A Novel all Solid-State Contact PVC-Membrane Beryllium-Selective Electrode Based on 4-Hydroxybenzo-15-Crown-5 Ether Ionophore

dc.authorid Demir, Ersin/0000-0001-9180-0609
dc.authorid isildak, ibrahim/0000-0001-9654-1386
dc.authorid Attar, Azade/0000-0001-6906-6989
dc.authorscopusid 6603596907
dc.authorscopusid 55755380000
dc.authorscopusid 55910480000
dc.authorscopusid 56470686700
dc.authorscopusid 35518926800
dc.authorwosid Demir, Ersin/V-6633-2019
dc.contributor.author Isildak, Ibrahim
dc.contributor.author Attar, Azade
dc.contributor.author Demir, Ersin
dc.contributor.author Kemer, Baris
dc.contributor.author Aboul-Enein, Hassan Y.
dc.date.accessioned 2024-05-25T11:19:13Z
dc.date.available 2024-05-25T11:19:13Z
dc.date.issued 2018
dc.department Okan University en_US
dc.department-temp [Isildak, Ibrahim; Attar, Azade] Yildiz Tech Univ, Fac Chem & Met Engn, Dept Bioengn, Davutpasa Campus, TR-34210 Istanbul, Turkey; [Demir, Ersin] Okan Univ, Vocat Sch Hlth Serv, Perfus Techn, TR-34959 Istanbul, Turkey; [Kemer, Baris] Karadeniz Tech Univ, Fac Sci, Dept Chem, Trabzon, Turkey; [Aboul-Enein, Hassan Y.] Natl Res Ctr, Pharmaceut & Med Chem Dept, Pharmaceut & Drug Ind Res Div, Giza 12622, Egypt en_US
dc.description Demir, Ersin/0000-0001-9180-0609; isildak, ibrahim/0000-0001-9654-1386; Attar, Azade/0000-0001-6906-6989 en_US
dc.description.abstract Aim: A novel all solid-state contact PVC-membrane beryllium-selective electrode based on 4-hydroxybenzo-15-crown-5 ether as an ionophore is described. Results: The best performance was obtained with a membrane composition of 4% ionophore, 67% dioctyl sebacate (DOS), 28% poly(vinyl chloride) (PVC), and 1% potassium tetrakis (p-chloro) phenylborate (KTClPB) (w/w). The all solid-state contact PVCmembrane beryllium-selective electrode together with an Ag/AgCl reference electrode exhibited sub-Nernstian response with a slope of 22 +/- 1 mV/decade to beryllium ions from 1.0x10(-6) to 1.0x10(-1) M, and resulted a considerably low detection limit of 6.2x10(-7). The electrode had a good performance in selectivity over a wide range of interfering cations tested. It showed a working pH range between 4.0-8.2 with fast response time (< 10 s) and a good reproducibility. Conclusion: The all solid-state contact PVC-membrane beryllium-selective electrode developed was successfully applied in potentiometric titration of Be2+ ions with EDTA. en_US
dc.identifier.citationcount 15
dc.identifier.doi 10.2174/1573411012666161014164546
dc.identifier.endpage 48 en_US
dc.identifier.issn 1573-4110
dc.identifier.issn 1875-6727
dc.identifier.issue 1 en_US
dc.identifier.scopus 2-s2.0-85041511680
dc.identifier.scopusquality Q2
dc.identifier.startpage 43 en_US
dc.identifier.uri https://doi.org/10.2174/1573411012666161014164546
dc.identifier.uri https://hdl.handle.net/20.500.14517/390
dc.identifier.volume 14 en_US
dc.identifier.wos WOS:000419551200007
dc.identifier.wosquality Q3
dc.language.iso en
dc.publisher Bentham Science Publ Ltd en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 16
dc.subject Beryllium-selective electrode en_US
dc.subject 4-hydroxybenzo-15-crown-5 ether en_US
dc.subject potentiometry en_US
dc.subject PVC membrane en_US
dc.subject ionophore en_US
dc.subject EDTA en_US
dc.title A Novel all Solid-State Contact PVC-Membrane Beryllium-Selective Electrode Based on 4-Hydroxybenzo-15-Crown-5 Ether Ionophore en_US
dc.type Article en_US
dc.wos.citedbyCount 15

Files