Refractive results, visual quality and patient satisfaction with a new trifocal intraocular lens design

dc.contributor.author Hasan Basri ARİFOĞLU
dc.contributor.author Serdar ÖZATEŞ
dc.contributor.author Emin Emrullah TAŞINDI
dc.contributor.author Başak BOSTANCI CERAN
dc.date.accessioned 2024-05-25T12:20:16Z
dc.date.available 2024-05-25T12:20:16Z
dc.date.issued 2020
dc.department Okan University en_US
dc.department-temp Okan Üniversitesi, Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, İstanbul, Türkiye Okan Üniversitesi, Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, İstanbul, Türkiye Okan Üniversitesi, Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, İstanbul, Türkiye Okan Üniversitesi, Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, İstanbul, Türkiye en_US
dc.description.abstract Aim: To evaluate the outcomes after bilateral implantation of a new trifocal intraocular lens (IOL).Materials and Methods: The study included patients with visually significant cataract that underwent bilateral implantation of theAcriva Trinova Sinusoidal Trifocal IOL. The preoperative corrected distance visual acuity (CDVA) and postoperative uncorrecteddistance visual acuity (UDVA), CDVA, uncorrected intermediate (UIVA) and near visual acuities (UNVA) along with manifest refractionswere assessed at 1 month and 6 months after cataract surgery. The defocus curve and contrast sensitivity (CS) were evaluated atthe 6th month visit. Patient satisfaction and incidence of dysphotopic symptoms were assessed.Results: The study enrolled a total of 60 eyes of 30 patients, 10 males and 20 females aged 61.78± 8.73 years (range, 45 to 78 years).90% of the patients (n: 27) achieved a binocular UIVA of 0.1 LogMAR or better at the 6-month visit while, 96.7% (n:29) patients hada binocular UNVA of 0.1 LogMAR or better in the same postoperative visit. The CS results were within the the range of normalityat 6 months post-surgery. 6.7% of patients reported marked halo around light sources and 3.3% reported glare that interferes withnighttime driving. 96.6% of the patients reported spectacle independence for all distances and rated their visual function and qualitysatisfactory at all distances.Conclusion: Bilateral implantation of the Acriva Trinova Sinusoidal Trifocal IOL seems to provide effective restoration of visualfunction at all distances after cataract surgery in the majority of patients. Contrast sensitivity results and low incidence of dysphotopicphenomena might be associated with high patient satisfaction. en_US
dc.identifier.citationcount 0
dc.identifier.doi 10.5455/annalsmedres.2020.08.852
dc.identifier.endpage 3023 en_US
dc.identifier.issn 2636-7688
dc.identifier.issue 11 en_US
dc.identifier.startpage 3018 en_US
dc.identifier.trdizinid 421588
dc.identifier.uri https://doi.org/10.5455/annalsmedres.2020.08.852
dc.identifier.uri https://search.trdizin.gov.tr/tr/yayin/detay/421588/refractive-results-visual-quality-and-patient-satisfaction-with-a-new-trifocal-intraocular-lens-design
dc.identifier.uri https://hdl.handle.net/20.500.14517/1870
dc.identifier.volume 27 en_US
dc.language.iso en
dc.relation.ispartof Annals of Medical Research en_US
dc.relation.publicationcategory Diğer en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.title Refractive results, visual quality and patient satisfaction with a new trifocal intraocular lens design en_US
dc.type Article en_US