PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/20.500.14517/21
Browse
Browsing PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection by Language "en"
Now showing 1 - 20 of 778
- Results Per Page
- Sort Options
Article Citation Count: 0A 3-year-old child with multi-drug resistant epilepsy responding to pharmacological and nonpharmacological treatments(Taylor & Francis Ltd, 2023) Coskun, Yesim; Yildirim, CananIntroduction: Despite the development of new antiseizure drugs (ASDs), around one third of epilepsy patients become refractory to treatment or experience adverse events due to ASDs. Therefore, discovery of new ASDs and new therapy options are crucial to improve the quality of life. Herein, we report a 3-year-old child with multi-drug resistant epilepsy caused by perinatal asphyxia whose seizures were reduced by 90% after the introduction of ketogenic diet, vagal nerve stimulation (VNS) AspireSR (SR-seizure response) and oral cannabidiol.Case presentation: A 9-month-old female infant had a history of multidrug resistant epilepsy due to perinatal asphyxia. At admission, she was experiencing up to 20-25 seizures per day lasting for 2-3 minutes. In addition to antiseizure drugs (ASDs), she was put on ketogenic diet (KD), vagal nerve stimulation (VNS) aspire seizure response (AspireSR) was inserted and oral cannabidiol (CBD) was started sequentially. Using pharmacological and nonph armacological therapies, her seizures have been reduced by 90%.Conclusion: The concurrent use of pharmacological and nonpharmacological therapies may be beneficial to improve seizures in infants with multi- Furthermore, our patient is the youngest child inserted VNS AspireSR in Turkey.Review Citation Count: 03D and 4D printing of MXene-based composites: from fundamentals to emerging applications(Royal Soc Chemistry, 2024) Bigham, Ashkan; Zarepour, Atefeh; Khosravi, Arezoo; Iravani, Siavash; Zarrabi, Ali; Genetik ve Biyomühendislik / Genetic and Bio-EngineeringThe advent of three-dimensional (3D) and four-dimensional (4D) printing technologies has significantly improved the fabrication of advanced materials, with MXene-based composites emerging as a particularly promising class due to their exceptional electrical, mechanical, and chemical properties. This review explores the fundamentals of MXenes and their composites, examining their unique characteristics and the underlying principles of their synthesis and processing. We highlight the transformative potential of 3D and 4D printing techniques in tailoring MXene-based materials for a wide array of applications. In the field of tissue regeneration, MXene composites offer enhanced biocompatibility and mechanical strength, making them ideal for scaffolds and implants. For drug delivery, the high surface area and tunable surface chemistry of MXenes enable precise control over drug release profiles. In energy storage, MXene-based electrodes exhibit superior conductivity and capacity, paving the way for next-generation batteries and supercapacitors. Additionally, the sensitivity and selectivity of MXene composites make them excellent candidates for various (bio)sensing applications, from environmental monitoring to biomedical diagnostics. By integrating the dynamic capabilities of 4D printing, which introduces time-dependent shape transformations, MXene-based composites can further adapt to complex and evolving functional requirements. This review provides a comprehensive overview of the current state of research, identifies key challenges, and discusses future directions for the development and application of 3D and 4D printed MXene-based composites. Through this exploration, we aim to underscore the significant impact of these advanced materials and technologies on diverse scientific and industrial fields. This review highlights the developments in the 3D/4D printing of MXene-based composites, focusing on their application in tissue regeneration, drug delivery, sensing, and energy storage.Article Citation Count: 13D FEA of Hollow and Solid Design Zirconia Dental Dowels(Wiley, 2016) Kayahan, Mehmet Baybora; Ozkurt-Kayahan, Zeynep; Yay, Kubilay; Kazazoglu, EnderPurposeThe aim of this study was to evaluate the stress distribution of hollow and solid design zirconia dowels. Materials and MethodsFinite element analysis (FEA) was used to investigate the influence of different dowel designs on the stress distribution of zirconia dowels. The coronal diameter of the dowel was 2.2 mm, the apical diameter was 1.8 mm, and the length was 15 mm. The diameter of the hollow space was 1.2 mm. Occlusal forces (both parallel and oblique) of 100 N were applied from the wider edge of the dowels simulating loads acting on the incisor during clenching and incising. The results were expressed in terms of von Mises criteria. ResultsFEA revealed differences in stress