Comparison of the Primary Stability of Two Implant Designs in Two Different Bone Types: An In Vitro Study

dc.authorid GECKILI, ONUR/0000-0002-7852-3915
dc.authorid Bilmenoglu, Caglar/0000-0002-2580-9899
dc.authorid Bilhan, Hakan/0000-0003-1787-3003
dc.authorid Cilingir, Altug/0000-0002-0694-5772
dc.authorscopusid 35267920900
dc.authorscopusid 54880603900
dc.authorscopusid 56436890900
dc.authorscopusid 55839290100
dc.authorscopusid 16548947000
dc.authorscopusid 14012620400
dc.authorscopusid 14012620400
dc.authorwosid GECKILI, ONUR/AAD-4973-2020
dc.authorwosid Ates, Gokcen/AAR-9995-2021
dc.authorwosid BURAL, HAYRUNNİSA CANAN/AAE-1151-2020
dc.authorwosid Bilmenoglu, Caglar/HGE-5706-2022
dc.authorwosid Cilingir, Altug/N-2262-2018
dc.contributor.author Bilhan, Hakan
dc.contributor.author Bilmenoglu, Caglar
dc.contributor.author Urgun, Aliye Ceren
dc.contributor.author Ates, Gokcen
dc.contributor.author Bural, Canan
dc.contributor.author Cilingir, Altug
dc.contributor.author Geckili, Onur
dc.date.accessioned 2024-05-25T11:18:06Z
dc.date.available 2024-05-25T11:18:06Z
dc.date.issued 2015
dc.department Okan University en_US
dc.department-temp [Bilhan, Hakan] Okan Univ, Dept Prosthodont, Fac Dent, Istanbul, Turkey; [Bilmenoglu, Caglar] Trakya Univ, Dept Prosthodont, Fac Dent, Edirne, Turkey; [Urgun, Aliye Ceren; Ates, Gokcen; Bural, Canan; Geckili, Onur] Istanbul Univ, Dept Prosthodont, Fac Dent, TR-34093 Istanbul, Turkey; [Cilingir, Altug] Trakya Univ, Dept Prosthodont, Fac Dent, Edirne, Turkey en_US
dc.description GECKILI, ONUR/0000-0002-7852-3915; Bilmenoglu, Caglar/0000-0002-2580-9899; Bilhan, Hakan/0000-0003-1787-3003; Cilingir, Altug/0000-0002-0694-5772 en_US
dc.description.abstract Purpose: Achievement of primary stability upon surgical placement of dental implants is a key factor for successful osseointegration and depends mainly on implant-related factors. The aim of this study was to compare and assess the primary stability of implants with active and regular threads in type 2 as well as type 4 bone. Materials and Methods: Fresh cow vertebrae and a pelvis were used as models of type 4 bone and type 2 bone, respectively. Implants with two different designs-regular-threaded and active-threaded-both 4.3 mm wide and 13 mm long, were placed in both types of bone (n = 80). Stability measurements were completed by four prosthodontists using two different Periotest devices and resonance frequency analysis. Statistical analyses were performed with the Mann-Whitney U test. Results: No statistically significant differences were found between the implant types in either type of bone in the stability measured with different methods. For both implant types, the mean resonance frequency values in type 2 bone were statistically significantly higher than in type 4 bone, whereas the mean Periotest values in type 2 bone were statistically significantly lower than in type 4 bone. Conclusion: Within the limitations of this in vitro study in bone types 2 and 4, the active-threaded implant, which was invented to increase primary stability, did not show higher primary stability compared to a regular-threaded implant. en_US
dc.description.sponsorship Research Fund of Istanbul University [30813] en_US
dc.description.sponsorship This study was financially supported and approved by the Research Fund of Istanbul University (project no. 30813). The authors reported no conflicts of interest related to this study. en_US
dc.identifier.citationcount 13
dc.identifier.doi 10.11607/jomi.3939
dc.identifier.endpage 1040 en_US
dc.identifier.issn 0882-2786
dc.identifier.issn 1942-4434
dc.identifier.issue 5 en_US
dc.identifier.pmid 26394338
dc.identifier.scopus 2-s2.0-84983517120
dc.identifier.scopusquality Q2
dc.identifier.startpage 1036 en_US
dc.identifier.uri https://doi.org/10.11607/jomi.3939
dc.identifier.uri https://hdl.handle.net/20.500.14517/296
dc.identifier.volume 30 en_US
dc.identifier.wos WOS:000367251300006
dc.identifier.wosquality Q3
dc.language.iso en
dc.publisher Quintessence Publishing Co inc en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 11
dc.subject bone quality en_US
dc.subject bone-implant interface en_US
dc.subject immediate loading en_US
dc.subject implant design en_US
dc.subject implant stability en_US
dc.title Comparison of the Primary Stability of Two Implant Designs in Two Different Bone Types: An In Vitro Study en_US
dc.type Article en_US
dc.wos.citedbyCount 11

Files