The influences of artery radii and stenosis severity on the thermal behavior of blood by employing Sisko and Lumen models: Numerical study

dc.authorscopusid23488650600
dc.authorscopusid59203567600
dc.authorscopusid23028598900
dc.authorscopusid57204003931
dc.authorscopusid57021730500
dc.authorscopusid57449950600
dc.contributor.authorGataa,I.S.
dc.contributor.authorSalahshour, Soheıl
dc.contributor.authorSalahshour,S.
dc.contributor.authorYazdekhasti,A.
dc.contributor.authorAL-Hamairy,A.K.
dc.contributor.authorBaghaei,S.
dc.date.accessioned2024-09-11T07:43:01Z
dc.date.available2024-09-11T07:43:01Z
dc.date.issued2024
dc.departmentOkan Universityen_US
dc.department-tempGataa I.S., Warith Al-Anbiyaa University, Karbala, 56001, Iraq; Mohammed A.A., Department of Medical Devices Technology Engineering, Al-Amarah University College, Maysan, Iraq; Salahshour S., Faculty of Engineering and Natural Sciences, Istanbul Okan University, Istanbul, Turkey, Faculty of Engineering and Natural Sciences, Bahcesehir University, Istanbul, Turkey, Department of Computer Science and Mathematics, Lebanese American University, Beirut, Lebanon; Yazdekhasti A., Department of Mechanical Engineering, Isfahan University of Technology, Isfahan, 84156-83111, Iran; AL-Hamairy A.K., Anesthesia Techniques Department, College of Health and Medical Techniques, Al-Mustaqbal University, Babylon, 51001, Iraq; Baghaei S., Department of mechanical engineering, Khomeinishahr branch, Islamic Azad University, Khomeinishahr, Iranen_US
dc.description.abstractArtery stenosis occurs when blood vessels do not supply enough blood and oxygen due to blockage by a fatty mass called plaque. In this work, the influence of stenosis on the Nusselt number (Nu) for non-Newtonian blood flow is studied by the FVM method and using fluent software. Also, the artery is simulated based on the Lumen model. In this research, at first, it is assumed that stenosis severity increases as much as 20 %, 30 %, and 40 % of the internal cross-section area of the artery respectively while the radius is constant, then the stenosis severity is fixed at 40 %, and only radius of artery increases from 0.002 m to 0.0025, 0.0030, and 0.0035 m. The artery wall is affected by constant heat flux and Nusselt numbers in every stage as a significant parameter in each flow are calculated. It should be mentioned that the Nusselt numbers are achieved both in the direction of flow and perpendicular to one. The results show that an increase of stenosis severity from 20 % to 40 % and a decrease of the artery radius between 0.002 and 0.0035 m leads to Nusselt number enhancement due to acceleration of blood flow and increase of heat transfer while the maximum values of Nusselt number remain no change approximately. Therefore, influences of stenosis size on the thermal behavior of blood in the artery are not noticeable, and thermal risks are ignorable. © 2024 The Author(s)en_US
dc.identifier.citation1
dc.identifier.doi10.1016/j.ijft.2024.100776
dc.identifier.issn2666-2027
dc.identifier.scopus2-s2.0-85200646083
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.ijft.2024.100776
dc.identifier.urihttps://hdl.handle.net/20.500.14517/6282
dc.identifier.volume23en_US
dc.institutionauthorSalahshour, Soheıl
dc.institutionauthorSalahshour S.
dc.language.isoen
dc.publisherElsevier B.V.en_US
dc.relation.ispartofInternational Journal of Thermofluidsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBlood behavioren_US
dc.subjectSisko formulationen_US
dc.subjectStenosisen_US
dc.titleThe influences of artery radii and stenosis severity on the thermal behavior of blood by employing Sisko and Lumen models: Numerical studyen_US
dc.typeArticleen_US
dspace.entity.typePublication
relation.isAuthorOfPublicationf5ba517c-75fb-4260-af62-01c5f5912f3d
relation.isAuthorOfPublication.latestForDiscoveryf5ba517c-75fb-4260-af62-01c5f5912f3d

Files