Accuracy of the Anatomic Placement in Ultrasonography Guided Facet Joint Blockage with Supervising of C-Arm Fluoroscopy

dc.authorid erdogan, sinan/0000-0002-8517-3925
dc.authorscopusid 55954339600
dc.authorscopusid 55391232500
dc.authorscopusid 55750987000
dc.authorscopusid 51563604200
dc.authorscopusid 57202358498
dc.authorscopusid 55370867500
dc.authorwosid erdogan, sinan/GZA-9556-2022
dc.contributor.author Erdogan, Sinan
dc.contributor.author Okur, Sibel Caglar
dc.contributor.author Atici, Aysegul
dc.contributor.author Gokcen, Huseyin Bahadir
dc.contributor.author Polat, Baris
dc.contributor.author Atici, Yunus
dc.date.accessioned 2024-05-25T11:41:18Z
dc.date.available 2024-05-25T11:41:18Z
dc.date.issued 2019
dc.department Okan University en_US
dc.department-temp [Erdogan, Sinan; Gokcen, Huseyin Bahadir] Istinye Univ, Dept Orthoped & Traumatol, Med Fac, Istanbul, Turkey; [Okur, Sibel Caglar] Bakirkoy Dr Sadi Konuk Res & Training Hosp, Dept Phys Therapy & Rehabil, Istanbul, Turkey; [Atici, Aysegul] Kartal Training & Res Hosp, Dept Phys Therapy & Rehabil, Istanbul, Turkey; [Polat, Baris] Kyrenia Univ, Dept Orthoped & Traumatol, Med Fac, Sehit Yahya Bakir St, Kyrenia, Cyprus; [Atici, Yunus] Okan Univ, Dept Orthoped & Traumatol, Med Fac, Istanbul, Turkey en_US
dc.description erdogan, sinan/0000-0002-8517-3925 en_US
dc.description.abstract Background: Facet joint blockage is a type of regional anesthesia which is performed selectively on the medial branch of the ramus dorsalis of the spinal nerve and is a current approach for the treatment of pain originating from facet arthropathy. This current approach to chronic low back pain caused by facet joint pathology is usually performed with ultrasound guidance. Objectives: The accuracy of anatomical placement of the facet joint with ultrasonography guidance is determined by C-arm fluoroscopy image taken as reference. Patients and Methods: A total of 22 patients who were diagnosed with facet joint syndrome were involved in the study. After detecting the superolateral corner of the facet joint, which is the target point with ultrasound, the control was provided with C-arm fluoroscopy by giving radiopaque fluid. In order to verify the localization, a mixture of 40 mg triamcinolone and 1 cc 2% lidocaine was injected. Results: Nerve blockage was applied to 67 facet joints at L3 - L4, L4 - L5 and L5 - Si level in a total of 22 patients (15 female and seven male) diagnosed with facet joint syndrome. The patients' mean age was 63 (range, 48 - 80), the mean body mass index was 28.4 (range,18.9 -38.1) and the mean time to determine facet localization with ultrasonography (USG) was 240 seconds (range,140 -320). Patients' mean visual analog scale (VAS) decreased from 7 (range, 6 - 9) to 2.5 (range, 1- 6). In the C-arm fluoroscopy control after the injection of radio-opaque material, the needle was found to be located in the lamina in four segments and it was relocated. In addition to this, two facet joints were not localized in ultrasound. This study concluded that the location of the facet joint with USG guidance is possible with 91% sensitivity and 100% positive predictive value when C-arm fluoroscopy was regarded as a gold standard in determining facet joint localization. No complications were observed. Conclusion: The results showed that ultrasonography guided facet joint block can be considered as a minimally invasive procedure that could be easily applied without radiation exposure. en_US
dc.identifier.citationcount 2
dc.identifier.doi 10.5812/iranjradiol.84389
dc.identifier.issn 1735-1065
dc.identifier.issn 2008-2711
dc.identifier.issue 3 en_US
dc.identifier.scopus 2-s2.0-85068690725
dc.identifier.scopusquality Q4
dc.identifier.uri https://doi.org/10.5812/iranjradiol.84389
dc.identifier.uri https://hdl.handle.net/20.500.14517/1510
dc.identifier.volume 16 en_US
dc.identifier.wos WOS:000478759500003
dc.identifier.wosquality Q4
dc.language.iso en
dc.publisher Briefland en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.scopus.citedbyCount 3
dc.subject Facet Joint Blockage en_US
dc.subject Ultrasonography en_US
dc.subject Fluoroscopy en_US
dc.subject Low Back Pain en_US
dc.title Accuracy of the Anatomic Placement in Ultrasonography Guided Facet Joint Blockage with Supervising of C-Arm Fluoroscopy en_US
dc.type Article en_US
dc.wos.citedbyCount 3
dspace.entity.type Publication

Files