EFFECTS OF SODIUM HYPOCHLORIDE ON CYCLIC FATIGUE RESISTANCE OF BIORACE ROTARY INSTRUMENT WITH DIFFERENT TIP SIZES
dc.contributor.author | Burçin ARICAN | |
dc.contributor.author | Ayfer ATAV ATEŞ | |
dc.date.accessioned | 2024-05-25T12:20:17Z | |
dc.date.available | 2024-05-25T12:20:17Z | |
dc.date.issued | 2020 | |
dc.department | Okan University | en_US |
dc.department-temp | İstanbul Okan Üniversitesi, Diş Hekimliği Fakültesi, Endodonti Anabilim Dalı, İstanbul, Türkiye İstanbul Okan Üniversitesi, Diş Hekimliği Fakültesi, Endodonti Anabilim Dalı, İstanbul, Türkiye | en_US |
dc.description.abstract | Aim:The aim of the present study was to determine the effect of sodium hypochloride solution on the cyclic fatigue resistance of BioRace (BR) NiTi instrument with different tip size.Methods:Eighty BioRace instrument with two different size (BR4-35.04 and BR5-40.04) were used. These instruments were randomly divided into four group, each containing 20 files. The cyclicfatigue resistance were than tested in the following conditions; group 1, BR 4 with no immersion; group 2, BR 4 with dynamic immersion in 5.25% NaOCl at 37°C ± 1°C for 5 minute; group 3, BR 5 with no immersion; group 4, BR 5 with dynamic immersion in 5.25% NaOCl at 37°C ± 1°C for 5 minute. Then the instruments were used in stainless steel artificial root canal with a curvature of 60° and 5 mm radius. Number of cycle to failure (NCF) were measured for each group. The time to failure (TTF) in seconds werealso recorded. Data were subjected to the statistical analysis.Results: Nonimmersion groups were statistically superior to immersion groups (group1>group 2 and group 3>group4) both regarding TTF and NCF. However, no significant difference was found between instruments with different tip size regardless of the immersion procedure.Conclusion:The cyclic fatigue resistance of BR instrument was affected by NaOCl immersion but not with tip size. | en_US |
dc.identifier.citation | 0 | |
dc.identifier.doi | 10.17567/ataunidfd.780113 | |
dc.identifier.endpage | 598 | en_US |
dc.identifier.issn | 1300-9044 | |
dc.identifier.issue | 4 | en_US |
dc.identifier.startpage | 594 | en_US |
dc.identifier.trdizinid | 412199 | |
dc.identifier.uri | https://doi.org/10.17567/ataunidfd.780113 | |
dc.identifier.uri | https://search.trdizin.gov.tr/tr/yayin/detay/412199/effects-of-sodium-hypochloride-on-cyclic-fatigue-resistance-of-biorace-rotary-instrument-with-different-tip-sizes | |
dc.identifier.uri | https://hdl.handle.net/20.500.14517/1877 | |
dc.identifier.volume | 30 | en_US |
dc.language.iso | en | |
dc.relation.ispartof | Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi | en_US |
dc.relation.publicationcategory | Diğer | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.title | EFFECTS OF SODIUM HYPOCHLORIDE ON CYCLIC FATIGUE RESISTANCE OF BIORACE ROTARY INSTRUMENT WITH DIFFERENT TIP SIZES | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |