Repair of residual aortic dissections with frozen elephant trunk technique

dc.authoridantal, arzu/0000-0002-3410-2879
dc.authoridCekmecelioglu, Davut/0000-0003-1946-326X
dc.authoridAkbuut, Mustafa/0000-0002-6582-6546
dc.authorwosidtaş, serpil/AAA-5989-2021
dc.authorwosidantal, arzu/AAL-7422-2020
dc.authorwosidAkbulut, Mustafa/C-5259-2015
dc.authorwosidCekmecelioglu, Davut/J-6056-2019
dc.authorwosidCekmecelioglu, Davut/GQI-4542-2022
dc.authorwosidAkbuut, Mustafa/HPF-6240-2023
dc.contributor.authorAkbulut, Mustafa
dc.contributor.authorAk, Adnan
dc.contributor.authorTas, Serpil
dc.contributor.authorArslan, Ozgur
dc.contributor.authorAntal, Arzu
dc.contributor.authorCekmecelioglu, Davut
dc.contributor.authorTuncer, Altug
dc.date.accessioned2024-05-25T11:40:19Z
dc.date.available2024-05-25T11:40:19Z
dc.date.issued2020
dc.departmentOkan Universityen_US
dc.department-temp[Akbulut, Mustafa; Ak, Adnan; Tas, Serpil; Arslan, Ozgur; Antal, Arzu; Cekmecelioglu, Davut; Sismanoglu, Mesut; Tuncer, Altug] Kartal Kosuyolu Yuksek Ihtisas Training & Res Hos, Istanbul, Turkey; [Akbulut, Mustafa; Ak, Adnan; Tas, Serpil; Arslan, Ozgur; Antal, Arzu; Sismanoglu, Mesut] Kartal Kosuyolu Yuksek Ihtisas Training & Res Hos, Dept Cardiovasc Surg, Istanbul, Turkey; [Cekmecelioglu, Davut] Baylor Coll Med, Div Cardiothorac Surg, Houston, TX 77030 USA; [Tuncer, Altug] Istanbul Okan Univ Hosp, Dept Cardiovasc Surg, Istanbul, Turkeyen_US
dc.descriptionantal, arzu/0000-0002-3410-2879; Cekmecelioglu, Davut/0000-0003-1946-326X; Akbuut, Mustafa/0000-0002-6582-6546en_US
dc.description.abstractBackground: In this study, we present our mid-term results of reoperation with the frozen elephant trunk procedure due to patent false lumen-related complications in patients previously undergoing supracoronary aortic repair for acute type A aortic dissection. Methods: Between January 2013 and September 2018, a total of 23 patients (17 males, 6 females; mean age 51.5 +/- 9.7 years; range, 30 to 67 years) who underwent ascending aortic replacement due to type A aortic dissection and, later, frozen elephant trunk procedure for residual distal dissection were included. For diagnostic purposes and follow-up, computed tomography angiography was performed in all patients, and both re-entry and aortic diameters were evaluated. Echocardiography was used to evaluate cardiac function and valve pathologies. Results: The Ishimaru zone 0 (n=11, 47.8%), Ishimaru zone 1 (n=1, 4.3%), Ishimaru zone 2 (n=4, 17.4%), and Ishimaru zone 3 (n=7, 30.4%) were used for frozen elephant trunk stent graft fixation. The mean duration of cardiopulmonary bypass and antegrade selective cerebral perfusion was 223.9 +/- 71.2 min and 88.9 +/- 60.3 min, respectively. In-hospital mortality was 13%, while there was one (4.3%) aortic-related death and four (17.4%) re-interventions during follow-up. Conclusion: Early repair should be considered in the presence of persistent dissections due to alarmingly high mortality rates of reoperations. Reoperation with the frozen elephant trunk procedure has acceptable results and the decision of the procedure to be performed should be based on preoperative risk factors of the patient.en_US
dc.identifier.citation0
dc.identifier.doi10.5606/tgkdc.dergisi.2020.19273
dc.identifier.endpage425en_US
dc.identifier.issn1301-5680
dc.identifier.issue3en_US
dc.identifier.pmid32953203
dc.identifier.scopusqualityQ4
dc.identifier.startpage419en_US
dc.identifier.trdizinid372453
dc.identifier.urihttps://doi.org/10.5606/tgkdc.dergisi.2020.19273
dc.identifier.urihttps://hdl.handle.net/20.500.14517/1428
dc.identifier.volume28en_US
dc.identifier.wosWOS:000558257400002
dc.identifier.wosqualityQ4
dc.language.isoen
dc.publisherBaycinar Medical Publ-baycinar Tibbi Yayinciliken_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAortic dissectionen_US
dc.subjectfrozen elephant trunken_US
dc.subjecthybrid procedureen_US
dc.subjectreoperationen_US
dc.titleRepair of residual aortic dissections with frozen elephant trunk techniqueen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files