A novel Iron(III)-selective membrane potentiometric sensor based on 5-chloro-3-[4-(trifluoromethoxy) phenylimino] indolin-2-one
dc.authorscopusid | 55910480000 | |
dc.authorscopusid | 56470686700 | |
dc.authorscopusid | 6507692468 | |
dc.authorscopusid | 35518926800 | |
dc.contributor.author | Demir,E. | |
dc.contributor.author | Kemer,B. | |
dc.contributor.author | Bekircan,O. | |
dc.contributor.author | Aboul-Enein,H.Y. | |
dc.date.accessioned | 2024-05-25T12:32:03Z | |
dc.date.available | 2024-05-25T12:32:03Z | |
dc.date.issued | 2015 | |
dc.department | Okan University | en_US |
dc.department-temp | Demir E., Okan University, Vocational School of Health Services, Perfusion Techniques, Istanbul, 34959, Turkey; Kemer B., Karadeniz Technical University, Department of Chemistry, Trabzon, 61100, Turkey; Bekircan O., Karadeniz Technical University, Department of Chemistry, Trabzon, 61100, Turkey; Aboul-Enein H.Y., Pharmaceutical and Medicinal Chemistry Department, Pharmaceutical and Drug Industries Research Division, National Research Centre, Dokki, Cairo, 12311, Egypt | en_US |
dc.description.abstract | A novel polyvinyl chloride (PVC) membrane sensor that is highly selective to Fe3+ ions was prepared by using 5-chloro-3-[4-(trifluoromethoxy)phenylimino]indolin-2-one (CFMEPI) ionophore. The sensor exhibits a Nernstian response for Fe3+ ions over a wide concentration range (1.0 ×10-2 −1.0×10-6M) with a slope of 46.7±0.5 mV per decade. The sensor has a response time of 20s and can be used for at least 3 months without any measurable divergence in potential. It was concluded that the sensor response was pH independent in the range of 4.0-8.61. The sensor has some advantages such as short analysis time, particularly high selectivity towards iron (III). The sensor was used successfully for direct determination of Fe3+ in several synthetic and real samples with satisfactory results. © 2015 Bentham Science Publishers. | en_US |
dc.identifier.citation | 12 | |
dc.identifier.doi | 10.2174/1573411010666141111224325 | |
dc.identifier.endpage | 35 | en_US |
dc.identifier.issn | 1573-4110 | |
dc.identifier.issue | 1 | en_US |
dc.identifier.scopus | 2-s2.0-84920527683 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 29 | en_US |
dc.identifier.uri | https://doi.org/10.2174/1573411010666141111224325 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14517/2334 | |
dc.identifier.volume | 11 | en_US |
dc.identifier.wosquality | Q3 | |
dc.language.iso | en | |
dc.publisher | Bentham Science Publishers | en_US |
dc.relation.ispartof | Current Analytical Chemistry | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | All-solid-state | en_US |
dc.subject | Determination of Fe<sup>3+</sup> | en_US |
dc.subject | Fe<sup>3+</sup>-selective electrode | en_US |
dc.subject | Potentiometer | en_US |
dc.subject | PVC membrane | en_US |
dc.title | A novel Iron(III)-selective membrane potentiometric sensor based on 5-chloro-3-[4-(trifluoromethoxy) phenylimino] indolin-2-one | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |