Evaluation of strain distribution on an edentulous mandible generated by cobalt-chromium metal alloy fixed complete dentures fabricated with different techniques: An in vitro study

dc.authorid Bozdag, Ergun/0000-0001-7412-1129
dc.authorid SUNBULOGLU, Emin/0000-0001-9930-4618
dc.authorid taşın, simge/0000-0002-0483-2520
dc.authorid , Isil/0000-0002-3862-5781
dc.authorscopusid 57205888500
dc.authorscopusid 56015932100
dc.authorscopusid 8628408800
dc.authorscopusid 8255630900
dc.authorscopusid 6603721071
dc.authorwosid Usumez, Aslihan/Z-4568-2019
dc.authorwosid Taşın, Simge/AAW-9341-2021
dc.authorwosid Bozdag, Ergun/ABA-9202-2020
dc.authorwosid SUNBULOGLU, Emin/ABB-3177-2020
dc.authorwosid taşın, simge/AAW-6948-2021
dc.contributor.author Tasin, Simge
dc.contributor.author Turp, Isil
dc.contributor.author Bozdag, Ergun
dc.contributor.author Sunbuloglu, Emin
dc.contributor.author Usumez, Aslihan
dc.date.accessioned 2024-05-25T11:41:48Z
dc.date.available 2024-05-25T11:41:48Z
dc.date.issued 2019
dc.department Okan University en_US
dc.department-temp [Tasin, Simge] Istanbul Okan Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey; [Turp, Isil] Bezmialem Vakif Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey; [Bozdag, Ergun; Sunbuloglu, Emin] Istanbul Tech Univ, Dept Mech Engn, Istanbul, Turkey; [Usumez, Aslihan] Dentalplus Implant Clin, Istanbul, Turkey en_US
dc.description Bozdag, Ergun/0000-0001-7412-1129; SUNBULOGLU, Emin/0000-0001-9930-4618; taşın, simge/0000-0002-0483-2520; , Isil/0000-0002-3862-5781 en_US
dc.description.abstract Statement of problem. Fixed complete dentures (FCDs) have been used in the treatment of completely edentulous patients for over 40 years. However, few reports have investigated misfit values and strain distribution in the context of FCDs fabricated with new technologies. Purpose. The purpose of this in vitro study was to evaluate misfit values and strain distribution in FCDs and their relation to the fabrication technique of the cobalt-chromium (Co-Cr) metal framework. Material and methods. Four implants were placed in the interforaminal region of a mandibular cast at the bone level. The Co-Cr metal alloy frameworks were fabricated using the following techniques: computer-aided design and computer-aided manufacturing (CAD-CAM), milling from hard blocks, CAD-CAM milling from soft blocks, and direct metal laser sintering (DMLS). The superstructures of equal sizes with acrylic resin bases and acrylic resin denture teeth were fabricated on the Co-Cr metal alloy framework, and a digital microscope was then used to measure the misfit between the abutments and the implants. The stress formed after the application of torque was measured with a strain-gauge stress analysis technique. Data were statistically analyzed using 1-way ANOVA and the Tukey Honestly Significant Difference test (alpha=.05). The correlation between the misfit and the strain values was evaluated with the Pearson Correlation test (alpha=.001). Results. The lowest mean misfit values (99 +/- 17 mu m) were observed in the hard block group (P<.05) and the highest in the DMLS group (139 +/- 29 mu m). A statistically significant positive relationship was found between the misfit and the stress distribution after torque application (P<.05). Moreover, the lowest misfit group, hard blocks, had the lowest mean strain values (81.1 +/- 54 MPa) after torque application. Conclusions. Within the limitations of this in vitro study, the fabrication technique used for Co-Cr metal alloy frameworks appears to influence the passive fit significantly (P<.05). The hard-block technique was found to be the most precise fabrication technique for Co-Cr metal alloy frameworks. A significant relationship was observed between the amount/distribution of misfit and the strain on the FCD (P<.05). en_US
dc.description.sponsorship Bezmialem Vakif University, Istanbul, Turkey [9.2015/9] en_US
dc.description.sponsorship This study was supported by grant no. 9.2015/9 from the Bezmialem Vakif University, Istanbul, Turkey, Research Foundation. en_US
dc.identifier.citationcount 16
dc.identifier.doi 10.1016/j.prosdent.2018.10.034
dc.identifier.endpage 53 en_US
dc.identifier.issn 0022-3913
dc.identifier.issn 1097-6841
dc.identifier.issue 1 en_US
dc.identifier.pmid 30782458
dc.identifier.scopus 2-s2.0-85061546209
dc.identifier.scopusquality Q1
dc.identifier.startpage 47 en_US
dc.identifier.uri https://doi.org/10.1016/j.prosdent.2018.10.034
dc.identifier.uri https://hdl.handle.net/20.500.14517/1552
dc.identifier.volume 122 en_US
dc.identifier.wos WOS:000472887300009
dc.identifier.wosquality Q1
dc.language.iso en
dc.publisher Mosby-elsevier en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 18
dc.subject [No Keyword Available] en_US
dc.title Evaluation of strain distribution on an edentulous mandible generated by cobalt-chromium metal alloy fixed complete dentures fabricated with different techniques: An in vitro study en_US
dc.type Article en_US
dc.wos.citedbyCount 16

Files