distribution. During parallel load, the maximum tensile stress of the hollow design (89.40 MPa) was greater than the solid design (43.30 MPa). During oblique load, the maximum tensile stress of the hollow design (1437.90 MPa) was greater than the solid design (917.96 MPa). The maximum deformation was observed in the coronal part of the dowel in both designs under the two load directions. ConclusionsFEA results showed that the hollow design zirconia dowels presented higher tensile stress.Article Citation Count: 3A 3D finite element analysis of stress distribution on different thicknesses of mineral trioxide aggregate applied on various sizes of pulp perforation(Springer Heidelberg, 2020) Ozkurt-Kayahan, Zeynep; Turgut, B.; Akin, H.; Kayahan, M. B.; Kazazoglu, E.; Periodontoloji / PeriodontologyObjectives The aim of this study was to evaluate the stress distribution on different thicknesses of mineral trioxide aggregate (MTA) placed on various widths of pulp perforations during the condensation of the composite resin material. Materials and methods The mandibular molar tooth was modeled by COSMOSWorks program (SolidWorks, Waltham, MA). Three finite elemental analysis models representing 3 different dimensions of pulp perforations, 1, 2, and 3 mm in diameter, were created. The perforation area was assumed as filled with MTA with different thicknesses, 1, 2, and 3 mm for each pulp perforation width, creating a total of 9 different models. Then, a composite resin material was layered on MTA for each model. A 66.7 N load was applied and an engineering simulation program (ANSYS, Canonsburg, US) was used for the analysis. Results were presented considering von Mises stress criteria. Results As MTA thickness increased, the stress values recorded within the area between pulp and MTA decreased. Strain was decreased when the thickness of MTA increased. Conclusions Stresses at MTA-pulp interface and strain on MTA decreased with the increase in MTA thickness.Article Citation Count: 05-Year clinical performance of ceramic onlay and overlay restorations luted with light-cured composite resin(Elsevier Sci Ltd, 2024) Yurdaguven, Gulsah Yenier; Ciftcioglu, Elif; Kazokoglu, Fatma Sehnaz; Kayahan, Mehmet Baybora; Endodonti / EndodonticsObjectives: This prospective clinical trial evaluated the clinical performance of ceramic partial coverage indirect adhesive restorations (PCIARs) in posterior teeth luted with a light-cured composite resin. Methods: From April 2016 to January 2017, a total of 60 patients (27 males, 33 females; mean age: 42.2 +/- 10.86 years old) received 83 glass-ceramic PCIARs (26 onlay, 57 overlay) made of IPS Emax CAD (Ivoclar Vivadent). All restorations were luted with a light-cured composite resin (Filtek Z250, 3 M ESPE) by two operators. Two independent calibrated examiners blinded to the operators performing the treatment evaluated the restorations at baseline, 1-year, and 5-year following FDI World Dental Federation criteria including esthetic, functional, and biological properties. Data were analyzed with the Friedman test and the Wilcoxon sign test (p p < 0.05). Results: None of the restorations failed due to fracture or retention loss. One restoration was clinically unsatisfactory because of secondary caries. Marginal staining (p:0.000), marginal adaptation (p:0.018) showed significant differences between 1-year and 5-year recall. Conclusions: The PCIARs demonstrated excellent clinical performance at 1-year period. The degradation parameters appeared as minor staining and minor irregularities after 5-year, without any affect on the clinical performance.Article Citation Count: 11Accuracy of Digital Impressions Obtained Using Six Intraoral Scanners in Partially Edentulous Dentitions and the Effect of Scanning Sequence(Quintessence Publishing Co inc, 2021) Diker, Burcu; Tak, OnjenPurpose: To compare the accuracy of six intraoral scanners in two different partially edentulous maxillary models and to evaluate the effect of scanning sequence on accuracy. Materials and Methods: Maxillary Kennedy Class I and Class IV situations were used as reference models. The reference datasets were obtained by scanning the models using a highly accurate industrial scanner (ATOS Core 80, GOM). The following six intraoral scanners were evaluated: Trios 3 (3Shape), iTero Element 2 (Align Technology), Emerald (Planmeca), CEREC Omnicam (Dentsply Sirona), CEREC Primescan (Dentsply Sirona), and Virtuo Vivo (Dental Wings). A total of 120 scans from both models were obtained using the six intraoral scanners and divided into two groups based on scanning sequence. Accuracy was evaluated by deviation analysis using 3D image processing software (Geomagic Studio 12, 3D Systems). Kruskal Wallis and Mann-Whitney U tests were performed (P <= .05) for statistical analysis. Results: There were significant