Effects of inter-implant distance and implant length on the response to frontal traumatic force of two anterior implants in an atrophic mandible: Three-dimensional finite element analysis

dc.authorscopusid36183962200
dc.authorscopusid55334954900
dc.authorscopusid57197628935
dc.authorscopusid55832456300
dc.authorscopusid56568277100
dc.contributor.authorKan,B.
dc.contributor.authorCoskunses,F.M.
dc.contributor.authorMutlu,I.
dc.contributor.authorUgur,L.
dc.contributor.authorMeral,D.G.
dc.contributor.otherAğız,Diş ve Çene Cerrahisi / Oral, Dental and Maxillofacial Surgery
dc.date.accessioned2024-05-25T12:32:02Z
dc.date.available2024-05-25T12:32:02Z
dc.date.issued2015
dc.departmentOkan Universityen_US
dc.department-tempKan B., Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Kocaeli University, Basiskele-Kocaeli, PC 41190, Turkey; Coskunses F.M., Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Kocaeli University, Basiskele-Kocaeli, PC 41190, Turkey; Mutlu I., Department of Biomechanics, Faculty of Technology, Biomedical Engineering, Kocaeli University, Kocaeli, Turkey; Ugur L., Automotive Department, Technical Science Vocational School, Amasya University, Amasya, Turkey; Meral D.G., Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Okan University, Istanbul, Turkeyen_US
dc.description.abstractThe aim of this three-dimensional finite element analysis study was to examine the biomechanical behaviour of dental implants and the surrounding bone under traumatic frontal force. Models were created of an edentulous atrophic mandible using cone beam computed tomography data from a patient; two titanium alloy implants (Ti-6Al-4V) were virtually inserted into the anterior of the mandible. Six different variations were modelled to represent differences in implant location (lateral incisor vs. canine placement) and implant length (monocortical, bicortical, and long-bicortical). A static force of 10 MPa was applied frontally to the symphysis region of each model, and the maximum equivalent von Mises strain of bone, maximum von Mises stress of implants, and chromatic force distributions in bone and implants were recorded. In general, when compared to lateral incisor placement, canine placement of implants resulted in greater von Mises stress on implants and greater equivalent von Mises strain on bone. The findings of the present study showed the distribution of traumatic force to be affected more by inter-implant distance than by implant length. The insertion of implants in the lateral incisor area was found to be a better solution than canine area placement in terms of frontal plane trauma and fracture risk. © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.en_US
dc.identifier.citation15
dc.identifier.doi10.1016/j.ijom.2015.03.002
dc.identifier.endpage913en_US
dc.identifier.issn0901-5027
dc.identifier.issue7en_US
dc.identifier.pmidPubMed:25818310
dc.identifier.scopus2-s2.0-84937523251
dc.identifier.scopusqualityQ1
dc.identifier.startpage908en_US
dc.identifier.urihttps://doi.org/10.1016/j.ijom.2015.03.002
dc.identifier.urihttps://hdl.handle.net/20.500.14517/2329
dc.identifier.volume44en_US
dc.identifier.wosqualityQ2
dc.institutionauthorKan B.
dc.institutionauthorKan, Bahadır
dc.language.isoen
dc.publisherChurchill Livingstoneen_US
dc.relation.ispartofInternational Journal of Oral and Maxillofacial Surgeryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectdental implanten_US
dc.subjectfractureen_US
dc.subjectmandibleen_US
dc.subjectvon Misesen_US
dc.titleEffects of inter-implant distance and implant length on the response to frontal traumatic force of two anterior implants in an atrophic mandible: Three-dimensional finite element analysisen_US
dc.typeArticleen_US
dspace.entity.typePublication
relation.isAuthorOfPublication37ea87f9-c176-4abc-9e40-da0c77f77ac6
relation.isAuthorOfPublication.latestForDiscovery37ea87f9-c176-4abc-9e40-da0c77f77ac6
relation.isOrgUnitOfPublication9d7f58b2-6caf-4591-83fc-e79c39a149f4
relation.isOrgUnitOfPublication.latestForDiscovery9d7f58b2-6caf-4591-83fc-e79c39a149f4

Files