A Novel Iron(III)-Selective Membrane Potentiometric Sensor Based on 5-Chloro-3-[4-(trifluoromethoxy) phenylimino] Indolin-2-one

dc.authorid Demir, Ersin/0000-0001-9180-0609
dc.authorwosid Demir, Ersin/V-6633-2019
dc.authorwosid Bekircan, Olcay/AAB-4173-2021
dc.contributor.author Demir, Ersin
dc.contributor.author Kemer, Baris
dc.contributor.author Bekircan, Olcay
dc.contributor.author Aboul-Enein, Hassan Y.
dc.date.accessioned 2024-10-15T20:19:04Z
dc.date.available 2024-10-15T20:19:04Z
dc.date.issued 2015
dc.department Okan University en_US
dc.department-temp [Demir, Ersin] Okan Univ, Vocat Sch Hlth Serv, Perfus Tech, TR-34959 Istanbul, Turkey; [Kemer, Baris; Bekircan, Olcay] Karadeniz Tech Univ, Fac Sci, Dept Chem, TR-61100 Trabzon, Turkey; [Aboul-Enein, Hassan Y.] Natl Res Ctr, Pharmaceut & Med Chem Dept, Pharmaceut & Drug Ind Res Div, Cairo 12311, Egypt en_US
dc.description Demir, Ersin/0000-0001-9180-0609 en_US
dc.description.abstract A novel polyvinyl chloride (PVC) membrane sensor that is highly selective to Fe3+ ions was prepared by using 5-chloro-3-[4-(trifluoromethoxy) phenylimino] indolin-2-one (CFMEPI) ionophore. The sensor exhibits a Nernstian response for Fe3+ ions over a wide concentration range (1.0 x10(-2) -1.0x10(-6)M) with a slope of 46.7 +/- 0.5 mV per decade. The sensor has a response time of 20s and can be used for at least 3 months without any measurable divergence in potential. It was concluded that the sensor response was pH independent in the range of 4.0-8.61. The sensor has some advantages such as short analysis time, particularly high selectivity towards iron (III). The sensor was used successfully for direct determination of Fe3+ in several synthetic and real samples with satisfactory results. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.citationcount 11
dc.identifier.endpage 35 en_US
dc.identifier.issn 1573-4110
dc.identifier.issn 1875-6727
dc.identifier.issue 1 en_US
dc.identifier.scopusquality Q2
dc.identifier.startpage 29 en_US
dc.identifier.uri https://hdl.handle.net/20.500.14517/6422
dc.identifier.volume 11 en_US
dc.identifier.wos WOS:000350480400004
dc.identifier.wosquality Q3
dc.language.iso en
dc.publisher Bentham Science Publ Ltd en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Fe3+-selective electrode en_US
dc.subject PVC membrane en_US
dc.subject All-solid-state en_US
dc.subject determination of Fe3+ en_US
dc.subject potentiometer en_US
dc.title A Novel Iron(III)-Selective Membrane Potentiometric Sensor Based on 5-Chloro-3-[4-(trifluoromethoxy) phenylimino] Indolin-2-one en_US
dc.type Article en_US
dc.wos.citedbyCount 11

Files