differences in the accuracy of digital impressions among intraoral scanners and scanning sequences. The trueness of the Trios scanner and the precision of the Trios, Primescan, and iTero scanners were significantly higher than for the other scanners. The Emerald had the lowest accuracy among the six intraoral scanners tested. Accuracy was affected by scanning sequence when using the Virtuo Vivo, Emerald, Primescan, and iTero. Conclusion: In Kennedy Class I and Class IV partially edentulous cases, it is useful to consider that the intraoral scanner used may affect the accuracy of the digital impression.Article Citation Count: 21Accuracy of single implant scans with a combined healing abutment-scan body system and different intraoral scanners: An in vitro study(Elsevier Sci Ltd, 2021) Cakmak, Gulce; Donmez, Mustafa Borga; Atalay, Sevda; Yilmaz, Hakan; Kokat, Ali Murat; Yilmaz, BurakObjective: The aim of the present study was to evaluate the accuracy of single implant scans with a combined healing abutment-scan body (CHA-SB) system using different intraoral scanners. Methods: A partially edentulous model with an implant was fabricated, and a CHA-SB system was secured on the implant. The model was scanned using an industrial-grade blue light scanner (ATOS Core 80) and a master reference model was generated (MRM). The model was also scanned with 4 different intraoral scanners (IOSs) [(Virtuo Vivo (VV), TRIOS 3 (T3), Omnicam (CO), and Primescan (PS)]. Test scans (n = 8) were superimposed over the MRM using the best fit algorithm (GOM Inspect 2018; GOM GmbH). After superimpositions, distance and angular deviations at selected areas on CHA-SB system were calculated. The data were analyzed with a 1way ANOVA and Tukey HSD tests for trueness and precision (alpha=0.05). Results: The differences in trueness (distance deviations) among tested IOSs were nonsignificant (P=.652). VV presented the highest angular deviations (P <=.031), and the angular deviations in other IOS scans were not found different (P >=.378). The precision of distance deviation data was not significantly different among scanners (P=.052). For the precision of angular deviation data, significant differences were found among IOSs (P=.002). Compared with PS (P=.007) and T3 (P=.014), VV had significantly lower precision, which was not significantly different than that of CO (P=.815). Conclusions: The accuracy (angular deviation) of scans of a combined healing abutment-scan body system on a single implant varied depending on the IOS. VirtuoVivo scans had the lowest accuracy in terms of angular deviations. When the distance deviation data were considered, scan accuracy of scanners was similar. Clinical Significance: A recently introduced combined healing abutment-scan body system combines the acquisition of both the implant and the soft tissue. When different intraoral scanners scan the combined healing abutment-scan body system, the scan accuracy may vary.Article Citation Count: 21Accuracy of six intraoral scanners for scanning complete-arch and 4-unit fixed partial dentures: An in vitro study(Mosby-elsevier, 2022) Diker, Burcu; Tak, OnjenStatement of problem. The digital scan accuracy of different intraoral scanners (IOSs) for long-span fixed prosthesis and the effect of the starting quadrant on accuracy is unclear. Purpose. The purpose of this in vitro study was to evaluate the accuracy of 6 IOSs for complete-arch and prepared teeth digitally isolated from the complete-arch and to determine the effect of the starting quadrant on accuracy. Material and methods. A maxillary model containing bilaterally prepared canines, first molar teeth, and edentulous spans between the prepared teeth was used. The model was scanned by using a highly accurate industrial scanner to create a digital reference data set. Six IOSs were evaluated: TRIOS, iTero, Planmeca Emerald, Cerec Omnicam, Primescan, and Virtuo Vivo. The model was scanned 10 times with each IOS by 1 operator according to the protocols described by the manufacturers. Five scans were made starting from the right quadrant (ScanR), followed by 5 scans starting from the left quadrant (ScanL). All data sets were obtained in standard tessellation language (STL) file format and were used to evaluate accuracy (trueness and precision) with a 3D analyzing software program (Geomagic Studio 12; 3D Systems) by using a best-fit alignment. The prepared teeth were digitally isolated from the complete-arch and evaluated with the analyzing software program. The Kruskal-Wallis and Mann-Whitney U statistical tests were used to detect differences for trueness and precision (alpha=.05). Results. Statistically significant differences were found regarding IOSs (P<.003) and scanning sequence (P<.05). The TRIOS showed the best trueness for the complete-arch, but not statistically different from Primescan, Virtuo