The Influence of Momentary Retention Forces on Patient Satisfaction and Quality of Life of Two-Implant-Retained Mandibular Overdenture Wearers

dc.authoridGECKILI, ONUR/0000-0002-7852-3915
dc.authoridBilmenoglu, Caglar/0000-0002-2580-9899
dc.authoridBilhan, Hakan/0000-0003-1787-3003
dc.authoridCilingir, Altug/0000-0002-0694-5772
dc.authorscopusid15135391400
dc.authorscopusid14012620400
dc.authorscopusid57197293393
dc.authorscopusid56564008900
dc.authorscopusid54880603900
dc.authorscopusid56563983600
dc.authorscopusid56563983600
dc.authorwosidGECKILI, ONUR/AAD-4973-2020
dc.authorwosidozdiler, arda/U-1599-2018
dc.authorwosidRoose, Emma/ABE-2864-2021
dc.authorwosidBilmenoglu, Caglar/HGE-5706-2022
dc.authorwosidCilingir, Altug/N-2262-2018
dc.contributor.authorGeckili, Onur
dc.contributor.authorCilingir, Altug
dc.contributor.authorErdogan, Ozge
dc.contributor.authorKesoglu, Aysun Coskun
dc.contributor.authorBilmenoglu, Caglar
dc.contributor.authorOzdiler, Arda
dc.contributor.authorBilhan, Hakan
dc.date.accessioned2024-05-25T11:18:05Z
dc.date.available2024-05-25T11:18:05Z
dc.date.issued2015
dc.departmentOkan Universityen_US
dc.department-temp[Geckili, Onur; Cilingir, Altug; Erdogan, Ozge; Kesoglu, Aysun Coskun; Bilmenoglu, Caglar; Ozdiler, Arda] Istanbul Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey; [Bilhan, Hakan] Okan Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkeyen_US
dc.descriptionGECKILI, ONUR/0000-0002-7852-3915; Bilmenoglu, Caglar/0000-0002-2580-9899; Bilhan, Hakan/0000-0003-1787-3003; Cilingir, Altug/0000-0002-0694-5772en_US
dc.description.abstractPurpose: The purpose of this study was to assess the influence of momentary retention forces on patient satisfaction and quality of life of two-implant-retained mandibular overdenture wearers. Materials and Methods: Edentulous patients who had been rehabilitated with two-implant-supported mandibular overdentures with single attachments and maxillary complete dentures at a university clinic were included in this study. The overdenture attachments were either ball or locator attachments. All the patients completed the Turkish version of the Oral Health Impact Profile-14 (OHIP-14) and the visual analog scale (VAS) satisfaction questionnaires. Momentary retention forces of the overdentures were measured using a custom-made dynamic testing machine. Results: Fifty-five patients were included in this study. No statistically significant association was detected between momentary retention forces and VAS scores (P > .05), but higher retention forces presented significantly better quality of life scores in the social disability and handicap domains of OHIP14 (P < .05). Conclusion: Within the limitations of this clinical study, it may be presumed that although higher instant retention force of an implant-retained overdenture provides better quality of life, it does not affect patient satisfaction.en_US
dc.identifier.citation15
dc.identifier.doi10.11607/jomi.3774
dc.identifier.endpage402en_US
dc.identifier.issn0882-2786
dc.identifier.issn1942-4434
dc.identifier.issue2en_US
dc.identifier.pmid25506644
dc.identifier.scopus2-s2.0-84953344399
dc.identifier.scopusqualityQ2
dc.identifier.startpage397en_US
dc.identifier.urihttps://doi.org/10.11607/jomi.3774
dc.identifier.urihttps://hdl.handle.net/20.500.14517/292
dc.identifier.volume30en_US
dc.identifier.wosWOS:000367243200021
dc.identifier.wosqualityQ3
dc.language.isoen
dc.publisherQuintessence Publishing Co incen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectinterforaminal implantsen_US
dc.subjectmandibular overdentureen_US
dc.subjectmomentary retention forcesen_US
dc.subjectpatient satisfactionen_US
dc.subjectquality of lifeen_US
dc.titleThe Influence of Momentary Retention Forces on Patient Satisfaction and Quality of Life of Two-Implant-Retained Mandibular Overdenture Wearersen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files