Effect of thermocycling on the surface properties of CAD-CAM denture base materials after different surface treatments

dc.authoridFonseca, Manrique/0000-0003-4267-0515
dc.authoridSchimmel, Martin/0000-0001-9700-5534
dc.authoridCakmak, Gulce/0000-0003-1751-9207
dc.authorscopusid57224805406
dc.authorscopusid57217863941
dc.authorscopusid57204883280
dc.authorscopusid24485630400
dc.authorscopusid35583824600
dc.authorwosidCakmak, Gulce/GRE-6472-2022
dc.authorwosidatalay, sevda/AFQ-2553-2022
dc.authorwosidFonseca, Manrique/ABF-6644-2021
dc.authorwosidSchimmel, Martin/F-5694-2011
dc.authorwosidÇAKMAK, GONCA/C-6464-2018
dc.contributor.authorAtalay, Sevda
dc.contributor.authorCakmak, Guelce
dc.contributor.authorFonseca, Manrique
dc.contributor.authorSchimmel, Martin
dc.contributor.authorYilmaz, Burak
dc.date.accessioned2024-05-25T11:42:45Z
dc.date.available2024-05-25T11:42:45Z
dc.date.issued2021
dc.departmentOkan Universityen_US
dc.department-temp[Atalay, Sevda] Istanbul Okan Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey; [Cakmak, Guelce; Fonseca, Manrique; Schimmel, Martin; Yilmaz, Burak] Univ Bern, Dept Reconstruct Dent & Gerodontol, Sch Dent Med, Freiburgstr 7, CH-3010 Bern, Switzerland; [Schimmel, Martin] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland; [Yilmaz, Burak] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland; [Yilmaz, Burak] Ohio State Univ, Div Restorat & Prosthet Dent, Columbus, OH 43210 USAen_US
dc.descriptionFonseca, Manrique/0000-0003-4267-0515; Schimmel, Martin/0000-0001-9700-5534; Cakmak, Gulce/0000-0003-1751-9207en_US
dc.description.abstractPurpose: To evaluate the effect of thermocycling on the water contact angle (WCA), surface roughness (SR), and microhardness (MH) of different CAD-CAM PMMA denture base materials after different surface treatments (conventional laboratory polishing, polishing kit, or surface sealant). Materials and methods: Disk-shaped specimens (10 & times; 2 mm) of 3 different CAD-CAM PMMAs, AvaDent (AV); Merz M-PM (M-PM); Polident (Poli), and a conventional heat-polymerized PMMA (Vynacron) (CV) (n=21) were divided into 3 different surface treatment groups (n=7): conventional laboratory polishing (CLP), polishing with acrylic resin polisher kit (PK), and a surface sealant (Palaseal) (SSC). Stereomicroscopic images were taken both before and after thermocycling. WCA, SR, and MH of all specimens were measured before and after thermocycling and compared by using a 2-way ANOVA (alpha=0.05). Results: After thermocycling, WCA significantly increased for CLP- or PK -applied (P<.001) specimens of all materials and SSC-applied M-PM (P=.002), SR significantly increased for CLP-applied M-PM (P=.027) and PKapplied Poli (P=.041), and MH significantly decreased for CLP- or PK-applied AV (P = .001, P < .001, respectively), CV (P=.033, P=.023, respectively), and M-PM (P=.003, P=.001, respectively), SSC-applied M-PM (P<.001), and CLP-applied Poli (P<.001). Stereomicroscopic images revealed rougher surfaces for PK-applied specimens. Conclusions: After thermocycling, surface treatment had a significant effect on water contact angle and surface roughness. CLP or PK application resulted in hydrophobic surfaces compared with before thermocycling. CLP or SSC application on CAD-CAM PMMAs resulted in smoother surfaces. Thermocycling lowered the microhardness of all PMMAs, and the decrease was significant in CLP- or PK-applied PMMAs, except for PK-applied Poli.en_US
dc.identifier.citation23
dc.identifier.doi10.1016/j.jmbbm.2021.104646
dc.identifier.issn1751-6161
dc.identifier.issn1878-0180
dc.identifier.pmid34166873
dc.identifier.scopus2-s2.0-85108364965
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1016/j.jmbbm.2021.104646
dc.identifier.urihttps://hdl.handle.net/20.500.14517/1634
dc.identifier.volume121en_US
dc.identifier.wosWOS:000674521700002
dc.identifier.wosqualityQ2
dc.language.isoen
dc.publisherElsevieren_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCAD-CAM materialsen_US
dc.subjectPMMA denturesen_US
dc.subjectMicrohardnessen_US
dc.subjectSurface roughnessen_US
dc.subjectThermocyclingen_US
dc.subjectWater contact angleen_US
dc.titleEffect of thermocycling on the surface properties of CAD-CAM denture base materials after different surface treatmentsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files