Fe<SUP>3+</SUP> - Ion Selective Electrode Developed as a Detector in Flow Injection Analysis
dc.authorid | Demir, Ersin/0000-0001-9180-0609 | |
dc.authorid | isildak, ibrahim/0000-0001-9654-1386 | |
dc.authorscopusid | 55910480000 | |
dc.authorscopusid | 56470686700 | |
dc.authorscopusid | 6603596907 | |
dc.authorscopusid | 35518926800 | |
dc.authorwosid | Demir, Ersin/V-6633-2019 | |
dc.contributor.author | Demir, Ersin | |
dc.contributor.author | Kemer, Baris | |
dc.contributor.author | Isildak, Ibrahim | |
dc.contributor.author | Aboul-Enein, Hassan Y. | |
dc.date.accessioned | 2024-05-25T11:18:02Z | |
dc.date.available | 2024-05-25T11:18:02Z | |
dc.date.issued | 2015 | |
dc.department | Okan University | en_US |
dc.department-temp | [Demir, Ersin] Okan Univ, Vocat Sch Hlth Serv, Perfus Tech, TR-34959 Istanbul, Turkey; [Kemer, Baris] Karadeniz Tech Univ, Fac Sci, Dept Chem, TR-61100 Trabzon, Turkey; [Isildak, Ibrahim] Yildiz Tech Univ, Fac Chem & Met Engn, Dept Bioengn, TR-34210 Istanbul, Turkey; [Aboul-Enein, Hassan Y.] Natl Res Ctr, Pharmaceut & Med Chem Dept, Pharmaceut & Drug Ind Res Div, Giza 12662, Egypt | en_US |
dc.description | Demir, Ersin/0000-0001-9180-0609; isildak, ibrahim/0000-0001-9654-1386 | en_US |
dc.description.abstract | A new polyvinyl chloride (PVC) membrane Fe3+ - ion selective electrode was constructed as a detector for the analysis Fe3+ using a home-made low-volume flow through cell. Optimum working conditions for the flow injection analysis (FIA) measurements were examined. In addition, under optimum conditions, potentiometric performance characteristics of the Fe3+ ion-selective electrode were investigated. Electrode had a linear response in the concentration range of 1.0 x 10(-3)-1.0 x 10(-6) M (R-2=0.9961, y=24.7+772.0). Reproducibility of the electrode responses was very satisfied. The potential of Fe3+ ion selective electrode was decreased intra and inter day 0.9 % and 3.7% respectively. The designed flow-through cell system as Fe3+ detector revealed sampling rates of approximately 50 injections per hour. The obtained results in FIA were in a good agreement with AAs results at % 95 confidence level for each syrups. | en_US |
dc.identifier.citation | 3 | |
dc.identifier.doi | 10.2174/1573411011666150128193424 | |
dc.identifier.endpage | 108 | en_US |
dc.identifier.issn | 1573-4110 | |
dc.identifier.issn | 1875-6727 | |
dc.identifier.issue | 2 | en_US |
dc.identifier.scopus | 2-s2.0-84936746957 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 104 | en_US |
dc.identifier.uri | https://doi.org/10.2174/1573411011666150128193424 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14517/282 | |
dc.identifier.volume | 11 | en_US |
dc.identifier.wos | WOS:000350481300004 | |
dc.identifier.wosquality | Q3 | |
dc.language.iso | en | |
dc.publisher | Bentham Science Publ Ltd | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Iron-selective electrode | en_US |
dc.subject | determination | en_US |
dc.subject | flow injection system | en_US |
dc.subject | potentiometer | en_US |
dc.subject | syrups analysis | en_US |
dc.title | Fe<SUP>3+</SUP> - Ion Selective Electrode Developed as a Detector in Flow Injection Analysis | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |