3D FEA of Hollow and Solid Design Zirconia Dental Dowels

No Thumbnail Available

Date

2016

Journal Title

Journal ISSN

Volume Title

Publisher

Wiley

Open Access Color

OpenAIRE Downloads

OpenAIRE Views

Research Projects

Organizational Units

Journal Issue

Abstract

PurposeThe aim of this study was to evaluate the stress distribution of hollow and solid design zirconia dowels. Materials and MethodsFinite element analysis (FEA) was used to investigate the influence of different dowel designs on the stress distribution of zirconia dowels. The coronal diameter of the dowel was 2.2 mm, the apical diameter was 1.8 mm, and the length was 15 mm. The diameter of the hollow space was 1.2 mm. Occlusal forces (both parallel and oblique) of 100 N were applied from the wider edge of the dowels simulating loads acting on the incisor during clenching and incising. The results were expressed in terms of von Mises criteria. ResultsFEA revealed differences in stress distribution. During parallel load, the maximum tensile stress of the hollow design (89.40 MPa) was greater than the solid design (43.30 MPa). During oblique load, the maximum tensile stress of the hollow design (1437.90 MPa) was greater than the solid design (917.96 MPa). The maximum deformation was observed in the coronal part of the dowel in both designs under the two load directions. ConclusionsFEA results showed that the hollow design zirconia dowels presented higher tensile stress.

Description

YAY, Kubilay/0000-0003-3510-0864; Kazazoglu, Ender/0000-0002-6450-9709

Keywords

Zirconia, hollow design, finite element analysis

Turkish CoHE Thesis Center URL

Fields of Science

Citation

1

WoS Q

Q1

Scopus Q

Q1

Source

Volume

25

Issue

3

Start Page

229

End Page

234