Vivo, and iTero (P>.003). The lowest median values for precision of the complete-arch were also found using TRIOS, but no significant difference was found among the scanners (P>.003). In terms of trueness and precision, Primescan had the best accuracy for preparations. Emerald showed significant differences depending on the scanning sequence for complete-arch accuracy. ScanR for trueness (P=.021) and ScanL for precision (P=.004) showed improved results. However, Emerald, TRIOS, and Virtuo Vivo showed statistically significant differences in precision of preparations depending on scanning sequence. ScanL deviated less than ScanR when scanned with TRIOS (P=.025) and Emerald (P=.004), and the opposite with Virtuo Vivo (P=.008). In terms of preparations trueness, no significant difference was found between the ScanR and ScanL of any IOS (P>.05). Conclusions. Based on this in vitro study, the accuracy of the complete-arch and prepared teeth differed according to the IOS and scanning sequence.Article Citation Count: 6The Acute Effects of Different Intensity Whole-Body Vibration Exposure on Muscle Tone and Strength of the Lower Legs, and Hamstring Flexibility: A Pilot Study(Human Kinetics Publ inc, 2021) Saldiran, Tulay Cevik; Atici, Emine; Rezaei, Derya Azim; Ozturk, Ozgul; Uslu, Burcu; Ozcan, Burcu Ates; Okudan, Begum; Fizyoterapi ve Rehabilitasyon / Physiotherapy and RehabilitationContext: The research on the change in properties of the lower leg muscles by different intensity sinusoidal vertical whole-body vibration (SV-WBV) exposures has not yet been investigated. Objective: The purpose of this study was to determine effect of a 20-minute different intensity SV-WBV application to the ankle plantar flexor and dorsiflexor muscles properties and hamstring flexibility. Design: Prospective preintervention-postintervention design. Setting: Physiotherapy department. Participants: A total of 50 recreationally active college-aged individuals with no history of a lower leg injury volunteered. Interventions: The SV-WBV was applied throughout the session with an amplitude of 2 to 4 mm and a frequency of 25 Hz in moderate-intensity vibration group and 40 Hz in a vigorous-intensity vibration group. Main Outcome Measures: The gastrocnemius and tibialis anterior muscle tone was assessed with MyotonPRO, and the strength evaluation was made on the same lower kg muscles using hand-held dynamometer. The sit and reach test was used for the lower leg flexibility evaluation. Results: The gastrocnemius muscle tone decreased on the right side (d = 0.643, P = .01) and increased on the left (d = 0.593, P = .04) when vigorous-intensity vibration was applied. Bilateral gastrocnemius muscle strength did not change in both groups (P> .05). Without differences between groups, bilateral tibialis anterior muscle strength increased in both groups (P < .01). Bilateral gastrocnemius and tibialis anterior muscle tone did not change in the moderate-intensity vibration group (P> .05). Flexibility increased in both groups (P < .01); however, there was no statistically significant difference between the groups (d = 0.169, P = .55). Conclusions: According to study results, if SV-WBV is to be used in hamstring flexibility or ankle dorsiflexor muscle strengthening, both vibration exposures should be preferred. Different vibration programs could be proposed to increase ankle plantar flexor muscle strength in the acute results. Vigorous-intensity vibration exposure is effective in altering ankle plantar flexor muscle tone, but it is important to be aware of the differences between the lower legs.Article Citation Count: 5The acute effects of different intensity whole-body vibration exposure on muscle tone and strength of the lower legs, and hamstring flexibility: A pilot study(Human Kinetics Publishers Inc., 2021) Saldiran,T.; Atici,E.; Rezaei,D.A.; Öztürk,Ö.; Uslu,B.; Özcan,B.A.; Okudan,B.; Fizyoterapi ve Rehabilitasyon / Physiotherapy and RehabilitationContext: The research on the change in properties of the lower leg muscles by different intensity sinusoidal vertical whole-body vibration (SV-WBV) exposures has not yet been investigated. Objective: The purpose of this study was to determine effect of a 20-minute different intensity SV-WBV application to the ankle plantar flexor and dorsiflexor muscles properties and hamstring flexibility. Design: Prospective preintervention-postintervention design. Setting: Physiotherapy department. Participants: A total of 50 recreationally active college-aged individuals with no history of a lower leg injury volunteered. Interventions: The SV-WBV was applied throughout the session with an amplitude of 2 to 4 mm and a frequency of 25 Hz in moderate-intensity vibration group and 40 Hz in a vigorous-intensity vibration group. Main Outcome Measures: The gastrocnemius and tibialis anterior