Measurement of Radiation Dose in Thyroid Scintigraphy

dc.authorid Demir, Mustafa/0000-0002-9813-1628
dc.authorid Gunay, Osman/0000-0003-0760-554X
dc.authorwosid Demir, Mustafa/E-2809-2019
dc.authorwosid Yarar, Onur/Gqb-0398-2022
dc.authorwosid Akkurt, Iskender/Agp-2700-2022
dc.authorwosid Sarihan, Mucize/Afr-1024-2022
dc.authorwosid Gunay, Osman/X-7344-2018
dc.contributor.author Gunay, O.
dc.contributor.author Sarihan, M.
dc.contributor.author Yarar, O.
dc.contributor.author Akkurt, I.
dc.contributor.author Demir, M.
dc.date.accessioned 2024-05-25T12:33:10Z
dc.date.available 2024-05-25T12:33:10Z
dc.date.issued 2020
dc.department Okan University en_US
dc.department-temp [Gunay, O.; Sarihan, M.; Yarar, O.] Stanbul Okan Univ, Vocat Sch Hlth Serv, Istanbul, Turkey; [Akkurt, I.] Suleyman Demirel Univ, Dept Phys, Fac Art & Sci, Isparta, Turkey; [Demir, M.] Istanbul Univ Cerrahpasa, Cerrahpasa Fac Med, Dept Nucl Med, Istanbul, Turkey en_US
dc.description Demir, Mustafa/0000-0002-9813-1628; Gunay, Osman/0000-0003-0760-554X en_US
dc.description.abstract Determination of radiation dose rate is very important for public health and medical workers because the nuclear radiation is hazardous for all. In this study, radiation dose rate was determined after radiopharmaceutical injection for thyroid scintigraphy. Measurements of the dose rate were made at 12 different points: 25, 50, 100, and 200 cm from the patient's head, chest and foot level. Moreover, measurements were made at different times with GM counter to determine the dose rate decay. The amount of radioactivity injected into patients varies between 151 MBq (4.1 Ci) and 192 MBq (5.2 Ci), with average value of 162 MBq (4.4 Ci). The radiation dose rate at 100 cm from the patient's chest level, after 9.16, 28.83 and 49.66 min of injection was calculated as 7.56, 6.35 and 4.73 mu Svh(-1), respectively. After Tc-99m injection, healthcare professionals must be 1 m away from the patient for radiation safety. It was also emphasized that the public should not be in proximity to the patient nearer than 1 m for 3 h after injection. en_US
dc.description.woscitationindex Science Citation Index Expanded - Conference Proceedings Citation Index - Science
dc.identifier.citationcount 34
dc.identifier.doi 10.12693/APhysPolA.137.569
dc.identifier.endpage 573 en_US
dc.identifier.issn 0587-4246
dc.identifier.issn 1898-794X
dc.identifier.issue 4 en_US
dc.identifier.scopus 2-s2.0-85090774730
dc.identifier.scopusquality Q3
dc.identifier.startpage 569 en_US
dc.identifier.uri https://doi.org/10.12693/APhysPolA.137.569
dc.identifier.volume 137 en_US
dc.identifier.wos WOS:000537521100033
dc.identifier.wosquality Q4
dc.institutionauthor Sarihan M.
dc.institutionauthor Sarıhan, Mucize
dc.institutionauthor Yarar, Onur
dc.language.iso en
dc.language.iso en en_US
dc.publisher Polish Acad Sciences inst Physics en_US
dc.relation.ispartof 6th International Conference on Computational and Experimental Science and Engineering (ICCESEN) -- OCT 23-27, 2019 -- Antalya, TURKEY en_US
dc.relation.publicationcategory Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.scopus.citedbyCount 37
dc.title Measurement of Radiation Dose in Thyroid Scintigraphy en_US
dc.type Conference Object en_US

Files