Valuations of Adaptive Methods for Filtering Out High-Noises in Oil Complexes Telemetry Systems
No Thumbnail Available
Date
2013
Journal Title
Journal ISSN
Volume Title
Publisher
Ieee
Open Access Color
OpenAIRE Downloads
OpenAIRE Views
Abstract
The ESP telemetry system needs to receive accurate information on the pump unit's intake pressure, temperature and most importantly the electric motor stator cooling oil insulation resistance, for the successful exploitation of the ESP. The increasing disturbance levels with the corrupted analog telemetry signal are resulting in increasing noise levels; however, often it is still audible or the control system is still reliable. Beyond a certain disturbance level - digital cliff, the digital telemetry signal and control may stop abruptly. From ten applied adaptive filter algorithms, only three have shown successfully good results in the early prediction of the ESP electric motor real insulation disruption.
Description
Ustun, Ozgur/0000-0002-2039-2609; Yilmaz, Murat/0000-0003-1584-1788
Keywords
Submersible electric motor, adaptive filtering, oil industry, noise, communication-telemetry channels
Turkish CoHE Thesis Center URL
Fields of Science
Citation
0
WoS Q
Scopus Q
Source
7th International Conference on Application of Information and Communication Technologies (AICT) -- OCT 23-25, 2013 -- Baku, AZERBAIJAN
Volume
Issue
Start Page
304
End Page
308