Evaluation of strain distribution on an edentulous mandible generated by cobalt-chromium metal alloy fixed complete dentures fabricated with different techniques: An in vitro study

dc.authoridBozdag, Ergun/0000-0001-7412-1129
dc.authoridSUNBULOGLU, Emin/0000-0001-9930-4618
dc.authoridtaşın, simge/0000-0002-0483-2520
dc.authorid, Isil/0000-0002-3862-5781
dc.authorscopusid57205888500
dc.authorscopusid56015932100
dc.authorscopusid8628408800
dc.authorscopusid8255630900
dc.authorscopusid6603721071
dc.authorwosidUsumez, Aslihan/Z-4568-2019
dc.authorwosidTaşın, Simge/AAW-9341-2021
dc.authorwosidBozdag, Ergun/ABA-9202-2020
dc.authorwosidSUNBULOGLU, Emin/ABB-3177-2020
dc.authorwosidtaşın, simge/AAW-6948-2021
dc.contributor.authorTasin, Simge
dc.contributor.authorTurp, Isil
dc.contributor.authorBozdag, Ergun
dc.contributor.authorSunbuloglu, Emin
dc.contributor.authorUsumez, Aslihan
dc.date.accessioned2024-05-25T11:41:48Z
dc.date.available2024-05-25T11:41:48Z
dc.date.issued2019
dc.departmentOkan Universityen_US
dc.department-temp[Tasin, Simge] Istanbul Okan Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey; [Turp, Isil] Bezmialem Vakif Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey; [Bozdag, Ergun; Sunbuloglu, Emin] Istanbul Tech Univ, Dept Mech Engn, Istanbul, Turkey; [Usumez, Aslihan] Dentalplus Implant Clin, Istanbul, Turkeyen_US
dc.descriptionBozdag, Ergun/0000-0001-7412-1129; SUNBULOGLU, Emin/0000-0001-9930-4618; taşın, simge/0000-0002-0483-2520; , Isil/0000-0002-3862-5781en_US
dc.description.abstractStatement of problem. Fixed complete dentures (FCDs) have been used in the treatment of completely edentulous patients for over 40 years. However, few reports have investigated misfit values and strain distribution in the context of FCDs fabricated with new technologies. Purpose. The purpose of this in vitro study was to evaluate misfit values and strain distribution in FCDs and their relation to the fabrication technique of the cobalt-chromium (Co-Cr) metal framework. Material and methods. Four implants were placed in the interforaminal region of a mandibular cast at the bone level. The Co-Cr metal alloy frameworks were fabricated using the following techniques: computer-aided design and computer-aided manufacturing (CAD-CAM), milling from hard blocks, CAD-CAM milling from soft blocks, and direct metal laser sintering (DMLS). The superstructures of equal sizes with acrylic resin bases and acrylic resin denture teeth were fabricated on the Co-Cr metal alloy framework, and a digital microscope was then used to measure the misfit between the abutments and the implants. The stress formed after the application of torque was measured with a strain-gauge stress analysis technique. Data were statistically analyzed using 1-way ANOVA and the Tukey Honestly Significant Difference test (alpha=.05). The correlation between the misfit and the strain values was evaluated with the Pearson Correlation test (alpha=.001). Results. The lowest mean misfit values (99 +/- 17 mu m) were observed in the hard block group (P<.05) and the highest in the DMLS group (139 +/- 29 mu m). A statistically significant positive relationship was found between the misfit and the stress distribution after torque application (P<.05). Moreover, the lowest misfit group, hard blocks, had the lowest mean strain values (81.1 +/- 54 MPa) after torque application. Conclusions. Within the limitations of this in vitro study, the fabrication technique used for Co-Cr metal alloy frameworks appears to influence the passive fit significantly (P<.05). The hard-block technique was found to be the most precise fabrication technique for Co-Cr metal alloy frameworks. A significant relationship was observed between the amount/distribution of misfit and the strain on the FCD (P<.05).en_US
dc.description.sponsorshipBezmialem Vakif University, Istanbul, Turkey [9.2015/9]en_US
dc.description.sponsorshipThis study was supported by grant no. 9.2015/9 from the Bezmialem Vakif University, Istanbul, Turkey, Research Foundation.en_US
dc.identifier.citation16
dc.identifier.doi10.1016/j.prosdent.2018.10.034
dc.identifier.endpage53en_US
dc.identifier.issn0022-3913
dc.identifier.issn1097-6841
dc.identifier.issue1en_US
dc.identifier.pmid30782458
dc.identifier.scopus2-s2.0-85061546209
dc.identifier.scopusqualityQ1
dc.identifier.startpage47en_US
dc.identifier.urihttps://doi.org/10.1016/j.prosdent.2018.10.034
dc.identifier.urihttps://hdl.handle.net/20.500.14517/1552
dc.identifier.volume122en_US
dc.identifier.wosWOS:000472887300009
dc.identifier.wosqualityQ1
dc.language.isoen
dc.publisherMosby-elsevieren_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subject[No Keyword Available]en_US
dc.titleEvaluation of strain distribution on an edentulous mandible generated by cobalt-chromium metal alloy fixed complete dentures fabricated with different techniques: An in vitro studyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files