Fe<SUP>3+</SUP> - Ion Selective Electrode Developed as a Detector in Flow Injection Analysis

dc.authorid Demir, Ersin/0000-0001-9180-0609
dc.authorid isildak, ibrahim/0000-0001-9654-1386
dc.authorscopusid 55910480000
dc.authorscopusid 56470686700
dc.authorscopusid 6603596907
dc.authorscopusid 35518926800
dc.authorwosid Demir, Ersin/V-6633-2019
dc.contributor.author Demir, Ersin
dc.contributor.author Kemer, Baris
dc.contributor.author Isildak, Ibrahim
dc.contributor.author Aboul-Enein, Hassan Y.
dc.date.accessioned 2024-05-25T11:18:02Z
dc.date.available 2024-05-25T11:18:02Z
dc.date.issued 2015
dc.department Okan University en_US
dc.department-temp [Demir, Ersin] Okan Univ, Vocat Sch Hlth Serv, Perfus Tech, TR-34959 Istanbul, Turkey; [Kemer, Baris] Karadeniz Tech Univ, Fac Sci, Dept Chem, TR-61100 Trabzon, Turkey; [Isildak, Ibrahim] Yildiz Tech Univ, Fac Chem & Met Engn, Dept Bioengn, TR-34210 Istanbul, Turkey; [Aboul-Enein, Hassan Y.] Natl Res Ctr, Pharmaceut & Med Chem Dept, Pharmaceut & Drug Ind Res Div, Giza 12662, Egypt en_US
dc.description Demir, Ersin/0000-0001-9180-0609; isildak, ibrahim/0000-0001-9654-1386 en_US
dc.description.abstract A new polyvinyl chloride (PVC) membrane Fe3+ - ion selective electrode was constructed as a detector for the analysis Fe3+ using a home-made low-volume flow through cell. Optimum working conditions for the flow injection analysis (FIA) measurements were examined. In addition, under optimum conditions, potentiometric performance characteristics of the Fe3+ ion-selective electrode were investigated. Electrode had a linear response in the concentration range of 1.0 x 10(-3)-1.0 x 10(-6) M (R-2=0.9961, y=24.7+772.0). Reproducibility of the electrode responses was very satisfied. The potential of Fe3+ ion selective electrode was decreased intra and inter day 0.9 % and 3.7% respectively. The designed flow-through cell system as Fe3+ detector revealed sampling rates of approximately 50 injections per hour. The obtained results in FIA were in a good agreement with AAs results at % 95 confidence level for each syrups. en_US
dc.identifier.citationcount 3
dc.identifier.doi 10.2174/1573411011666150128193424
dc.identifier.endpage 108 en_US
dc.identifier.issn 1573-4110
dc.identifier.issn 1875-6727
dc.identifier.issue 2 en_US
dc.identifier.scopus 2-s2.0-84936746957
dc.identifier.scopusquality Q2
dc.identifier.startpage 104 en_US
dc.identifier.uri https://doi.org/10.2174/1573411011666150128193424
dc.identifier.uri https://hdl.handle.net/20.500.14517/282
dc.identifier.volume 11 en_US
dc.identifier.wos WOS:000350481300004
dc.identifier.wosquality Q3
dc.language.iso en
dc.publisher Bentham Science Publ Ltd en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 3
dc.subject Iron-selective electrode en_US
dc.subject determination en_US
dc.subject flow injection system en_US
dc.subject potentiometer en_US
dc.subject syrups analysis en_US
dc.title Fe<SUP>3+</SUP> - Ion Selective Electrode Developed as a Detector in Flow Injection Analysis en_US
dc.type Article en_US
dc.wos.citedbyCount 3

Files