muscle tone was assessed with MyotonPRO, and the strength evaluation was made on the same lower leg muscles using hand-held dynamometer. The sit and reach test was used for the lower leg flexibility evaluation. Results: The gastrocnemius muscle tone decreased on the right side (d=0.643, P=.01) and increased on the left (d = 0.593, P=.04) when vigorous-intensity vibration was applied. Bilateral gastrocnemius muscle strength did not change in both groups (P > .05). Without differences between groups, bilateral tibialis anterior muscle strength increased in both groups (P < .01). Bilateral gastrocnemius and tibialis anterior muscle tone did not change in the moderate-intensity vibration group (P > .05). Flexibility increased in both groups (P < .01); however, there was no statistically significant difference between the groups (d = 0.169, P = .55). Conclusions: According to study results, if SV-WBV is to be used in hamstring flexibility or ankle dorsiflexor muscle strengthening, both vibration exposures should be preferred. Different vibration programs could be proposed to increase ankle plantar flexor muscle strength in the acute results. Vigorous-intensity vibration exposure is effective in altering ankle plantar flexor muscle tone, but it is important to be aware of the differences between the lower legs. © 2021 Human Kinetics, Inc.Review Citation Count: 0Acute spinal epidural hematoma: A case report and review of the literature(Turkish Assoc Trauma Emergency Surgery, 2020) Akar, Ezgi; Ogrenci, Ahmet; Koban, Orkun; Yilmaz, Mesut; Dalbayrak, SedatSpinal epidural hematoma (SEH) is a rare but a significant cause of spinal cord compression and neurologic deficits. Its etiology is usually unknown and requires emergency intervention. The present study aims to review the clinical significance, treatment strategies and clinical outcomes of traumatic SEH with a rare case presentation. Our patient was a 42-year-old female who presented with back pain and loss of sensation and strength in the legs. The patient did not have any disease and did not use anticoagulant drugs. The patient developed numbness in her legs half an hour after having a traditional back walking massage due to occasional back pain. She was paraplegic and anesthetic when seen in our clinic. Thoracic computed tomography (CT) and magnetic resonance imaging (MRI) revealed posterior epidural hemorrhage at Th3-Th4 levels. In the 12th hour, the hematoma was evacuated by an emergency decompressive hemilaminectomy. At the postoperative 24th hour, the patient had symptomatic improvement, and in the sixth month, the patient was mobilized with support. SEH is a rare condition that should be considered in patients with sudden onset of back pain and extremity weakness. Although the gold standard diagnostic tool is MRI, CT is often sufficient to avoid delayed surgery. Immediate surgical decompression (laminectomy/hemilaminectomy) should be performed in cases diagnosed with SEH with neurological deficits.Letter Citation Count: 0Addendum to Spinal Schwannomatosis: Case Report of a Rare Condition(Turkish Neurosurgical Soc, 2017) Hakan, Tayfun; Celikoglu, Erhan; Aker, Fugen; Barisik, Nagehan[No Abstract Available]Article Citation Count: 0Addressing urinary incontinence by gender: a nationwide population-based study in Turkiye(Bmc, 2023) Yavuz, Melike; Etiler, NilayBackgroundUrinary incontinence (UI), which usually occurs in women but affects both sexes, is a significant public health challenge. This study aims to comprehensively investigate the prevalence and determinants of UI in men and women, considering gender-specific factors.MethodsThe study performed a secondary analysis on data obtained from 13,383 individuals surveyed in the 2019 Turkish Health Survey, providing a representation of the Turkish population. The dataset included sociodemographic and health-related variables like UI, body mass index (BMI), physical activity, smoking, and chronic diseases-statistical analysis employed chi-square tests and gender-stratified logistic regression models to identify UI-associated factors.ResultsOur results showed that UI affected 8.8% of the population, with a striking gender disparity. Women had a notably higher prevalence at 11.2%, while men had a lower rate of 5.5%. Importantly, this gender gap narrowed with age. For example, in the 34-44 age group, the female/male ratio was 6.9, but it decreased to 1.4 in the 65-74 age group. Marital status and employment status played significant roles. Separated, divorced, or widowed individuals, particularly women, had the highest prevalence at 19.3%. Employment status influenced UI prevalence, with employed men having the lowest rate (2.1%), while retired women faced the highest rate (15.0%). Higher BMI, especially in obese individuals, significantly raised UI prevalence, reaching 7.9% for men