A Novel all Solid-State Contact PVC-Membrane Beryllium-Selective Electrode Based on 4-Hydroxybenzo-15-Crown-5 Ether Ionophore

dc.authoridDemir, Ersin/0000-0001-9180-0609
dc.authoridisildak, ibrahim/0000-0001-9654-1386
dc.authoridAttar, Azade/0000-0001-6906-6989
dc.authorscopusid6603596907
dc.authorscopusid55755380000
dc.authorscopusid55910480000
dc.authorscopusid56470686700
dc.authorscopusid35518926800
dc.authorwosidDemir, Ersin/V-6633-2019
dc.contributor.authorIsildak, Ibrahim
dc.contributor.authorAttar, Azade
dc.contributor.authorDemir, Ersin
dc.contributor.authorKemer, Baris
dc.contributor.authorAboul-Enein, Hassan Y.
dc.date.accessioned2024-05-25T11:19:13Z
dc.date.available2024-05-25T11:19:13Z
dc.date.issued2018
dc.departmentOkan Universityen_US
dc.department-temp[Isildak, Ibrahim; Attar, Azade] Yildiz Tech Univ, Fac Chem & Met Engn, Dept Bioengn, Davutpasa Campus, TR-34210 Istanbul, Turkey; [Demir, Ersin] Okan Univ, Vocat Sch Hlth Serv, Perfus Techn, TR-34959 Istanbul, Turkey; [Kemer, Baris] Karadeniz Tech Univ, Fac Sci, Dept Chem, Trabzon, Turkey; [Aboul-Enein, Hassan Y.] Natl Res Ctr, Pharmaceut & Med Chem Dept, Pharmaceut & Drug Ind Res Div, Giza 12622, Egypten_US
dc.descriptionDemir, Ersin/0000-0001-9180-0609; isildak, ibrahim/0000-0001-9654-1386; Attar, Azade/0000-0001-6906-6989en_US
dc.description.abstractAim: A novel all solid-state contact PVC-membrane beryllium-selective electrode based on 4-hydroxybenzo-15-crown-5 ether as an ionophore is described. Results: The best performance was obtained with a membrane composition of 4% ionophore, 67% dioctyl sebacate (DOS), 28% poly(vinyl chloride) (PVC), and 1% potassium tetrakis (p-chloro) phenylborate (KTClPB) (w/w). The all solid-state contact PVCmembrane beryllium-selective electrode together with an Ag/AgCl reference electrode exhibited sub-Nernstian response with a slope of 22 +/- 1 mV/decade to beryllium ions from 1.0x10(-6) to 1.0x10(-1) M, and resulted a considerably low detection limit of 6.2x10(-7). The electrode had a good performance in selectivity over a wide range of interfering cations tested. It showed a working pH range between 4.0-8.2 with fast response time (< 10 s) and a good reproducibility. Conclusion: The all solid-state contact PVC-membrane beryllium-selective electrode developed was successfully applied in potentiometric titration of Be2+ ions with EDTA.en_US
dc.identifier.citation15
dc.identifier.doi10.2174/1573411012666161014164546
dc.identifier.endpage48en_US
dc.identifier.issn1573-4110
dc.identifier.issn1875-6727
dc.identifier.issue1en_US
dc.identifier.scopus2-s2.0-85041511680
dc.identifier.scopusqualityQ2
dc.identifier.startpage43en_US
dc.identifier.urihttps://doi.org/10.2174/1573411012666161014164546
dc.identifier.urihttps://hdl.handle.net/20.500.14517/390
dc.identifier.volume14en_US
dc.identifier.wosWOS:000419551200007
dc.identifier.wosqualityQ3
dc.language.isoen
dc.publisherBentham Science Publ Ltden_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBeryllium-selective electrodeen_US
dc.subject4-hydroxybenzo-15-crown-5 etheren_US
dc.subjectpotentiometryen_US
dc.subjectPVC membraneen_US
dc.subjectionophoreen_US
dc.subjectEDTAen_US
dc.titleA Novel all Solid-State Contact PVC-Membrane Beryllium-Selective Electrode Based on 4-Hydroxybenzo-15-Crown-5 Ether Ionophoreen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files