Effect of Scanner Type and Scan Body Location on the Accuracy of Mandibular Complete-Arch Digital Implant Scans: An In Vitro Study

dc.authoridYilmaz, Hakan/0000-0002-9564-6212
dc.authoridCakmak, Gulce/0000-0003-1751-9207
dc.authorscopusid57217863941
dc.authorscopusid57210447211
dc.authorscopusid57193734310
dc.authorscopusid6505629724
dc.authorscopusid35583824600
dc.authorwosidCakmak, Gulce/GRE-6472-2022
dc.authorwosidÇAKMAK, GONCA/C-6464-2018
dc.authorwosidYILMAZ, HAKAN/JVO-9077-2024
dc.authorwosidYilmaz, Hakan/U-1749-2018
dc.contributor.authorCakmak, Gulce
dc.contributor.authorYilmaz, Hakan
dc.contributor.authorSantos, Alejandro Trevino
dc.contributor.authorKokat, Ali Murat
dc.contributor.authorYilmaz, Burak
dc.date.accessioned2024-05-25T11:26:35Z
dc.date.available2024-05-25T11:26:35Z
dc.date.issued2022
dc.departmentOkan Universityen_US
dc.department-temp[Cakmak, Gulce] Univ Bern, Buser Fdn Scholar Implant Dent, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland; [Yilmaz, Burak] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3010 Bern, Switzerland; [Yilmaz, Hakan] Yeditepe Univ, Fac Dent, Dept Orthodont, Istanbul, Turkey; [Santos, Alejandro Trevino] Univ Nacl Autonoma Mexico, Fac Dent, Postdoctoral & Res Div, Mexico City, DF, Mexico; [Kokat, Ali Murat] Istanbul Okan Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey; [Yilmaz, Burak] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland; [Yilmaz, Burak] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH 43210 USAen_US
dc.descriptionYilmaz, Hakan/0000-0002-9564-6212; Cakmak, Gulce/0000-0003-1751-9207en_US
dc.description.abstractPurpose To compare the accuracy (trueness and precision) of scans of a newly introduced intraoral scanner (IOS) (Virtuo Vivo) and a widely used IOS (Trios 3) to a laboratory scanner (LBS) (Cares 7 SERIES) for 6 implants placed in an edentulous mandible, and to investigate the effect of scan body location on trueness. Material and methods Scanbodies were tightened on 6 implants placed in an edentulous polymethylmethacrylate mandibular model. An industrial scanner was utilized to generate a master reference model STL file. Three different scanners were used to scan the model (2 IOSs and 1 LBS), and the scans (n = 10) were exported into STL files. Best-fitting algorithm was used to superimpose test scans over the MRM-STL (nominal). ANOVA and Tukey HSD tests were performed to analyze the data (alpha = 0.05). Results The distance deviations in Car7-LBS scans were the highest (p < 0.001), whereas those in Tri-IOS scans were the lowest (p < 0.001). Vir-IOS had lower angular deviations than those of Tri-IOS (p = 0.031). In Vir-IOS scans, SB5 had higher distance deviations than SB2 (p = 0.029) and SB3 (p = 0.044). In Car7-LBS scans, SB1 had higher distance deviations than SB3 (p = 0.015) and SB5 (p = 0.005). In Tri-IOS scans, SB1 had higher mean distance deviations than SB2 and SB5 (p = 0.005). Vir-IOS had lower precision than Car7-LBS (distance deviation data) (p = 0.01). No difference was found among scanners for the precision of angular deviation data (p = 0.840). Conclusion When trueness and precision were considered, distance and angular deviations depended on the scanner type. None of the scanners outperformed others in accuracy considering all distance and angular deviations. Scan body location affected only the trueness (distance deviations).en_US
dc.description.sponsorshipUniversitat Bernen_US
dc.description.sponsorshipOpen access funding provided by Universitat Bern.en_US
dc.identifier.citation9
dc.identifier.doi10.1111/jopr.13418
dc.identifier.endpage426en_US
dc.identifier.issn1059-941X
dc.identifier.issn1532-849X
dc.identifier.issue5en_US
dc.identifier.pmid34453466
dc.identifier.scopus2-s2.0-85115254864
dc.identifier.scopusqualityQ1
dc.identifier.startpage419en_US
dc.identifier.urihttps://doi.org/10.1111/jopr.13418
dc.identifier.urihttps://hdl.handle.net/20.500.14517/994
dc.identifier.volume31en_US
dc.identifier.wosWOS:000697530000001
dc.identifier.wosqualityQ1
dc.language.isoen
dc.publisherWileyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAccuracyen_US
dc.subjecttruenessen_US
dc.subjectprecisionen_US
dc.subjectmandibleen_US
dc.subjectimplanten_US
dc.subjectintraoral scanneren_US
dc.titleEffect of Scanner Type and Scan Body Location on the Accuracy of Mandibular Complete-Arch Digital Implant Scans: An In Vitro Studyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files