Comparison of the use of piezosurgery expander and conventional instruments on primary implant stability

dc.authoridErdogan, Ozgur/0000-0003-1547-2513
dc.authorscopusid55903369400
dc.authorscopusid36916526700
dc.authorwosidmercan, ümit/AAM-7482-2021
dc.contributor.authorMercan, U.
dc.contributor.authorErdogan, O.
dc.contributor.otherAğız,Diş ve Çene Cerrahisi / Oral, Dental and Maxillofacial Surgery
dc.date.accessioned2024-05-25T12:30:14Z
dc.date.available2024-05-25T12:30:14Z
dc.date.issued2020
dc.departmentOkan Universityen_US
dc.department-temp[Mercan, U.; Erdogan, O.] Okan Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Gulbahar Mh Oya Sok 23-A, TR-34394 Istanbul, Turkeyen_US
dc.descriptionErdogan, Ozgur/0000-0003-1547-2513en_US
dc.description.abstractObjective: To compare the use of a piezosurgery expander and conventional chisel/osteotome on primary implant stability. Materials and Methods: Twenty fresh ribs were divided into two main groups; group P and group C. In group P, bone expansion was performed using piezosurgery. In group C, bone expansion was performed using conventional chisel osteotomy. In both groups, the implants were inserted into the ribs after bone expansion. After implant placement, primary stability values were evaluated from the bucco-lingual (B-L) and mesio-distal (M-D) sides of the implant. Results: The primary stability values on the B-L side of both implants in group P were significantly higher than in group C (P < 0.05). Conclusion: The use of piezo-expanders in the alveolar split technique has better effects on primary implant stability compared with the conventional technique.en_US
dc.identifier.citation1
dc.identifier.doi10.4103/njcp.njcp_132_20
dc.identifier.endpage1522en_US
dc.identifier.issn1119-3077
dc.identifier.issue11en_US
dc.identifier.pmid33221775
dc.identifier.scopus2-s2.0-85096631666
dc.identifier.scopusqualityQ2
dc.identifier.startpage1517en_US
dc.identifier.urihttps://doi.org/10.4103/njcp.njcp_132_20
dc.identifier.urihttps://hdl.handle.net/20.500.14517/2188
dc.identifier.volume23en_US
dc.identifier.wosWOS:000617096500006
dc.identifier.wosqualityQ4
dc.institutionauthorErdoğan, Özgür
dc.language.isoen
dc.publisherWolters Kluwer Medknow Publicationsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAlveolar ridge spliten_US
dc.subjectimplanten_US
dc.subjectpiezosurgery expanderen_US
dc.subjectprimary stabilityen_US
dc.titleComparison of the use of piezosurgery expander and conventional instruments on primary implant stabilityen_US
dc.typeArticleen_US
dspace.entity.typePublication
relation.isAuthorOfPublication38e20b08-51c2-425d-8181-750923c8a565
relation.isAuthorOfPublication.latestForDiscovery38e20b08-51c2-425d-8181-750923c8a565
relation.isOrgUnitOfPublication9d7f58b2-6caf-4591-83fc-e79c39a149f4
relation.isOrgUnitOfPublication.latestForDiscovery9d7f58b2-6caf-4591-83fc-e79c39a149f4

Files