and 15.8% for women. Physical inactivity, notably in women (17.0%), and prolonged sedentary hours (13.9%) were associated with higher UI rates. Former smokers, especially women (15.9%), had a notable impact on UI. Poor perceived health and chronic conditions like Chronic Obstructive Pulmonary Disease (COPD), hypertension, and diabetes were significantly associated with higher UI prevalence. Logistic regression analysis revealed that age, education, perceived health status, COPD, and diabetes were significant factors associated with UI in both sexes, while in women, BMI, physical activity, and smoking also played notable roles.ConclusionsThis extensive UI study has unveiled notable gender disparities and determinants. Notably, these disparities decrease with age, underlining UI's changing nature over time. Modifiable factors impact women more, while non-modifiable factors are linked to men. The study underscores the importance of tailoring healthcare strategies to address UI based on gender.Article Citation Count: 9Adherence to guideline-directed medical and device Therapy in outpAtients with heart failure with reduced ejection fraction: The ATA study(Turkish Soc Cardiology, 2020) Kocabas, Umut; Kivrak, Tarik; Oztekin, Gulsum Meral Yilmaz; Tanik, Veysel Ozan; Ozdemir, Ibrahim Halil; Kaya, Ersin; Pehlivanoglu, SeckinObjective: Despite recommendations from heart failure guidelines on the use of pharmacologic and device therapy in patients with heart failure with reduced ejection fraction (HFrEF), important inconsistencies in guideline adherence persist in practice. The aim of this study was to assess adherence to guideline-directed medical and device therapy for the treatment of patients with chronic HFrEF (left ventricular ejection fraction <= 40%). Methods: The Adherence to guideline-directed medical and device Therapy in outpAtients with HFrEF (ATA) study is a prospective, multicenter, observational study conducted in 24 centers from January 2019 to June 2019. Results: The study included 1462 outpatients (male: 70.1%, mean age: 67 +/- 11 years, mean LVEF: 30%+/- 6%) with chronic HFrEF. Renin-angiotensin system (RAS) inhibitors, beta-blockers, mineralocorticoid receptor antagonists (MRAs), and ivabradin were used in 78.2%, 90.2%, 55.4%, and 12.1% of patients, respectively. The proportion of patients receiving target doses of medical treatments was 24.6% for RAS inhibitors, 9.9% for beta-blockers, and 10.5% for MRAs. Among patients who met the criteria for implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy (CRT), only 16.9% of patients received an ICD (167 of 983) and 34% (95 of 279) of patients underwent CRT (95 of 279). Conclusion: The ATA study shows that most HFrEF outpatients receive RAS inhibitors and beta-blockers but not MRAs or ivabradin when the medical reasons for nonuse, such as drug intolerance or contraindications, are taken into account. In addition, most eligible patients with HFrEF do not receive target doses of pharmacological treatments or guideline-recommended device therapy.Article Citation Count: 7Adjacent Segment Disease (ASD) in Incidental Segmental Fused Vertebra and Comparison With the Effect of Stabilization Systems on ASD(Springernature, 2021) Hekimoglu, Mehdi; Basak, Ahmet; Yilmaz, Atilla; Yildirim, Hakan; Aydin, Ahmet Levent; Karadag, Kursat; ozer, Ali FahirObjective Adjacent segment disease is a controversial process after spine stabilization. The two important factors discussed are natural aging and hypermobility in incidental segmental fusion anomalies; patients have two or more fused vertebrae from birth, which are the results of spinal movement restriction due to the fusion of some spinal units. This article's main purpose is to determine the degree of relationship of hypermobility and the aging process in the deterioration of the disks adjacent to fusion. Methods In this study, the degenerative process developed by hypermobility in the adjacent segment due to incidental segmental fusion was evaluated. The MRI images of 52 adjacent and nonadjacent disks of 45 patients in total were analyzed according to the Pfirrmann grading systems. The average Pfirrmann rating of the disks just above and below the fused segment and the distant first, second, and third non-neighboring levels were evaluated and calculated, respectively. Results The highest rate of incidental fusion is determined on the cervical area with 51.9%, followed by the thoracal area with 32.7%, and the lumbar area with 15.4%. Damage to the adjacent segment disks in cases with incidental fusion can still be seen at any age, with fusion, indicating that the hypermobility effect plays a more prominent role. The evidence of hypermobility without aging is that the segments adjacent to fusion undergo more degeneration than the distant disks. Conclusion Adjacent segment disease is under