The Influence of Momentary Retention Forces on Patient Satisfaction and Quality of Life of Two-Implant-Retained Mandibular Overdenture Wearers
dc.authorid | GECKILI, ONUR/0000-0002-7852-3915 | |
dc.authorid | Bilmenoglu, Caglar/0000-0002-2580-9899 | |
dc.authorid | Bilhan, Hakan/0000-0003-1787-3003 | |
dc.authorid | Cilingir, Altug/0000-0002-0694-5772 | |
dc.authorscopusid | 15135391400 | |
dc.authorscopusid | 14012620400 | |
dc.authorscopusid | 57197293393 | |
dc.authorscopusid | 56564008900 | |
dc.authorscopusid | 54880603900 | |
dc.authorscopusid | 56563983600 | |
dc.authorscopusid | 56563983600 | |
dc.authorwosid | GECKILI, ONUR/AAD-4973-2020 | |
dc.authorwosid | ozdiler, arda/U-1599-2018 | |
dc.authorwosid | Roose, Emma/ABE-2864-2021 | |
dc.authorwosid | Bilmenoglu, Caglar/HGE-5706-2022 | |
dc.authorwosid | Cilingir, Altug/N-2262-2018 | |
dc.contributor.author | Geckili, Onur | |
dc.contributor.author | Cilingir, Altug | |
dc.contributor.author | Erdogan, Ozge | |
dc.contributor.author | Kesoglu, Aysun Coskun | |
dc.contributor.author | Bilmenoglu, Caglar | |
dc.contributor.author | Ozdiler, Arda | |
dc.contributor.author | Bilhan, Hakan | |
dc.date.accessioned | 2024-05-25T11:18:05Z | |
dc.date.available | 2024-05-25T11:18:05Z | |
dc.date.issued | 2015 | |
dc.department | Okan University | en_US |
dc.department-temp | [Geckili, Onur; Cilingir, Altug; Erdogan, Ozge; Kesoglu, Aysun Coskun; Bilmenoglu, Caglar; Ozdiler, Arda] Istanbul Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey; [Bilhan, Hakan] Okan Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey | en_US |
dc.description | GECKILI, ONUR/0000-0002-7852-3915; Bilmenoglu, Caglar/0000-0002-2580-9899; Bilhan, Hakan/0000-0003-1787-3003; Cilingir, Altug/0000-0002-0694-5772 | en_US |
dc.description.abstract | Purpose: The purpose of this study was to assess the influence of momentary retention forces on patient satisfaction and quality of life of two-implant-retained mandibular overdenture wearers. Materials and Methods: Edentulous patients who had been rehabilitated with two-implant-supported mandibular overdentures with single attachments and maxillary complete dentures at a university clinic were included in this study. The overdenture attachments were either ball or locator attachments. All the patients completed the Turkish version of the Oral Health Impact Profile-14 (OHIP-14) and the visual analog scale (VAS) satisfaction questionnaires. Momentary retention forces of the overdentures were measured using a custom-made dynamic testing machine. Results: Fifty-five patients were included in this study. No statistically significant association was detected between momentary retention forces and VAS scores (P > .05), but higher retention forces presented significantly better quality of life scores in the social disability and handicap domains of OHIP14 (P < .05). Conclusion: Within the limitations of this clinical study, it may be presumed that although higher instant retention force of an implant-retained overdenture provides better quality of life, it does not affect patient satisfaction. | en_US |
dc.identifier.citation | 15 | |
dc.identifier.doi | 10.11607/jomi.3774 | |
dc.identifier.endpage | 402 | en_US |
dc.identifier.issn | 0882-2786 | |
dc.identifier.issn | 1942-4434 | |
dc.identifier.issue | 2 | en_US |
dc.identifier.pmid | 25506644 | |
dc.identifier.scopus | 2-s2.0-84953344399 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 397 | en_US |
dc.identifier.uri | https://doi.org/10.11607/jomi.3774 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14517/292 | |
dc.identifier.volume | 30 | en_US |
dc.identifier.wos | WOS:000367243200021 | |
dc.identifier.wosquality | Q3 | |
dc.language.iso | en | |
dc.publisher | Quintessence Publishing Co inc | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | interforaminal implants | en_US |
dc.subject | mandibular overdenture | en_US |
dc.subject | momentary retention forces | en_US |
dc.subject | patient satisfaction | en_US |
dc.subject | quality of life | en_US |
dc.title | The Influence of Momentary Retention Forces on Patient Satisfaction and Quality of Life of Two-Implant-Retained Mandibular Overdenture Wearers | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |