Comparison of the Primary Stability of Two Implant Designs in Two Different Bone Types: An In Vitro Study

dc.authoridGECKILI, ONUR/0000-0002-7852-3915
dc.authoridBilmenoglu, Caglar/0000-0002-2580-9899
dc.authoridBilhan, Hakan/0000-0003-1787-3003
dc.authoridCilingir, Altug/0000-0002-0694-5772
dc.authorscopusid35267920900
dc.authorscopusid54880603900
dc.authorscopusid56436890900
dc.authorscopusid55839290100
dc.authorscopusid16548947000
dc.authorscopusid14012620400
dc.authorscopusid14012620400
dc.authorwosidGECKILI, ONUR/AAD-4973-2020
dc.authorwosidAtes, Gokcen/AAR-9995-2021
dc.authorwosidBURAL, HAYRUNNİSA CANAN/AAE-1151-2020
dc.authorwosidBilmenoglu, Caglar/HGE-5706-2022
dc.authorwosidCilingir, Altug/N-2262-2018
dc.contributor.authorBilhan, Hakan
dc.contributor.authorBilmenoglu, Caglar
dc.contributor.authorUrgun, Aliye Ceren
dc.contributor.authorAtes, Gokcen
dc.contributor.authorBural, Canan
dc.contributor.authorCilingir, Altug
dc.contributor.authorGeckili, Onur
dc.date.accessioned2024-05-25T11:18:06Z
dc.date.available2024-05-25T11:18:06Z
dc.date.issued2015
dc.departmentOkan Universityen_US
dc.department-temp[Bilhan, Hakan] Okan Univ, Dept Prosthodont, Fac Dent, Istanbul, Turkey; [Bilmenoglu, Caglar] Trakya Univ, Dept Prosthodont, Fac Dent, Edirne, Turkey; [Urgun, Aliye Ceren; Ates, Gokcen; Bural, Canan; Geckili, Onur] Istanbul Univ, Dept Prosthodont, Fac Dent, TR-34093 Istanbul, Turkey; [Cilingir, Altug] Trakya Univ, Dept Prosthodont, Fac Dent, Edirne, Turkeyen_US
dc.descriptionGECKILI, ONUR/0000-0002-7852-3915; Bilmenoglu, Caglar/0000-0002-2580-9899; Bilhan, Hakan/0000-0003-1787-3003; Cilingir, Altug/0000-0002-0694-5772en_US
dc.description.abstractPurpose: Achievement of primary stability upon surgical placement of dental implants is a key factor for successful osseointegration and depends mainly on implant-related factors. The aim of this study was to compare and assess the primary stability of implants with active and regular threads in type 2 as well as type 4 bone. Materials and Methods: Fresh cow vertebrae and a pelvis were used as models of type 4 bone and type 2 bone, respectively. Implants with two different designs-regular-threaded and active-threaded-both 4.3 mm wide and 13 mm long, were placed in both types of bone (n = 80). Stability measurements were completed by four prosthodontists using two different Periotest devices and resonance frequency analysis. Statistical analyses were performed with the Mann-Whitney U test. Results: No statistically significant differences were found between the implant types in either type of bone in the stability measured with different methods. For both implant types, the mean resonance frequency values in type 2 bone were statistically significantly higher than in type 4 bone, whereas the mean Periotest values in type 2 bone were statistically significantly lower than in type 4 bone. Conclusion: Within the limitations of this in vitro study in bone types 2 and 4, the active-threaded implant, which was invented to increase primary stability, did not show higher primary stability compared to a regular-threaded implant.en_US
dc.description.sponsorshipResearch Fund of Istanbul University [30813]en_US
dc.description.sponsorshipThis study was financially supported and approved by the Research Fund of Istanbul University (project no. 30813). The authors reported no conflicts of interest related to this study.en_US
dc.identifier.citation13
dc.identifier.doi10.11607/jomi.3939
dc.identifier.endpage1040en_US
dc.identifier.issn0882-2786
dc.identifier.issn1942-4434
dc.identifier.issue5en_US
dc.identifier.pmid26394338
dc.identifier.scopus2-s2.0-84983517120
dc.identifier.scopusqualityQ2
dc.identifier.startpage1036en_US
dc.identifier.urihttps://doi.org/10.11607/jomi.3939
dc.identifier.urihttps://hdl.handle.net/20.500.14517/296
dc.identifier.volume30en_US
dc.identifier.wosWOS:000367251300006
dc.identifier.wosqualityQ3
dc.language.isoen
dc.publisherQuintessence Publishing Co incen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectbone qualityen_US
dc.subjectbone-implant interfaceen_US
dc.subjectimmediate loadingen_US
dc.subjectimplant designen_US
dc.subjectimplant stabilityen_US
dc.titleComparison of the Primary Stability of Two Implant Designs in Two Different Bone Types: An In Vitro Studyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files