Shear strengthening of reinforced concrete T-beams with fully or partially bonded fibre-reinforced polymer composites

dc.authoridErdogan, Hakan/0000-0002-7241-7652
dc.authorscopusid15058124900
dc.authorscopusid41561085300
dc.authorscopusid16027722900
dc.authorscopusid7006831787
dc.authorscopusid56194199300
dc.authorwosidErdogan, Hakan/F-5961-2018
dc.authorwosidAtalay, Hilal Meydanli/J-5159-2012
dc.authorwosidAKPINAR, Erkan/F-6856-2018
dc.authorwosidErdogan, Hakan/AAR-6683-2020
dc.contributor.authorOzden, Sevket
dc.contributor.authorAtalay, Hilal M.
dc.contributor.authorAkpinar, Erkan
dc.contributor.authorErdogan, Hakan
dc.contributor.authorVulas, Yilmaz Zafer
dc.date.accessioned2024-05-25T11:24:10Z
dc.date.available2024-05-25T11:24:10Z
dc.date.issued2014
dc.departmentOkan Universityen_US
dc.department-temp[Ozden, Sevket] Okan Univ, Fac Engn & Architecture, Dept Civil Engn, TR-34959 Tuzla Istanbul, Turkey; [Atalay, Hilal M.; Akpinar, Erkan; Erdogan, Hakan] Kocaeli Univ, Fac Engn, Dept Civil Engn, TR-41380 Kocaeli, Turkey; [Vulas, Yilmaz Zafer] Polisan Holding Co, Project & Maintenance Dept, TR-41455 Dilovasi Kocaeli, Turkeyen_US
dc.descriptionErdogan, Hakan/0000-0002-7241-7652en_US
dc.description.abstractA series of 10 reinforced concrete T-beams, designed deficient in shear, were tested in order to investigate the shear performance achieved through externally applied U-shaped FRP composite strips. Key variables of the study were: type of FRP composite, type of surface bonding and type of end anchorage for the strips. Carbon fibre-reinforced polymer (CFRP), glass fibre-reinforced polymer (GFRP) and high modulus of elasticity carbon fibre-reinforced polymer (Hi-CFRP) strips were the special composite types with different elastic moduli, full or partial bonding of the strips to the beam surface were the variables for the type of surface bonding. All partially bonded FRP strips were free from surface bonding, whereas epoxy-bonded FRP anchors were used at their ends close to the slab-to-beam connection. Those strips with full surface bonding have either epoxy-bonded FRP anchors at their ends or the strip ends were without anchorage. The test results revealed that shear-deficient beams may well be strengthened by the externally applied FRP strips. However, the level of strength enhancement and the failure pattern is closely influenced by the composite's elastic modulus, the type of surface bonding and the type of end anchorage for the FRP strip itself. The enhancement of the Hi-CFRP strips did not live up to expectations. The use of unbonded FRP for shear strengthening yielded promising results.en_US
dc.identifier.citation49
dc.identifier.doi10.1002/suco.201300031
dc.identifier.endpage239en_US
dc.identifier.issn1464-4177
dc.identifier.issn1751-7648
dc.identifier.issue2en_US
dc.identifier.scopus2-s2.0-84901837082
dc.identifier.scopusqualityQ2
dc.identifier.startpage229en_US
dc.identifier.urihttps://doi.org/10.1002/suco.201300031
dc.identifier.urihttps://hdl.handle.net/20.500.14517/779
dc.identifier.volume15en_US
dc.identifier.wosWOS:000337507200012
dc.identifier.wosqualityQ2
dc.language.isoen
dc.publisherErnst & Sohnen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectreinforced concreteen_US
dc.subjectbeam shear strengtheningen_US
dc.subjectfibre-reinforced polymeren_US
dc.subjectanchorageen_US
dc.subjectpartially bonded FRPen_US
dc.subjectmodulus of elasticityen_US
dc.subjectcompositeen_US
dc.titleShear strengthening of reinforced concrete T-beams with fully or partially bonded fibre-reinforced polymer compositesen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files