Extended Kalman filter application for high-noise cancelation in control telemetry channels of oil electric submersible pump

dc.authorid Yilmaz, Murat/0000-0003-1584-1788
dc.authorid Hajiyev, Chingiz/0000-0003-4115-341X
dc.authorscopusid 16047167300
dc.authorscopusid 35614128600
dc.authorscopusid 24450647600
dc.authorscopusid 57034341400
dc.authorwosid Yilmaz, Murat/A-6867-2018
dc.authorwosid Hajiyev, Chingiz/ABA-9626-2020
dc.contributor.author Ali-Zade, Parviz
dc.contributor.author Hajiyev, Chingiz
dc.contributor.author Hajiyeva, Ulviyya
dc.contributor.author Yilmaz, Murat
dc.date.accessioned 2024-05-25T11:24:47Z
dc.date.available 2024-05-25T11:24:47Z
dc.date.issued 2013
dc.department Okan University en_US
dc.department-temp [Ali-Zade, Parviz] Okan Univ, Fac Engn & Architecture, TR-34959 Istanbul, Turkey; [Hajiyev, Chingiz] Istanbul Tech Univ, Fac Aeronaut & Astronaut, TR-34469 Istanbul, Turkey; [Hajiyeva, Ulviyya] Halic Univ, Dept Comp Engn, Istanbul, Turkey; [Yilmaz, Murat] Istanbul Tech Univ, Fac Elect & Elect, TR-34469 Istanbul, Turkey en_US
dc.description Yilmaz, Murat/0000-0003-1584-1788; Hajiyev, Chingiz/0000-0003-4115-341X en_US
dc.description.abstract Electro Submersible Pump (ESP) telemetry system allows getting information of different types of heavy electromagnetic noise: random, pulsing, harmonic etc. in the neighborhood They are pump unit's intake pressure, temperature and most importantly its insulation resistance for submersible motor stator coil reliability - for the successful exploitation of the oil complexes. The change from analog to digital communication techniques is going at a fast rate in almost all technical fields. But increasing disturbance levels with corrupted analog communication result in an increased noise level, but are often still "audible" or the control system is still reliable. With increasing disturbance levels, the analog signal will be audible, but will remain low. However beyond a certain disturbance level, the so called "digital cliff", the digital communication and the control stop abruptly. In this study, the extended Kalman filter (EKF) is designed and examined under severe noise conditions for the high-noise cancelation in control telemetry channels of oil ESP. The results approve a high performance of the developed EKF. (C) 2013 Elsevier B.V. All rights reserved. en_US
dc.identifier.citationcount 6
dc.identifier.doi 10.1016/j.petrol.2013.08.051
dc.identifier.endpage 118 en_US
dc.identifier.issn 0920-4105
dc.identifier.issn 1873-4715
dc.identifier.scopus 2-s2.0-84884865758
dc.identifier.scopusquality Q1
dc.identifier.startpage 109 en_US
dc.identifier.uri https://doi.org/10.1016/j.petrol.2013.08.051
dc.identifier.uri https://hdl.handle.net/20.500.14517/850
dc.identifier.volume 110 en_US
dc.identifier.wos WOS:000328176800012
dc.identifier.wosquality Q1
dc.language.iso en
dc.publisher Elsevier Science Bv en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.scopus.citedbyCount 6
dc.subject Kalman filter en_US
dc.subject oil industry en_US
dc.subject electric submersible pump en_US
dc.subject telemetry channels en_US
dc.subject noise en_US
dc.subject reliability en_US
dc.title Extended Kalman filter application for high-noise cancelation in control telemetry channels of oil electric submersible pump en_US
dc.type Article en_US
dc.wos.citedbyCount 6

Files