Screw stability of CAD-CAM titanium and zirconia abutments on different implants: An in vitro study

dc.authoridbatak, burcu/0000-0001-5363-5067
dc.authoridJohnston, William Michael/0000-0002-4977-6569
dc.authoridCakmak, Gulce/0000-0003-1751-9207
dc.authorscopusid35583824600
dc.authorscopusid57217863941
dc.authorscopusid57211015010
dc.authorscopusid34769682900
dc.authorwosidbatak, burcu/HFZ-9892-2022
dc.authorwosidCakmak, Gulce/GRE-6472-2022
dc.authorwosidÇAKMAK, GONCA/C-6464-2018
dc.authorwosidJohnston, William Michael/E-8458-2012
dc.contributor.authorYilmaz, Burak
dc.contributor.authorCakmak, Gulce
dc.contributor.authorBatak, Burcu
dc.contributor.authorJohnston, William M.
dc.date.accessioned2024-05-25T11:42:38Z
dc.date.available2024-05-25T11:42:38Z
dc.date.issued2021
dc.departmentOkan Universityen_US
dc.department-temp[Yilmaz, Burak] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland; [Yilmaz, Burak] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland; [Yilmaz, Burak; Johnston, William M.] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH 43210 USA; [Cakmak, Gulce] Istanbul Okan Univ, Dept Prosthodont, Fac Dent, Istanbul, Turkey; [Batak, Burcu] Ankara Univ, Fac Dent, Dept Prosthodont, Ankara, Turkeyen_US
dc.descriptionbatak, burcu/0000-0001-5363-5067; Johnston, William Michael/0000-0002-4977-6569; Cakmak, Gulce/0000-0003-1751-9207en_US
dc.description.abstractBackground Limited information is available regarding the removal torque values (RTVs) of screws of different abutment materials when used with different implants. Purpose To evaluate the effect of implant type and abutment material (zirconia; Zir and titanium; Ti) on the RTVs of abutment screws after cyclic loading. Materials and methods Internal conical connection implants (CC, OsseoSpeed TX) and modified internal conical connection implants (MCC, OsseoSpeed EV) (n = 10) were clamped in resin dies. Zir and Ti (N = 20) custom abutments were tightened to implants (20 Ncm for CC and 25 Ncm for MCC) as specified by their manufacturers. The abutments were cyclically loaded by using a sequentially increased loading protocol; 2-million cycles under 100 N, 3-million cycles under 200 N, and 2-million cycles under 300 N loads with 2 Hz. After 7 million cycles, RTVs (Ncm) were measured by using a torque gauge. The data were analyzed with ANOVA by using the restricted maximum likelihood estimation method. Tukey-Kramer adjustment was used for any significant interaction of implant-abutment pairs (alpha = 0.05). Results Two CC implants, 1 with Ti and 1 with Zir abutment, fractured during cyclic loading (under 300 N loads within the 6th and 7th million cycles) and discarded for statistical analysis. Only implant type had a significant effect on RTVs (p <0.001). Screws of Ti abutments on MCC implants had significantly higher RTVs than the screws of Ti (p = 0.003) and Zir (p = 0.005) abutments on CC implants. Conclusions Implant type affected the RTVs, however, the RTVs were higher than the initial torque values for all groups. Screws of Ti abutments on implant, which required greater initial torque values had higher RTVs than the screws of Ti and Zir abutments on the implant that required smaller initial torque values. RTVs were similar for Zir and Ti abutment screws within each implant type.en_US
dc.description.sponsorshipDentsply Implants Investigator Initiated Studies [I-AA-14-055]en_US
dc.description.sponsorshipDentsply Implants Investigator Initiated Studies, Grant/Award Number: I-AA-14-055en_US
dc.identifier.citation4
dc.identifier.doi10.1111/cid.13001
dc.identifier.endpage379en_US
dc.identifier.issn1523-0899
dc.identifier.issn1708-8208
dc.identifier.issue3en_US
dc.identifier.pmid33938119
dc.identifier.scopus2-s2.0-85104995871
dc.identifier.scopusqualityQ1
dc.identifier.startpage373en_US
dc.identifier.urihttps://doi.org/10.1111/cid.13001
dc.identifier.urihttps://hdl.handle.net/20.500.14517/1624
dc.identifier.volume23en_US
dc.identifier.wosWOS:000646075200001
dc.identifier.wosqualityQ1
dc.language.isoen
dc.publisherWileyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectabutmenten_US
dc.subjectinternal conical connectionen_US
dc.subjectremoval torqueen_US
dc.subjectscrewen_US
dc.subjectzirconiaen_US
dc.titleScrew stability of CAD-CAM titanium and zirconia abutments on different implants: An in vitro studyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files