Browsing by Author "Isildak, Ibrahim"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Article Citation Count: 3Fe3+ - Ion Selective Electrode Developed as a Detector in Flow Injection Analysis(Bentham Science Publ Ltd, 2015) Demir, Ersin; Kemer, Baris; Isildak, Ibrahim; Aboul-Enein, Hassan Y.A new polyvinyl chloride (PVC) membrane Fe3+ - ion selective electrode was constructed as a detector for the analysis Fe3+ using a home-made low-volume flow through cell. Optimum working conditions for the flow injection analysis (FIA) measurements were examined. In addition, under optimum conditions, potentiometric performance characteristics of the Fe3+ ion-selective electrode were investigated. Electrode had a linear response in the concentration range of 1.0 x 10(-3)-1.0 x 10(-6) M (R-2=0.9961, y=24.7+772.0). Reproducibility of the electrode responses was very satisfied. The potential of Fe3+ ion selective electrode was decreased intra and inter day 0.9 % and 3.7% respectively. The designed flow-through cell system as Fe3+ detector revealed sampling rates of approximately 50 injections per hour. The obtained results in FIA were in a good agreement with AAs results at % 95 confidence level for each syrups.Article Citation Count: 15A Novel all Solid-State Contact PVC-Membrane Beryllium-Selective Electrode Based on 4-Hydroxybenzo-15-Crown-5 Ether Ionophore(Bentham Science Publ Ltd, 2018) Isildak, Ibrahim; Attar, Azade; Demir, Ersin; Kemer, Baris; Aboul-Enein, Hassan Y.Aim: A novel all solid-state contact PVC-membrane beryllium-selective electrode based on 4-hydroxybenzo-15-crown-5 ether as an ionophore is described. Results: The best performance was obtained with a membrane composition of 4% ionophore, 67% dioctyl sebacate (DOS), 28% poly(vinyl chloride) (PVC), and 1% potassium tetrakis (p-chloro) phenylborate (KTClPB) (w/w). The all solid-state contact PVCmembrane beryllium-selective electrode together with an Ag/AgCl reference electrode exhibited sub-Nernstian response with a slope of 22 +/- 1 mV/decade to beryllium ions from 1.0x10(-6) to 1.0x10(-1) M, and resulted a considerably low detection limit of 6.2x10(-7). The electrode had a good performance in selectivity over a wide range of interfering cations tested. It showed a working pH range between 4.0-8.2 with fast response time (< 10 s) and a good reproducibility. Conclusion: The all solid-state contact PVC-membrane beryllium-selective electrode developed was successfully applied in potentiometric titration of Be2+ ions with EDTA.