor.author | Bilmenoglu, Caglar | |
dc.contributor.author | Urgun, Aliye Ceren | |
dc.contributor.author | Ates, Gokcen | |
dc.contributor.author | Bural, Canan | |
dc.contributor.author | Cilingir, Altug | |
dc.contributor.author | Geckili, Onur | |
dc.date.accessioned | 2024-05-25T11:18:06Z | |
dc.date.available | 2024-05-25T11:18:06Z | |
dc.date.issued | 2015 | |
dc.department | Okan University | en_US |
dc.department-temp | [Bilhan, Hakan] Okan Univ, Dept Prosthodont, Fac Dent, Istanbul, Turkey; [Bilmenoglu, Caglar] Trakya Univ, Dept Prosthodont, Fac Dent, Edirne, Turkey; [Urgun, Aliye Ceren; Ates, Gokcen; Bural, Canan; Geckili, Onur] Istanbul Univ, Dept Prosthodont, Fac Dent, TR-34093 Istanbul, Turkey; [Cilingir, Altug] Trakya Univ, Dept Prosthodont, Fac Dent, Edirne, Turkey | en_US |
dc.description | GECKILI, ONUR/0000-0002-7852-3915; Bilmenoglu, Caglar/0000-0002-2580-9899; Bilhan, Hakan/0000-0003-1787-3003; Cilingir, Altug/0000-0002-0694-5772 | en_US |
dc.description.abstract | Purpose: Achievement of primary stability upon surgical placement of dental implants is a key factor for successful osseointegration and depends mainly on implant-related factors. The aim of this study was to compare and assess the primary stability of implants with active and regular threads in type 2 as well as type 4 bone. Materials and Methods: Fresh cow vertebrae and a pelvis were used as models of type 4 bone and type 2 bone, respectively. Implants with two different designs-regular-threaded and active-threaded-both 4.3 mm wide and 13 mm long, were placed in both types of bone (n = 80). Stability measurements were completed by four prosthodontists using two different Periotest devices and resonance frequency analysis. Statistical analyses were performed with the Mann-Whitney U test. Results: No statistically significant differences were found between the implant types in either type of bone in the stability measured with different methods. For both implant types, the mean resonance frequency values in type 2 bone were statistically significantly higher than in type 4 bone, whereas the mean Periotest values in type 2 bone were statistically significantly lower than in type 4 bone. Conclusion: Within the limitations of this in vitro study in bone types 2 and 4, the active-threaded implant, which was invented to increase primary stability, did not show higher primary stability compared to a regular-threaded implant. | en_US |
dc.description.sponsorship | Research Fund of Istanbul University [30813] | en_US |
dc.description.sponsorship | This study was financially supported and approved by the Research Fund of Istanbul University (project no. 30813). The authors reported no conflicts of interest related to this study. | en_US |
dc.identifier.citation | 13 | |
dc.identifier.doi | 10.11607/jomi.3939 | |
dc.identifier.endpage | 1040 | en_US |
dc.identifier.issn | 0882-2786 | |
dc.identifier.issn | 1942-4434 | |
dc.identifier.issue | 5 | en_US |
dc.identifier.pmid | 26394338 | |
dc.identifier.scopus | 2-s2.0-84983517120 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 1036 | en_US |
dc.identifier.uri | https://doi.org/10.11607/jomi.3939 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14517/296 | |
dc.identifier.volume | 30 | en_US |
dc.identifier.wos | WOS:000367251300006 | |
dc.identifier.wosquality | Q3 | |
dc.language.iso | en | |
dc.publisher | Quintessence Publishing Co inc | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | bone quality | en_US |
dc.subject | bone-implant interface | en_US |
dc.subject | immediate loading | en_US |
dc.subject | implant design | en_US |
dc.subject | implant stability | en_US |
dc.title | Comparison of the Primary Stability of Two Implant Designs in Two Different Bone Types: An In Vitro Study | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |