Measurement of radiation dose in thyroid scintigraphy

No Thumbnail Available

Date

2020

Journal Title

Journal ISSN

Volume Title

Publisher

Polish Academy of Sciences

Open Access Color

OpenAIRE Downloads

OpenAIRE Views

Research Projects

Organizational Units

Journal Issue

Abstract

Determination of radiation dose rate is very important for public health and medical workers because the nuclear radiation is hazardous for all. In this study, radiation dose rate was determined after radiopharmaceutical injection for thyroid scintigraphy. Measurements of the dose rate were made at 12 different points: 25, 50, 100, and 200 cm from the patient’s head, chest and foot level. Moreover, measurements were made at different times with GM counter to determine the dose rate decay. The amount of radioactivity injected into patients varies between 151 MBq (4.1 Ci) and 192 MBq (5.2 Ci), with average value of 162 MBq (4.4 Ci). The radiation dose rate at 100 cm from the patient’s chest level, after 9.16, 28.83 and 49.66 min of injection was calculated as 7.56, 6.35 and 4.73 µSvh−1, respectively. After Tc-99m injection, healthcare professionals must be 1 m away from the patient for radiation safety. It was also emphasized that the public should not be in proximity to the patient nearer than 1 m for 3 h after injection. © 2020 Polish Academy of Sciences. All rights reserved.

Description

Keywords

[No Keyword Available]

Turkish CoHE Thesis Center URL

Fields of Science

Citation

34

WoS Q

Q4

Scopus Q

Q3

Source

Acta Physica Polonica A

Volume

137

Issue

4

Start Page

569

End Page

573