Screw stability of CAD-CAM titanium and zirconia abutments on different implants: An in vitro study

dc.authorid batak, burcu/0000-0001-5363-5067
dc.authorid Johnston, William Michael/0000-0002-4977-6569
dc.authorid Cakmak, Gulce/0000-0003-1751-9207
dc.authorscopusid 35583824600
dc.authorscopusid 57217863941
dc.authorscopusid 57211015010
dc.authorscopusid 34769682900
dc.authorwosid batak, burcu/HFZ-9892-2022
dc.authorwosid Cakmak, Gulce/GRE-6472-2022
dc.authorwosid ÇAKMAK, GONCA/C-6464-2018
dc.authorwosid Johnston, William Michael/E-8458-2012
dc.contributor.author Yilmaz, Burak
dc.contributor.author Cakmak, Gulce
dc.contributor.author Batak, Burcu
dc.contributor.author Johnston, William M.
dc.date.accessioned 2024-05-25T11:42:38Z
dc.date.available 2024-05-25T11:42:38Z
dc.date.issued 2021
dc.department Okan University en_US
dc.department-temp [Yilmaz, Burak] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland; [Yilmaz, Burak] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland; [Yilmaz, Burak; Johnston, William M.] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH 43210 USA; [Cakmak, Gulce] Istanbul Okan Univ, Dept Prosthodont, Fac Dent, Istanbul, Turkey; [Batak, Burcu] Ankara Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey en_US
dc.description batak, burcu/0000-0001-5363-5067; Johnston, William Michael/0000-0002-4977-6569; Cakmak, Gulce/0000-0003-1751-9207 en_US
dc.description.abstract Background Limited information is available regarding the removal torque values (RTVs) of screws of different abutment materials when used with different implants. Purpose To evaluate the effect of implant type and abutment material (zirconia; Zir and titanium; Ti) on the RTVs of abutment screws after cyclic loading. Materials and methods Internal conical connection implants (CC, OsseoSpeed TX) and modified internal conical connection implants (MCC, OsseoSpeed EV) (n = 10) were clamped in resin dies. Zir and Ti (N = 20) custom abutments were tightened to implants (20 Ncm for CC and 25 Ncm for MCC) as specified by their manufacturers. The abutments were cyclically loaded by using a sequentially increased loading protocol; 2-million cycles under 100 N, 3-million cycles under 200 N, and 2-million cycles under 300 N loads with 2 Hz. After 7 million cycles, RTVs (Ncm) were measured by using a torque gauge. The data were analyzed with ANOVA by using the restricted maximum likelihood estimation method. Tukey-Kramer adjustment was used for any significant interaction of implant-abutment pairs (alpha = 0.05). Results Two CC implants, 1 with Ti and 1 with Zir abutment, fractured during cyclic loading (under 300 N loads within the 6th and 7th million cycles) and discarded for statistical analysis. Only implant type had a significant effect on RTVs (p <0.001). Screws of Ti abutments on MCC implants had significantly higher RTVs than the screws of Ti (p = 0.003) and Zir (p = 0.005) abutments on CC implants. Conclusions Implant type affected the RTVs, however, the RTVs were higher than the initial torque values for all groups. Screws of Ti abutments on implant, which required greater initial torque values had higher RTVs than the screws of Ti and Zir abutments on the implant that required smaller initial torque values. RTVs were similar for Zir and Ti abutment screws within each implant type. en_US
dc.description.sponsorship Dentsply Implants Investigator Initiated Studies [I-AA-14-055] en_US
dc.description.sponsorship Dentsply Implants Investigator Initiated Studies, Grant/Award Number: I-AA-14-055 en_US
dc.identifier.citationcount 4
dc.identifier.doi 10.1111/cid.13001
dc.identifier.endpage 379 en_US
dc.identifier.issn 1523-0899
dc.identifier.issn 1708-8208
dc.identifier.issue 3 en_US
dc.identifier.pmid 33938119
dc.identifier.scopus 2-s2.0-85104995871
dc.identifier.scopusquality Q1
dc.identifier.startpage 373 en_US
dc.identifier.uri https://doi.org/10.1111/cid.13001
dc.identifier.uri https://hdl.handle.net/20.500.14517/1624
dc.identifier.volume 23 en_US
dc.identifier.wos WOS:000646075200001
dc.identifier.wosquality Q1
dc.language.iso en
dc.publisher Wiley en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 5
dc.subject abutment en_US
dc.subject internal conical connection en_US
dc.subject removal torque en_US
dc.subject screw en_US
dc.subject zirconia en_US
dc.title Screw stability of CAD-CAM titanium and zirconia abutments on different implants: An in vitro study en_US
dc.type Article en_US
dc.wos.citedbyCount 5

Files