Influence of the Localization of Frontal Bone Defects on Primary Stability Values of 2 Different Implant Designs: An <i>In Vitro</i> Study

dc.authorid AYKOL SAHIN, GÖKÇE/0000-0001-7644-6349
dc.authorid GECKILI, ONUR/0000-0002-7852-3915
dc.authorid KAZOKOGLU, SEHNAZ/0000-0001-5632-5814
dc.authorid Bilhan, Hakan/0000-0003-1787-3003
dc.authorscopusid 55903369400
dc.authorscopusid 35267920900
dc.authorscopusid 56568277100
dc.authorscopusid 57192948734
dc.authorscopusid 57192948509
dc.authorscopusid 15135391400
dc.authorwosid mercan, ugur/AAQ-4352-2020
dc.authorwosid AYKOL SAHIN, GÖKÇE/GXH-8379-2022
dc.authorwosid KAZOKOĞLU, ŞEHNAZ/X-9518-2019
dc.authorwosid GECKILI, ONUR/AAD-4973-2020
dc.contributor.author Mercan, Ugur
dc.contributor.author Bilhan, Hakan
dc.contributor.author Meral, Deniz Gokce
dc.contributor.author Kazokoglu, Sehnaz
dc.contributor.author Aykol-Sahin, Gokce
dc.contributor.author Geckili, Onur
dc.date.accessioned 2024-05-25T11:19:51Z
dc.date.available 2024-05-25T11:19:51Z
dc.date.issued 2017
dc.department Okan University en_US
dc.department-temp [Mercan, Ugur; Meral, Deniz Gokce] Okan Univ, Sch Dent, Dept Oral & Maxillofacial Surg, Oya Sok 23-A, TR-34394 Istanbul, Turkey; [Bilhan, Hakan; Kazokoglu, Sehnaz] Okan Univ, Sch Dent, Dept Prosthodont, Istanbul, Turkey; [Aykol-Sahin, Gokce] Okan Univ, Sch Dent, Dept Periodontol, Istanbul, Turkey; [Geckili, Onur] Istanbul Univ, Sch Dent, Dept Prosthodont, Istanbul, Turkey en_US
dc.description AYKOL SAHIN, GÖKÇE/0000-0001-7644-6349; GECKILI, ONUR/0000-0002-7852-3915; KAZOKOGLU, SEHNAZ/0000-0001-5632-5814; Bilhan, Hakan/0000-0003-1787-3003 en_US
dc.description.abstract Objectives: The aim of this study was to determine the influence of different frontal bone defect localizations on primary stability values of 2 different implant designs. Materials and Methods: Eight cow rib segments were prepared before implant installation, as 2 segments with coronal, 2 with middle, and 2 with apical defects and 2 with control. Thirty-two cylindrical and 32 tapered implants were placed in the remaining 4 segments. Implant stability measurements were performed using electronic percussive testing and resonance frequency analysis. Results: No significance was detected between the stability values of the 2 implant designs except the implant stability quotient (ISQ) of control groups. The tapered implants control group showed significantly higher lateral ISQs compared with cylindrical implants (P = 0.033). For both implant types, stability values were significantly lower in coronal defects (P < 0.01). No significant differences were detected in other defect types. Conclusion: Within the limitations of this study, it may be concluded that coronal defects may influence primary stability negatively, compared with middle and apical defects. Although statistically not significant, coronal defects caused lower primary stability values with the tapered design compared with parallel design. en_US
dc.description.sponsorship Okan University, Dentistry School, Istanbul, Turkey en_US
dc.description.sponsorship The authors declare that there is no conflict of interest associated with this study. The study was supported by Okan University, Dentistry School, Istanbul, Turkey. en_US
dc.identifier.citationcount 5
dc.identifier.doi 10.1097/ID.0000000000000536
dc.identifier.endpage 94 en_US
dc.identifier.issn 1056-6163
dc.identifier.issue 1 en_US
dc.identifier.pmid 28079610
dc.identifier.scopus 2-s2.0-85009394757
dc.identifier.startpage 87 en_US
dc.identifier.uri https://doi.org/10.1097/ID.0000000000000536
dc.identifier.uri https://hdl.handle.net/20.500.14517/453
dc.identifier.volume 26 en_US
dc.identifier.wos WOS:000393668300012
dc.institutionauthor Meral, Deniz Gökçe
dc.institutionauthor Aykol Şahin, Gökçe
dc.language.iso en
dc.publisher Lippincott Williams & Wilkins en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 4
dc.subject dental implant en_US
dc.subject electronic percussive testing en_US
dc.subject resonance frequency analysis en_US
dc.subject defect localization en_US
dc.title Influence of the Localization of Frontal Bone Defects on Primary Stability Values of 2 Different Implant Designs: An <i>In Vitro</i> Study en_US
dc.type Article en_US
dc.wos.citedbyCount 5

Files