Fe<SUP>3+</SUP> - Ion Selective Electrode Developed as a Detector in Flow Injection Analysis

dc.authoridDemir, Ersin/0000-0001-9180-0609
dc.authoridisildak, ibrahim/0000-0001-9654-1386
dc.authorscopusid55910480000
dc.authorscopusid56470686700
dc.authorscopusid6603596907
dc.authorscopusid35518926800
dc.authorwosidDemir, Ersin/V-6633-2019
dc.contributor.authorDemir, Ersin
dc.contributor.authorKemer, Baris
dc.contributor.authorIsildak, Ibrahim
dc.contributor.authorAboul-Enein, Hassan Y.
dc.date.accessioned2024-05-25T11:18:02Z
dc.date.available2024-05-25T11:18:02Z
dc.date.issued2015
dc.departmentOkan Universityen_US
dc.department-temp[Demir, Ersin] Okan Univ, Vocat Sch Hlth Serv, Perfus Tech, TR-34959 Istanbul, Turkey; [Kemer, Baris] Karadeniz Tech Univ, Fac Sci, Dept Chem, TR-61100 Trabzon, Turkey; [Isildak, Ibrahim] Yildiz Tech Univ, Fac Chem & Met Engn, Dept Bioengn, TR-34210 Istanbul, Turkey; [Aboul-Enein, Hassan Y.] Natl Res Ctr, Pharmaceut & Med Chem Dept, Pharmaceut & Drug Ind Res Div, Giza 12662, Egypten_US
dc.descriptionDemir, Ersin/0000-0001-9180-0609; isildak, ibrahim/0000-0001-9654-1386en_US
dc.description.abstractA new polyvinyl chloride (PVC) membrane Fe3+ - ion selective electrode was constructed as a detector for the analysis Fe3+ using a home-made low-volume flow through cell. Optimum working conditions for the flow injection analysis (FIA) measurements were examined. In addition, under optimum conditions, potentiometric performance characteristics of the Fe3+ ion-selective electrode were investigated. Electrode had a linear response in the concentration range of 1.0 x 10(-3)-1.0 x 10(-6) M (R-2=0.9961, y=24.7+772.0). Reproducibility of the electrode responses was very satisfied. The potential of Fe3+ ion selective electrode was decreased intra and inter day 0.9 % and 3.7% respectively. The designed flow-through cell system as Fe3+ detector revealed sampling rates of approximately 50 injections per hour. The obtained results in FIA were in a good agreement with AAs results at % 95 confidence level for each syrups.en_US
dc.identifier.citation3
dc.identifier.doi10.2174/1573411011666150128193424
dc.identifier.endpage108en_US
dc.identifier.issn1573-4110
dc.identifier.issn1875-6727
dc.identifier.issue2en_US
dc.identifier.scopus2-s2.0-84936746957
dc.identifier.scopusqualityQ2
dc.identifier.startpage104en_US
dc.identifier.urihttps://doi.org/10.2174/1573411011666150128193424
dc.identifier.urihttps://hdl.handle.net/20.500.14517/282
dc.identifier.volume11en_US
dc.identifier.wosWOS:000350481300004
dc.identifier.wosqualityQ3
dc.language.isoen
dc.publisherBentham Science Publ Ltden_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectIron-selective electrodeen_US
dc.subjectdeterminationen_US
dc.subjectflow injection systemen_US
dc.subjectpotentiometeren_US
dc.subjectsyrups analysisen_US
dc.titleFe<SUP>3+</SUP> - Ion Selective Electrode Developed as a Detector in Flow Injection Analysisen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files