A modified endoscopic technique for the repair of isolated orbital floor fractures
dc.authorscopusid | 57216183479 | |
dc.authorscopusid | 36916526700 | |
dc.authorscopusid | 57204463391 | |
dc.contributor.author | Abdelazem,M.H. | |
dc.contributor.author | Erdogan,Ö. | |
dc.contributor.author | Awad,T.A. | |
dc.date.accessioned | 2024-05-25T12:33:13Z | |
dc.date.available | 2024-05-25T12:33:13Z | |
dc.date.issued | 2020 | |
dc.department | Okan University | en_US |
dc.department-temp | Abdelazem M.H., Department of Plastic Surgery, Cairo University Hospital, Cairo, Egypt; Erdogan Ö., Department of Oral and Maxillofacial Surgery, Okan University Hospital, Necmettin Erbakan Cd. No:2, Aydıntepe Mh, 34348, Tuzla, Istanbul, Turkey; Awad T.A., Tarek Ahmed Awad, MD, Department of General Surgery, Cairo University Hospital, Cairo, Egypt | en_US |
dc.description.abstract | Endoscopically assisted transantral approach has been used since more than 2 decades for the repair of orbital floor fractures. Its popularity has increased worldwide as it overcomes most of the disadvantages of traditional techniques such as visible scar, ectropion, entropion, eyelid shortening, and impaired visibility of the posterior edge of the defect. There are different endoscopic approaches for orbital floor repair. In this article, we present our endoscopic surgical technique to repair isolated orbital floor fractures using titanium mesh with a tight-fit fixation. The technique was used in 5 patients, and the minimum postoperative follow time was 3 months. Level of evidence: Level V, therapeutic study. © 2020, Springer-Verlag GmbH Germany, part of Springer Nature. | en_US |
dc.identifier.citation | 0 | |
dc.identifier.doi | 10.1007/s00238-020-01645-9 | |
dc.identifier.endpage | 494 | en_US |
dc.identifier.issn | 0930-343X | |
dc.identifier.issue | 4 | en_US |
dc.identifier.scopus | 2-s2.0-85082775246 | |
dc.identifier.scopusquality | Q3 | |
dc.identifier.startpage | 491 | en_US |
dc.identifier.uri | https://doi.org/10.1007/s00238-020-01645-9 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14517/2460 | |
dc.identifier.volume | 43 | en_US |
dc.language.iso | en | |
dc.publisher | Springer | en_US |
dc.relation.ispartof | European Journal of Plastic Surgery | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Blow-out fractures | en_US |
dc.subject | Endoscopically assisted surgery | en_US |
dc.subject | Minimally invasive surgery | en_US |
dc.subject | Transantral approach | en_US |
dc.title | A modified endoscopic technique for the repair of isolated orbital floor fractures | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |