Effect of different disinfection protocols on the surface properties of CAD-CAM denture base materials

dc.authoridFonseca, Manrique/0000-0003-4267-0515
dc.authoridSchimmel, Martin/0000-0001-9700-5534
dc.authoridCakmak, Gulce/0000-0003-1751-9207
dc.authorscopusid57224805406
dc.authorscopusid57217863941
dc.authorscopusid57204883280
dc.authorscopusid24485630400
dc.authorscopusid35583824600
dc.authorwosidatalay, sevda/AFQ-2553-2022
dc.authorwosidSchimmel, Martin/F-5694-2011
dc.contributor.authorAtalay, Sevda
dc.contributor.authorCakmak, Gulce
dc.contributor.authorFonseca, Manrique
dc.contributor.authorSchimmel, Martin
dc.contributor.authorYilmaz, Burak
dc.date.accessioned2024-05-25T11:38:52Z
dc.date.available2024-05-25T11:38:52Z
dc.date.issued2023
dc.departmentOkan Universityen_US
dc.department-temp[Atalay, Sevda] Istanbul Okan Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye; [Cakmak, Gulce] Univ Bern, Buser Fdn Scholar Implant Dent, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland; [Fonseca, Manrique; Schimmel, Martin; Yilmaz, Burak] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland; [Schimmel, Martin] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland; [Yilmaz, Burak] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland; [Yilmaz, Burak] Ohio State Univ, Div Restorat & Prosthet Dent, Columbus, OH USA; [Fonseca, Manrique] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburg Str 7, CH-3010 Bern, Switzerlanden_US
dc.descriptionFonseca, Manrique/0000-0003-4267-0515; Schimmel, Martin/0000-0001-9700-5534; Cakmak, Gulce/0000-0003-1751-9207en_US
dc.description.abstractStatement of problem. Which disinfection protocol provides optimal water contact angle and microhardness for computer-aided design and computer-aided manufacturing (CAD-CAM) polymethyl methacrylate (PMMA) materials is unclear.Purpose. The purpose of this in vitro study was to evaluate the effect of different disinfection protocols (1% sodium hypochlorite, denture cleanser gel, and effervescent tablet) on the water contact angle and microhardness of different CAD-CAM PMMA denture base materials by comparing them with a heat-polymerized PMMA.Material and methods. Disk-shaped specimens (o10x2 mm) were fabricated from 3 different CAD -CAM PMMAs-AvaDent (AV), Merz M-PM (M-PM), and Polident (Poli) -and a heat-polymerized PMMA (Vynacron) (CV) (n=21). Three disinfection protocols (1% sodium hypochlorite [HC], denture cleanser gel [GEL], an effervescent tablet [TAB]) were applied to simulate 180 days of cleansing. The water contact angle and microhardness of specimens were measured before and after disinfection and compared by using a 2-way ANOVA (a=.05).Results. For water contact angle, material (P=.010) and disinfection protocol (P=.002) had a significant effect. The material (P<.001), disinfection protocol (P=.001), and their interaction (P<.001) significantly affected the microhardness after disinfection. When the condition after disinfection was compared with that before disinfection, the water contact angle increased significantly in all material-disinfection protocol pairs (P<.025), and microhardness increased significantly in all material-disinfection protocol pairs (P<.040), except for GEL-(P=.689) or TAB-applied (P=.307) AV, HC-applied M-PM (P=.219), and TAB-applied Poli (P=.159).Conclusions. The material and disinfection protocol affected the water contact angle of all tested PMMAs after disinfection, resulting in more hydrophobic surfaces for heat-polymerized or CAD-CAM PMMAs. The microhardness of heat-polymerized PMMA was less than that of all CAD-CAM PMMAs after disinfection, regardless of the protocol. (J Prosthet Dent 2023;130:787-95)en_US
dc.identifier.citation6
dc.identifier.doi10.1016/j.prosdent.2021.12.007
dc.identifier.endpage795en_US
dc.identifier.issn0022-3913
dc.identifier.issn1097-6841
dc.identifier.issue5en_US
dc.identifier.pmid35148889
dc.identifier.scopus2-s2.0-85124302434
dc.identifier.scopusqualityQ1
dc.identifier.startpage787en_US
dc.identifier.urihttps://doi.org/10.1016/j.prosdent.2021.12.007
dc.identifier.urihttps://hdl.handle.net/20.500.14517/1301
dc.identifier.volume130en_US
dc.identifier.wosWOS:001112186100001
dc.identifier.wosqualityQ1
dc.language.isoen
dc.publisherMosby-elsevieren_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subject[No Keyword Available]en_US
dc.titleEffect of different disinfection protocols on the surface properties of CAD-CAM denture base materialsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files