Validity and Reliability of a Revised Northampton Neonatal Skin Assessment Tool in Turkish Language

dc.authorscopusid57090414300
dc.authorscopusid57191618843
dc.authorscopusid55521560100
dc.authorscopusid55000107500
dc.authorscopusid55320030400
dc.authorscopusid8604063700
dc.authorwosidUysal, Gülzade/GZA-7199-2022
dc.authorwosidSönmez Düzkaya, Duygu/HHS-4528-2022
dc.authorwosidKarakoc, Ayse/Y-2210-2019
dc.authorwosidSönmez Düzkaya, Duygu/V-5305-2017
dc.contributor.authorKarakoc, Ayse
dc.contributor.authorDuzkaya, Duygu Sonmez
dc.contributor.authorTemizsoy, Ebru
dc.contributor.authorKaraca, Semra
dc.contributor.authorUysal, Gulzade
dc.contributor.authorCangur, Sengul
dc.date.accessioned2024-05-25T11:20:24Z
dc.date.available2024-05-25T11:20:24Z
dc.date.issued2017
dc.departmentOkan Universityen_US
dc.department-temp[Karakoc, Ayse; Karaca, Semra] Marmara Univ, Fac Hlth Sci, Istanbul, Turkey; [Duzkaya, Duygu Sonmez] Istanbul Univ, Istanbul Fac Med, Directorate Nursing Serv, Istanbul, Turkey; [Temizsoy, Ebru] Zeynep Kamil Obstet & Pediat Dis Training & Res H, Minist Hlth, Istanbul, Turkey; [Uysal, Gulzade] Okan Univ, Fac Hlth Sci, Istanbul, Turkey; [Cangur, Sengul] Duzce Univ, Fac Med, Dept Biostat & Med Informat, Duzce, Turkeyen_US
dc.description.abstractBackground: It is important to check the skin of neonates on a daily basis so that abnormal conditions and skin problems are identified. Objectives: This study aimed at testing the validity and reliability of a revised Northampton Neonatal skin assessment tool in Turkish; a review to determine whether it is valid and reliable in the care of neonates. Methods: The research had a cross-sectional and methodological design. The data for the study was collected between 1st of January 2015, and 20th of June 2015, at the neonatal intensive care unit (NICU) of a major training and research hospital in Istanbul/Turkey; 362 neonatal skin assessments were executed. The revised tool's language, face, content, construct validity, and reliability were evaluated. Results: The intra-class correlation coefficient, which indicates interrater reliability, was 1.00 in the study, representing 100% agreement. The Cronbach alpha internal consistency coefficient revealed that the tool's general reliability was at an acceptable level (C alpha = 0.71). Although the model was not found to be significant (Chi-square = 46.22, df = 17, and P < 0.001), the other model fit indices found RMSEA < 0.07, chi(2)/df < 3, and SRMR< 0.06, which meant that the data had an acceptable fit for the model. The model exhibited a good fit because the CFI, NFI, GFI, and AGFI indices were close to 1. When the model fit indices were evaluated in combination, the CFA model generally had a good fit. The most significant and most prominent effect on the tool was the impact of NNS9 (level of care) indicator (b(9) = 0.86, t value = 17.46 > 1.96). Conclusions: The Turkish version of the revised northampton neonatal skin assessment tool is an appropriate, valid, and reliable instrument to be used in the assessment of neonatal skin, especially of infants at the NICU. The tool may be recommended for use in the care of neonates.en_US
dc.identifier.citation1
dc.identifier.doi10.5812/ircmj.64439
dc.identifier.issn2074-1804
dc.identifier.issn2074-1812
dc.identifier.issue12en_US
dc.identifier.scopus2-s2.0-85044960766
dc.identifier.urihttps://doi.org/10.5812/ircmj.64439
dc.identifier.urihttps://hdl.handle.net/20.500.14517/489
dc.identifier.volume19en_US
dc.identifier.wosWOS:000428933600010
dc.identifier.wosqualityQ4
dc.language.isoen
dc.publisherKowsar Publen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectValidityen_US
dc.subjectReliabilityen_US
dc.subjectNeonatalen_US
dc.subjectSkin Toolen_US
dc.titleValidity and Reliability of a Revised Northampton Neonatal Skin Assessment Tool in Turkish Languageen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files