Shaping efficiency of waveone gold and one curve in simulated j-shaped root canals

dc.authorscopusid 57204595215
dc.authorscopusid 56094357600
dc.contributor.author Ates,A.A.
dc.contributor.author Arıcan,B.
dc.date.accessioned 2024-05-25T12:34:10Z
dc.date.available 2024-05-25T12:34:10Z
dc.date.issued 2021
dc.department Okan University en_US
dc.department-temp Ates A.A., Department of Endodontics, Faculty of Dentistry, Istanbul Okan University, Istanbul, Turkey; Arıcan B., Department of Endodontics, Faculty of Dentistry, Istanbul Okan University, Istanbul, Turkey en_US
dc.description.abstract To evaluate the shaping efficiency of WaveOne Gold (WOG; Dentsply Sirona, Ballaigues, Switzerland) and One Curve (OC; Micro-Mega, Besancon, France) in J-shaped resin blocks. Forty simulated J-shaped root canals with 0.15 mm apical diameters and 2 % taper were divided into two groups (n=20) as follows; WOGG/WOG (25.07) group (glide path was created with WaveOne Gold Glider) and OneG/OC (25.06) (glide path was created with One G) group. The pre-and post-instrumentation images were taken, and the transportation value (TV), centering ability (CA) and the total amount of resin removed (TRR) were calculated by using the superimposition of the images. These parameters calculated with Image J Software Program based on 18 reference points with 1-mm intervals of the canal. The data were analyzed with Kruskal-Wallis and than Dunn's multiple comparison tests. The significance level was set at P ≤.05. There was no statistically significant difference among OG/OC and WOG/WOGG groups' apical (points 1-3), middle (points 4-6), and coronal (points 7-9) sections in terms of both TV and TRR. The centering ability of the instruments was decreased in the curvature part (middle section) of the canals. While WOG group showed better centering ability at points 6-7, OC group exhibited better result at point 2. It was shown that WaveOne Gold and One Curve, which are single-file systems, could be used safely in J-shaped root canals with their glide path files. © 2021, Yuzuncu Yil Universitesi Tip Fakultesi. All rights reserved. en_US
dc.identifier.citationcount 0
dc.identifier.doi 10.5505/ejm.2021.04710
dc.identifier.endpage 247 en_US
dc.identifier.issn 1301-0883
dc.identifier.issue 2 en_US
dc.identifier.scopus 2-s2.0-85104187512
dc.identifier.scopusquality Q4
dc.identifier.startpage 242 en_US
dc.identifier.trdizinid 411971
dc.identifier.uri https://doi.org/10.5505/ejm.2021.04710
dc.identifier.uri https://hdl.handle.net/20.500.14517/2552
dc.identifier.volume 26 en_US
dc.language.iso en
dc.publisher Yuzuncu Yil Universitesi Tip Fakultesi en_US
dc.relation.ispartof Eastern Journal of Medicine en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.scopus.citedbyCount 0
dc.subject Glide path en_US
dc.subject OneCurve en_US
dc.subject Resin blocks en_US
dc.subject Rotary instruments en_US
dc.subject WaveOne Gold en_US
dc.title Shaping efficiency of waveone gold and one curve in simulated j-shaped root canals en_US
dc.type Article en_US

Files