Measurement of radiation dose in thyroid scintigraphy
No Thumbnail Available
Date
2020
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Polish Academy of Sciences
Open Access Color
OpenAIRE Downloads
OpenAIRE Views
Abstract
Determination of radiation dose rate is very important for public health and medical workers because the nuclear radiation is hazardous for all. In this study, radiation dose rate was determined after radiopharmaceutical injection for thyroid scintigraphy. Measurements of the dose rate were made at 12 different points: 25, 50, 100, and 200 cm from the patient’s head, chest and foot level. Moreover, measurements were made at different times with GM counter to determine the dose rate decay. The amount of radioactivity injected into patients varies between 151 MBq (4.1 Ci) and 192 MBq (5.2 Ci), with average value of 162 MBq (4.4 Ci). The radiation dose rate at 100 cm from the patient’s chest level, after 9.16, 28.83 and 49.66 min of injection was calculated as 7.56, 6.35 and 4.73 µSvh−1, respectively. After Tc-99m injection, healthcare professionals must be 1 m away from the patient for radiation safety. It was also emphasized that the public should not be in proximity to the patient nearer than 1 m for 3 h after injection. © 2020 Polish Academy of Sciences. All rights reserved.
Description
Keywords
[No Keyword Available]
Turkish CoHE Thesis Center URL
Fields of Science
Citation
34
WoS Q
Q4
Scopus Q
Q3
Source
Acta Physica Polonica A
Volume
137
Issue
4
Start Page
569
End Page
573