A Novel all Solid-State Contact PVC-Membrane Beryllium-Selective Electrode Based on 4-Hydroxybenzo-15-Crown-5 Ether Ionophore
dc.authorid | Demir, Ersin/0000-0001-9180-0609 | |
dc.authorid | isildak, ibrahim/0000-0001-9654-1386 | |
dc.authorid | Attar, Azade/0000-0001-6906-6989 | |
dc.authorscopusid | 6603596907 | |
dc.authorscopusid | 55755380000 | |
dc.authorscopusid | 55910480000 | |
dc.authorscopusid | 56470686700 | |
dc.authorscopusid | 35518926800 | |
dc.authorwosid | Demir, Ersin/V-6633-2019 | |
dc.contributor.author | Isildak, Ibrahim | |
dc.contributor.author | Attar, Azade | |
dc.contributor.author | Demir, Ersin | |
dc.contributor.author | Kemer, Baris | |
dc.contributor.author | Aboul-Enein, Hassan Y. | |
dc.date.accessioned | 2024-05-25T11:19:13Z | |
dc.date.available | 2024-05-25T11:19:13Z | |
dc.date.issued | 2018 | |
dc.department | Okan University | en_US |
dc.department-temp | [Isildak, Ibrahim; Attar, Azade] Yildiz Tech Univ, Fac Chem & Met Engn, Dept Bioengn, Davutpasa Campus, TR-34210 Istanbul, Turkey; [Demir, Ersin] Okan Univ, Vocat Sch Hlth Serv, Perfus Techn, TR-34959 Istanbul, Turkey; [Kemer, Baris] Karadeniz Tech Univ, Fac Sci, Dept Chem, Trabzon, Turkey; [Aboul-Enein, Hassan Y.] Natl Res Ctr, Pharmaceut & Med Chem Dept, Pharmaceut & Drug Ind Res Div, Giza 12622, Egypt | en_US |
dc.description | Demir, Ersin/0000-0001-9180-0609; isildak, ibrahim/0000-0001-9654-1386; Attar, Azade/0000-0001-6906-6989 | en_US |
dc.description.abstract | Aim: A novel all solid-state contact PVC-membrane beryllium-selective electrode based on 4-hydroxybenzo-15-crown-5 ether as an ionophore is described. Results: The best performance was obtained with a membrane composition of 4% ionophore, 67% dioctyl sebacate (DOS), 28% poly(vinyl chloride) (PVC), and 1% potassium tetrakis (p-chloro) phenylborate (KTClPB) (w/w). The all solid-state contact PVCmembrane beryllium-selective electrode together with an Ag/AgCl reference electrode exhibited sub-Nernstian response with a slope of 22 +/- 1 mV/decade to beryllium ions from 1.0x10(-6) to 1.0x10(-1) M, and resulted a considerably low detection limit of 6.2x10(-7). The electrode had a good performance in selectivity over a wide range of interfering cations tested. It showed a working pH range between 4.0-8.2 with fast response time (< 10 s) and a good reproducibility. Conclusion: The all solid-state contact PVC-membrane beryllium-selective electrode developed was successfully applied in potentiometric titration of Be2+ ions with EDTA. | en_US |
dc.identifier.citation | 15 | |
dc.identifier.doi | 10.2174/1573411012666161014164546 | |
dc.identifier.endpage | 48 | en_US |
dc.identifier.issn | 1573-4110 | |
dc.identifier.issn | 1875-6727 | |
dc.identifier.issue | 1 | en_US |
dc.identifier.scopus | 2-s2.0-85041511680 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 43 | en_US |
dc.identifier.uri | https://doi.org/10.2174/1573411012666161014164546 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14517/390 | |
dc.identifier.volume | 14 | en_US |
dc.identifier.wos | WOS:000419551200007 | |
dc.identifier.wosquality | Q3 | |
dc.language.iso | en | |
dc.publisher | Bentham Science Publ Ltd | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Beryllium-selective electrode | en_US |
dc.subject | 4-hydroxybenzo-15-crown-5 ether | en_US |
dc.subject | potentiometry | en_US |
dc.subject | PVC membrane | en_US |
dc.subject | ionophore | en_US |
dc.subject | EDTA | en_US |
dc.title | A Novel all Solid-State Contact PVC-Membrane Beryllium-Selective Electrode Based on 4-Hydroxybenzo-15-Crown-5 Ether Ionophore | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |