Measurement of indoor radon concentration and annual effective dose estimation for a university campus in Istanbul

dc.authorid GÜNAY, Osman/0000-0003-0760-554X
dc.authorscopusid 57201976778
dc.authorscopusid 36482497000
dc.authorscopusid 56790177600
dc.authorwosid kulalı özdek, feride/JKJ-2912-2023
dc.authorwosid kulalı, feride/JKJ-2869-2023
dc.authorwosid GÜNAY, Osman/X-7344-2018
dc.contributor.author Gunay, Osman
dc.contributor.author Akozcan, Serpil
dc.contributor.author Kulali, Feride
dc.date.accessioned 2024-05-25T11:41:05Z
dc.date.available 2024-05-25T11:41:05Z
dc.date.issued 2019
dc.department Okan University en_US
dc.department-temp [Gunay, Osman] Istanbul Okan Univ, Vocat Sch Hlth Serv, TR-34969 Istanbul, Turkey; [Akozcan, Serpil] Kirklareli Univ, Fac Arts & Sci, Kirklareli, Turkey; [Kulali, Feride] Uskudar Univ, Vocat Sch Hlth Serv, Istanbul, Turkey en_US
dc.description GÜNAY, Osman/0000-0003-0760-554X en_US
dc.description.abstract Radiation is a natural part of the environment that people interact continuously, and radon is one of the most important sources because of its abundance and mobility. Due to gas form, radon can reach and accumulate in living places easily. Inhalation of radon and its progenies is an important risk factor for health hazards. Accurate measurement of radon levels is quite essential for the dose evaluation of radon exposure in buildings. In this study, radon activity measurements have been performed by using AlphaGUARD portable radon detector at several locations in Akfirat campus of Istanbul Okan University. Annual effective doses were calculated by using ICRP regulations for various exposure periods. en_US
dc.identifier.citationcount 10
dc.identifier.doi 10.1007/s12517-019-4344-x
dc.identifier.issn 1866-7511
dc.identifier.issn 1866-7538
dc.identifier.issue 5 en_US
dc.identifier.scopus 2-s2.0-85062303693
dc.identifier.uri https://doi.org/10.1007/s12517-019-4344-x
dc.identifier.uri https://hdl.handle.net/20.500.14517/1469
dc.identifier.volume 12 en_US
dc.identifier.wos WOS:000459981500005
dc.language.iso en
dc.publisher Springer Heidelberg en_US
dc.relation.ispartof 4th International Conference on Computational and Experimental Science and Engineering (ICCESEN) -- OCT 04-08, 2017 -- Antalya, TURKEY en_US
dc.relation.publicationcategory Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 19
dc.subject Radon en_US
dc.subject Indoor en_US
dc.subject Istanbul en_US
dc.title Measurement of indoor radon concentration and annual effective dose estimation for a university campus in Istanbul en_US
dc.type Conference Object en_US
dc.wos.citedbyCount 11

Files