Valuations of Adaptive Methods for Filtering Out High-Noises in Oil Complexes Telemetry Systems

No Thumbnail Available

Date

2013

Journal Title

Journal ISSN

Volume Title

Publisher

Ieee

Open Access Color

OpenAIRE Downloads

OpenAIRE Views

Research Projects

Organizational Units

Journal Issue

Abstract

The ESP telemetry system needs to receive accurate information on the pump unit's intake pressure, temperature and most importantly the electric motor stator cooling oil insulation resistance, for the successful exploitation of the ESP. The increasing disturbance levels with the corrupted analog telemetry signal are resulting in increasing noise levels; however, often it is still audible or the control system is still reliable. Beyond a certain disturbance level - digital cliff, the digital telemetry signal and control may stop abruptly. From ten applied adaptive filter algorithms, only three have shown successfully good results in the early prediction of the ESP electric motor real insulation disruption.

Description

Ustun, Ozgur/0000-0002-2039-2609; Yilmaz, Murat/0000-0003-1584-1788

Keywords

Submersible electric motor, adaptive filtering, oil industry, noise, communication-telemetry channels

Turkish CoHE Thesis Center URL

Fields of Science

Citation

0

WoS Q

Scopus Q

Source

7th International Conference on Application of Information and Communication Technologies (AICT) -- OCT 23-25, 2013 -- Baku, AZERBAIJAN

Volume

Issue

Start Page

304

End Page

308