Effect of thermocycling on the surface properties of CAD-CAM denture base materials after different surface treatments
dc.authorid | Fonseca, Manrique/0000-0003-4267-0515 | |
dc.authorid | Schimmel, Martin/0000-0001-9700-5534 | |
dc.authorid | Cakmak, Gulce/0000-0003-1751-9207 | |
dc.authorscopusid | 57224805406 | |
dc.authorscopusid | 57217863941 | |
dc.authorscopusid | 57204883280 | |
dc.authorscopusid | 24485630400 | |
dc.authorscopusid | 35583824600 | |
dc.authorwosid | Cakmak, Gulce/GRE-6472-2022 | |
dc.authorwosid | atalay, sevda/AFQ-2553-2022 | |
dc.authorwosid | Fonseca, Manrique/ABF-6644-2021 | |
dc.authorwosid | Schimmel, Martin/F-5694-2011 | |
dc.authorwosid | ÇAKMAK, GONCA/C-6464-2018 | |
dc.contributor.author | Atalay, Sevda | |
dc.contributor.author | Cakmak, Guelce | |
dc.contributor.author | Fonseca, Manrique | |
dc.contributor.author | Schimmel, Martin | |
dc.contributor.author | Yilmaz, Burak | |
dc.date.accessioned | 2024-05-25T11:42:45Z | |
dc.date.available | 2024-05-25T11:42:45Z | |
dc.date.issued | 2021 | |
dc.department | Okan University | en_US |
dc.department-temp | [Atalay, Sevda] Istanbul Okan Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey; [Cakmak, Guelce; Fonseca, Manrique; Schimmel, Martin; Yilmaz, Burak] Univ Bern, Dept Reconstruct Dent & Gerodontol, Sch Dent Med, Freiburgstr 7, CH-3010 Bern, Switzerland; [Schimmel, Martin] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland; [Yilmaz, Burak] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland; [Yilmaz, Burak] Ohio State Univ, Div Restorat & Prosthet Dent, Columbus, OH 43210 USA | en_US |
dc.description | Fonseca, Manrique/0000-0003-4267-0515; Schimmel, Martin/0000-0001-9700-5534; Cakmak, Gulce/0000-0003-1751-9207 | en_US |
dc.description.abstract | Purpose: To evaluate the effect of thermocycling on the water contact angle (WCA), surface roughness (SR), and microhardness (MH) of different CAD-CAM PMMA denture base materials after different surface treatments (conventional laboratory polishing, polishing kit, or surface sealant). Materials and methods: Disk-shaped specimens (10 & times; 2 mm) of 3 different CAD-CAM PMMAs, AvaDent (AV); Merz M-PM (M-PM); Polident (Poli), and a conventional heat-polymerized PMMA (Vynacron) (CV) (n=21) were divided into 3 different surface treatment groups (n=7): conventional laboratory polishing (CLP), polishing with acrylic resin polisher kit (PK), and a surface sealant (Palaseal) (SSC). Stereomicroscopic images were taken both before and after thermocycling. WCA, SR, and MH of all specimens were measured before and after thermocycling and compared by using a 2-way ANOVA (alpha=0.05). Results: After thermocycling, WCA significantly increased for CLP- or PK -applied (P<.001) specimens of all materials and SSC-applied M-PM (P=.002), SR significantly increased for CLP-applied M-PM (P=.027) and PKapplied Poli (P=.041), and MH significantly decreased for CLP- or PK-applied AV (P = .001, P < .001, respectively), CV (P=.033, P=.023, respectively), and M-PM (P=.003, P=.001, respectively), SSC-applied M-PM (P<.001), and CLP-applied Poli (P<.001). Stereomicroscopic images revealed rougher surfaces for PK-applied specimens. Conclusions: After thermocycling, surface treatment had a significant effect on water contact angle and surface roughness. CLP or PK application resulted in hydrophobic surfaces compared with before thermocycling. CLP or SSC application on CAD-CAM PMMAs resulted in smoother surfaces. Thermocycling lowered the microhardness of all PMMAs, and the decrease was significant in CLP- or PK-applied PMMAs, except for PK-applied Poli. | en_US |
dc.identifier.citation | 23 | |
dc.identifier.doi | 10.1016/j.jmbbm.2021.104646 | |
dc.identifier.issn | 1751-6161 | |
dc.identifier.issn | 1878-0180 | |
dc.identifier.pmid | 34166873 | |
dc.identifier.scopus | 2-s2.0-85108364965 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.uri | https://doi.org/10.1016/j.jmbbm.2021.104646 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14517/1634 | |
dc.identifier.volume | 121 | en_US |
dc.identifier.wos | WOS:000674521700002 | |
dc.identifier.wosquality | Q2 | |
dc.language.iso | en | |
dc.publisher | Elsevier | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | CAD-CAM materials | en_US |
dc.subject | PMMA dentures | en_US |
dc.subject | Microhardness | en_US |
dc.subject | Surface roughness | en_US |
dc.subject | Thermocycling | en_US |
dc.subject | Water contact angle | en_US |
dc.title | Effect of thermocycling on the surface properties of CAD-CAM denture base materials after different surface treatments | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |