Comparison of the use of piezosurgery expander and conventional instruments on primary implant stability

dc.authorid Erdogan, Ozgur/0000-0003-1547-2513
dc.authorscopusid 55903369400
dc.authorscopusid 36916526700
dc.authorwosid mercan, ümit/AAM-7482-2021
dc.contributor.author Mercan, U.
dc.contributor.author Erdogan, O.
dc.date.accessioned 2024-05-25T12:30:14Z
dc.date.available 2024-05-25T12:30:14Z
dc.date.issued 2020
dc.department Okan University en_US
dc.department-temp [Mercan, U.; Erdogan, O.] Okan Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Gulbahar Mh Oya Sok 23-A, TR-34394 Istanbul, Turkey en_US
dc.description Erdogan, Ozgur/0000-0003-1547-2513 en_US
dc.description.abstract Objective: To compare the use of a piezosurgery expander and conventional chisel/osteotome on primary implant stability. Materials and Methods: Twenty fresh ribs were divided into two main groups; group P and group C. In group P, bone expansion was performed using piezosurgery. In group C, bone expansion was performed using conventional chisel osteotomy. In both groups, the implants were inserted into the ribs after bone expansion. After implant placement, primary stability values were evaluated from the bucco-lingual (B-L) and mesio-distal (M-D) sides of the implant. Results: The primary stability values on the B-L side of both implants in group P were significantly higher than in group C (P < 0.05). Conclusion: The use of piezo-expanders in the alveolar split technique has better effects on primary implant stability compared with the conventional technique. en_US
dc.identifier.citationcount 1
dc.identifier.doi 10.4103/njcp.njcp_132_20
dc.identifier.endpage 1522 en_US
dc.identifier.issn 1119-3077
dc.identifier.issue 11 en_US
dc.identifier.pmid 33221775
dc.identifier.scopus 2-s2.0-85096631666
dc.identifier.scopusquality Q2
dc.identifier.startpage 1517 en_US
dc.identifier.uri https://doi.org/10.4103/njcp.njcp_132_20
dc.identifier.uri https://hdl.handle.net/20.500.14517/2188
dc.identifier.volume 23 en_US
dc.identifier.wos WOS:000617096500006
dc.identifier.wosquality Q4
dc.language.iso en
dc.publisher Wolters Kluwer Medknow Publications en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 2
dc.subject Alveolar ridge split en_US
dc.subject implant en_US
dc.subject piezosurgery expander en_US
dc.subject primary stability en_US
dc.title Comparison of the use of piezosurgery expander and conventional instruments on primary implant stability en_US
dc.type Article en_US
dc.wos.citedbyCount 2

Files