Effect of attachment types and number of implants supporting mandibular overdentures on stress distribution: A computed tomography-based 3D finite element analysis
No Thumbnail Available
Date
2015
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier Sci Ltd
Open Access Color
OpenAIRE Downloads
OpenAIRE Views
Abstract
The objective of this study was to calculate stresses in bone tissue surrounding uncoupled and splinted implants that are induced by a bite force applied to the mandible and to determine whether the number of mandibular overdenture supporting implants in mandibular bone influence the stress distribution. A human adult edentulous mandible retrieved from a formalin fixed cadaver was used to define the geometry of finite element (FE) model and the FE model was verified with experimental measurements. Following the FE model validation, three different biting situations were simulated for the 2-, 3- and 4-implant retentive anchor as well as bar attachment overdentures under vertical loading of 100 N. As a result of the analyses, it was concluded that an increment in implant number and the splinted attachment type tended to cause lower stresses and the use of two single attachments seems to be a safe and sufficient solution for the treatment of mandibular edentulism with overdentures. (C) 2014 Elsevier Ltd. All rights reserved.
Description
Muğan, Ata/0000-0002-5293-7562; Baykasoğlu, Cengiz/0000-0001-7583-7655; Mugan, Ata/0000-0002-5293-7562; Bilhan, Hakan/0000-0003-1787-3003
Keywords
Mandibular overdenture, Finite element analysis, Attachment type, Number of implants, Stress distribution, Biomechanics
Turkish CoHE Thesis Center URL
Fields of Science
Citation
38
WoS Q
Q3
Scopus Q
Q2
Source
Volume
48
Issue
1
Start Page
130
End Page
137