the influence of many factors. Our findings suggest that its incidence is increasing with the pathological processes initiated by hypermobility. It seems that, at least, it carries equal importance as compared to age. Fusion surgeries damage the adjacent segments under the influence of the passage of time beyond the physiological aging of the patient.Article Citation Count: 1Advancing dentistry: fractal assessment of bone health in pediatric patients with celiac disease using dental images(Quintessence Publishing Co inc, 2023) Bulut, Muge; Tokuc, Muge; Aydin, Merve Nur; Civan, Hasret Ayyildiz; Polat, Esra; Dogan, Guzide; Beser, Omer Faruk; Pedodonti / PedodonticObjectives: To assess the effects of a gluten-free diet on bone structure in children with celiac disease using fractal analysis on panoramic radiographs. Method and materials: A total of 49 patients with celiac disease aged 6 to 13 years, separated into two groups as previously and newly diagnosed, and a control group of 32 healthy individuals were evaluated. In previously and newly diagnosed patients with celiac disease, body mass index Z-scores were calculated, calcium, alkaline phosphatase, vitamin D3, and parathormone levels were measured, and bone mineral density Z-scores were obtained from dual energy x-ray absorpti-ometry. In all patients, the fractal dimensions of the right and left temporomandibular condyles were evaluated with the fractal analysis method on panoramic radiographs. Results: The mean values of serum biomarker levels and the body mass index and bone mineral density Z-scores for both celiac groups were within the normal reference range. No statistically significant difference was determined between right and left condyle fractal dimen-sions values in the three groups examined. In terms of both right and left condyle fractal dimensions values, there was a statis-tically significant difference between groups. The highest fractal dimensions values were determined in the previously diagnosed group. Conclusions: Differences in fractal dimensions values were observed among patients with celiac disease following the glu-ten-free diet. Utilizing fractal analysis on panoramic radiographs can prove valuable for dental practitioners in evaluating bone min-eral density due to its cost-effect iveness, easy accessibility, and reduced radiation exposure for patients, enabling them to provide comprehensive oral health care and potential early interventions for patients with celiac disease. (Quintessence Int 2023;54: 822-831; doi:Article Citation Count: 0Advancing personalized medicine: Integrating statistical algorithms with omics and nano-omics for enhanced diagnostic accuracy and treatment efficacy(Elsevier, 2024) Coskun, Abdurrahman; Ertaylan, Gokhan; Pusparum, Murih; Van Hoof, Rebekka; Kaya, Zelal Zuhal; Khosravi, Arezoo; Zarrabi, Ali; Genetik ve Biyomühendislik / Genetic and Bio-EngineeringMedical laboratory services enable precise measurement of thousands of biomolecules and have become an inseparable part of high-quality healthcare services, exerting a profound influence on global health outcomes. The integration of omics technologies into laboratory medicine has transformed healthcare, enabling personalized treatments and interventions based on individuals' distinct genetic and metabolic profiles. Interpreting laboratory data relies on reliable reference values. Presently, population-derived references are used for individuals, risking misinterpretation due to population heterogeneity, and leading to medical errors. Thus, personalized references are crucial for precise interpretation of individual laboratory results, and the interpretation of omics data should be based on individualized reference values. We reviewed recent advancements in personalized laboratory medicine, focusing on personalized omics, and discussed strategies for implementing personalized statistical approaches in omics technologies to improve global health and concluded that personalized statistical algorithms for interpretation of omics data have great potential to enhance global health. Finally, we demonstrated that the convergence of nanotechnology and omics sciences is transforming personalized laboratory medicine by providing unparalleled diagnostic precision and innovative therapeutic strategies.Article Citation Count: 8Aging Changes of the Superficial Fat Compartments of the Midface Over Time: A Magnetic Resonance Imaging Study(Lippincott Williams & Wilkins, 2020) Cenkeri, Halime Cevik; Guduk, Sukran Sarigul; Cicek, Esin DerinBACKGROUND Studies involving superficial facial fat compartments are few in number with conflicting results. Most of them involved small study groups and compared measurements between different populations of young and old subjects either on cadavers or living subjects. OBJECTIVE To clarify volumetric and