A novel potentiometric pH electrode based on sulfated natural Fe<sub>3</sub>O<sub>4</sub> and analytical application in food samples

dc.authoridDemir, Ersin/0000-0001-9180-0609
dc.authorscopusid56470686700
dc.authorscopusid55910480000
dc.authorwosidDemir, Ersin/V-6633-2019
dc.contributor.authorKemer, Baris
dc.contributor.authorDemir, Ersin
dc.date.accessioned2024-05-25T11:19:19Z
dc.date.available2024-05-25T11:19:19Z
dc.date.issued2018
dc.departmentOkan Universityen_US
dc.department-temp[Kemer, Baris] Karadeniz Tech Univ, Dept Chem, Fac Sci, TR-61100 Trabzon, Turkey; [Demir, Ersin] Okan Univ, Dept Food Engn, Fac Engn, TR-34959 Istanbul, Turkeyen_US
dc.descriptionDemir, Ersin/0000-0001-9180-0609en_US
dc.description.abstractA novel solid state potentiometric pH electrode based on sulfated natural Fe3O4 silicone was fabricated. The optimum potentiometric performances such as Nernstian response, response time, selectivity, life-time and reproducibility of pH electrodes were investigated by using a computer-controlled potentiometric device. Moreover, the potentiometric performance of the solid state pH electrodes was studied with different mixtures sulfated natural Fe3O4, silicone and graphite powder. The best potentiometric behavior of proposed pH electrode was obtained with a composition of 20% (w/w) sulfated natural Fe3O4, 40% (w/w) graphite powder and 40% (w/w) silicone. The sub-Nernstian response for pH electrode was exhibited with a slope of 30.8 +/- 1.4mV/pH (r=0.9963) from pH 2 to pH 12. In addition, the dynamic response time was found as 10s in acidic medium and further the proposed pH electrode can be used for at least 1year without any significant slope of the pH-potential curve. The selectivity coefficient of pH electrode was interpreted according to fixed interference method in the presences of Na+, Li+, K+, NH4+, SO42, CH3COO and NO3 ions. The reproducibility of pH electrode was calculated in pH 4 and pH 6 phosphate buffers and it was found as 0.24 RSD (%) and 0.27 RSD (%) respectively. The proposed pH electrode was used to determine of pH in acidbases titration compared with glass pH electrode and is highly stable in corrosive systems including HF solution. Terminally, the pH value was successfully determined in some soft drinks and milk samples by proposed solid state pH electrode at 95% confidence level with satisfactory agreement compared with glass pH electrode.en_US
dc.identifier.citation3
dc.identifier.doi10.1007/s11694-018-9842-0
dc.identifier.endpage2262en_US
dc.identifier.issn2193-4126
dc.identifier.issn2193-4134
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-85049134676
dc.identifier.scopusqualityQ2
dc.identifier.startpage2256en_US
dc.identifier.urihttps://doi.org/10.1007/s11694-018-9842-0
dc.identifier.urihttps://hdl.handle.net/20.500.14517/403
dc.identifier.volume12en_US
dc.identifier.wosWOS:000452363700002
dc.identifier.wosqualityQ2
dc.language.isoen
dc.publisherSpringeren_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectpH ion selectivity electrodeen_US
dc.subjectpH determinationen_US
dc.subjectSolid state electrodeen_US
dc.subjectFood samplesen_US
dc.titleA novel potentiometric pH electrode based on sulfated natural Fe<sub>3</sub>O<sub>4</sub> and analytical application in food samplesen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files