Refractive results, visual quality and patient satisfaction with a new trifocal intraocular lens design

dc.contributor.authorHasan Basri ARİFOĞLU
dc.contributor.authorSerdar ÖZATEŞ
dc.contributor.authorEmin Emrullah TAŞINDI
dc.contributor.authorBaşak BOSTANCI CERAN
dc.date.accessioned2024-05-25T12:20:16Z
dc.date.available2024-05-25T12:20:16Z
dc.date.issued2020
dc.departmentOkan Universityen_US
dc.department-tempOkan Üniversitesi, Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, İstanbul, Türkiye Okan Üniversitesi, Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, İstanbul, Türkiye Okan Üniversitesi, Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, İstanbul, Türkiye Okan Üniversitesi, Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, İstanbul, Türkiyeen_US
dc.description.abstractAim: To evaluate the outcomes after bilateral implantation of a new trifocal intraocular lens (IOL).Materials and Methods: The study included patients with visually significant cataract that underwent bilateral implantation of theAcriva Trinova Sinusoidal Trifocal IOL. The preoperative corrected distance visual acuity (CDVA) and postoperative uncorrecteddistance visual acuity (UDVA), CDVA, uncorrected intermediate (UIVA) and near visual acuities (UNVA) along with manifest refractionswere assessed at 1 month and 6 months after cataract surgery. The defocus curve and contrast sensitivity (CS) were evaluated atthe 6th month visit. Patient satisfaction and incidence of dysphotopic symptoms were assessed.Results: The study enrolled a total of 60 eyes of 30 patients, 10 males and 20 females aged 61.78± 8.73 years (range, 45 to 78 years).90% of the patients (n: 27) achieved a binocular UIVA of 0.1 LogMAR or better at the 6-month visit while, 96.7% (n:29) patients hada binocular UNVA of 0.1 LogMAR or better in the same postoperative visit. The CS results were within the the range of normalityat 6 months post-surgery. 6.7% of patients reported marked halo around light sources and 3.3% reported glare that interferes withnighttime driving. 96.6% of the patients reported spectacle independence for all distances and rated their visual function and qualitysatisfactory at all distances.Conclusion: Bilateral implantation of the Acriva Trinova Sinusoidal Trifocal IOL seems to provide effective restoration of visualfunction at all distances after cataract surgery in the majority of patients. Contrast sensitivity results and low incidence of dysphotopicphenomena might be associated with high patient satisfaction.en_US
dc.identifier.citation0
dc.identifier.doi10.5455/annalsmedres.2020.08.852
dc.identifier.endpage3023en_US
dc.identifier.issn2636-7688
dc.identifier.issue11en_US
dc.identifier.startpage3018en_US
dc.identifier.trdizinid421588
dc.identifier.urihttps://doi.org/10.5455/annalsmedres.2020.08.852
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/421588/refractive-results-visual-quality-and-patient-satisfaction-with-a-new-trifocal-intraocular-lens-design
dc.identifier.urihttps://hdl.handle.net/20.500.14517/1870
dc.identifier.volume27en_US
dc.language.isoen
dc.relation.ispartofAnnals of Medical Researchen_US
dc.relation.publicationcategoryDiğeren_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleRefractive results, visual quality and patient satisfaction with a new trifocal intraocular lens designen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files