dimensional changes in midfacial superficial fat compartment retrospectively in patients who underwent a repeat magnetic resonance imaging (MRI) without gross pathology. MATERIALS AND METHODS A total of 70 patients with a mean age of 60 years (range: 33-82 years) and a median elapsed time of 44.5 months (range: 32-64 months) between 2 MRIs were included. Magnetic resonance imaging scans were analyzed in the axial and sagittal planes to obtain measurements of the medial part of the superficial cheek fat. Superficial cheek fat was divided into 3 compartments. Thickness, width, and height were measured, and volumes were calculated for each compartment on both hemifaces. RESULTS Volume and thickness were decreased significantly in all compartments (p < .05). The width was decreased in superior and middle compartments, whereas increased in lower compartment indicating dislocation of the fat tissue (p < .05). Height was also significantly increased (p < .05). A subgroup analysis has shown that there was no significant difference between men and women. CONCLUSION This study clarifies that aging is associated with a significant decrease in superficial midfacial fat tissue volume and thickness both in women and men. The decrease in width in upper and middle compartments, but increase in lower compartment suggests a volume shift within superficial fat tissue.Article Citation Count: 1Air Injection and Transillumination in Phonosurgery: A Novel Technique(Mosby-elsevier, 2020) Kocak, Ismail; Alkan, Zeynep; Ovunc, OkanObjectives/Hypothesis. The goal of this study was to introduce two novel techniques in phonomicrosurgery, air injection (AIR), and transillumination (TI), to improve the diagnosis and surgical excision of pathological tissue in vocal folds during suspension laryngoscopy while preserving the healthy tissue as much as possible. Study design. Prospective clinical case series. Methods. Thirty-four patients with benign vocal cord lesions who underwent phonomicrosurgery between January 2016 and May 2017 were evaluated. Pre- and intraoperative recordings were evaluated by three experienced laryngologists. Stroboscopic video images taken during the preoperative diagnosis and interoperative video recordings made before and after AIR and TI were performed were reviewed and compared. During the preoperative evaluation, the surgeons declared their surgical plans and noted changes while observing the intraoperative evaluation during AIR and TI. Results. Sixty-eight vocal folds were evaluated. The initial diagnosis was found to be consistent with the final diagnosis in only 10 patients (29.4%). The diagnoses of 29 vocal folds (42.6%) and the surgical plans changed after AIR and TI. In six cases, submucosal bands, additional morphological structures in the vicinity of the primary pathology, were observed; these could only be visualized with AIR and TI. AIR and TI revealed new pathologies in four vocal folds that were noted to be normal in the preoperative evaluation. Conclusion. AIR and TI are useful and promising techniques to identify undiagnosed lesions in vocal folds and to increase the success of minimally invasive phonosurgery.Article Citation Count: 8Airborne pathogen projection during ophthalmic examination(Springer, 2020) Bostanci Ceran, Basak; Karakoc, Alp; Taciroglu, ErtugrulPurpose Microscale droplets act as coronaviruses (CoV) carriers in the air when released from an infected person and may infect others during close contact such as ophthalmic examination. The main objective of the present work is to demonstrate how CoV deposited droplets are projected during biomicroscopy and to discuss what kind of precautions should be taken in ophthalmic practice. Methods A coupled fluid-structure system comprising smoothed particle hydrodynamics and the finite element method has been built to assess the projection of droplets spreading from an infected person. Different conditions based on the maximum exit flow velocity from the infector's mouth during the ophthalmic examination were modeled. Results During exhalation, for which the exit flow is similar to 1000 mm/s, the average horizontal distance of the flow front was similar to 200 mm while individual particles can reach up to similar to 500 mm. In case of coughing or sneezing (corresponding to an exit flow of similar to 12,000 mm/s), the average horizontal distance of the flow front was similar to 1300 mm. Conclusion During the ophthalmic examination, the proximity to the patient's nose and mouth was observed to be less than the horizontal distance of flow front particles. Even though mounted breath shields are used, particles flew beyond the shield and contaminate the ophthalmologist. Compared with the current protective breath shields, the use of a larger shield with a minimum radius of 18 cm is needed to decrease viral transmission.