How do Reused Glide Path Files Affect the Cyclic Fatigue Resistance?;

dc.authorid Arican, Burcin/0000-0001-5757-0571
dc.authorscopusid 56094357600
dc.authorscopusid 57204595215
dc.authorwosid Ates, Ayfer Atav/ABC-2676-2022
dc.contributor.author Arıcan,B.
dc.contributor.author Ateş,A.A.
dc.date.accessioned 2024-05-25T11:27:01Z
dc.date.available 2024-05-25T11:27:01Z
dc.date.issued 2021
dc.department Okan University en_US
dc.department-temp Arıcan B., İstanbul Okan University, Faculty of Dentistry, Department of Endodontics, Turkey; Ateş A.A., İstanbul Okan University, Faculty of Dentistry, Department of Endodontics, Turkey en_US
dc.description Arican, Burcin/0000-0001-5757-0571 en_US
dc.description.abstract The aim of this study was to compare the cyclic fatigue resistance (CFR) of PathFile (Dentsply Sirona, Ballaigues, Switzerland) and ScoutRace (FKG Dentaire, La Chaux-de-Fonds, Switzerland) glide path files which were either new or previously used. Forty PathFile (PF) 19/.02 and 40 ScoutRace (SR) 20/.02 instruments were used for this study. Half of the files in each group were used (PF-U and SR-U) in the 3D demo tooth models (FKG Dentaire, La Chaux-de-Fonds, Switzerland) for creating glide paths, while the other half was new (PF-N and SR-N) and directly subjected to the cyclic fatigue test. The new and used files (n=80) were rotated in the cyclic fatigue test device with an artificial stainless-steel canal (60° curvature, 5 mm radius 1.5 mm width and 3.0 mm depth) under the continuous irrigation with distilled water at 37°C until fracture occurred. Time to fracture was recorded and the Weibull reliability analysis was performed. Data were statistically analysed. Conformity to normal distribution was examined using the Shapiro-Wilk test. A paired two-sample t-test was used to compare the TTF values according to the time within the groups. The new instruments (PF-N and SR-N) showed better CFR than the used groups (PF-U and SR-U) (P<0.05). The TTF values of PF were statistically higher than SR in both new and used groups (P<0.05). The predicted time for %99 survival for the files was PF-N> SR-N>PF-U >SR-U. Reuse of both glide path instruments reduced the time to fracture and the cyclic fatigue resistance of the files. © 2021, Universidad de Costa Rica. All rights reserved. en_US
dc.identifier.citationcount 0
dc.identifier.doi 10.15517/IJDS.2021.47503
dc.identifier.endpage 106 en_US
dc.identifier.issn 1659-1046
dc.identifier.issue 3 en_US
dc.identifier.scopus 2-s2.0-85197168377
dc.identifier.scopusquality Q3
dc.identifier.startpage 98 en_US
dc.identifier.uri https://doi.org/10.15517/IJDS.2021.47503
dc.identifier.volume 23 en_US
dc.identifier.wos WOS:000691897600011
dc.language.iso en
dc.publisher Universidad de Costa Rica en_US
dc.relation.ispartof Odovtos - International Journal of Dental Sciences en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.scopus.citedbyCount 0
dc.subject Cyclic fatigue resistance en_US
dc.subject Demo model en_US
dc.subject Glide path en_US
dc.subject PathFile en_US
dc.subject Reuse en_US
dc.subject ScoutRace en_US
dc.title How do Reused Glide Path Files Affect the Cyclic Fatigue Resistance?; en_US
dc.title.alternative ¿Cómo afecta la reutilización de limas tipo glide path su resistencia a la fatiga cíclica? en_US
dc.type Article en_US
dc.wos.citedbyCount 0

Files