Retention of luting agents used for implant-supported restorations: A comparative In-Vitro study
No Thumbnail Available
Date
2020
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Wolters Kluwer Medknow Publications
Open Access Color
OpenAIRE Downloads
OpenAIRE Views
Abstract
Aims: The aim of this study was to compare the retention of different luting agents used with implant-supported restorations. Materials and Methods: A total of 90 custom metal frameworks and copings were prepared and divided into six different luting agent groups (n = 15/group): polycarboxylate cement (PC), resin-modified glass-ionomer cement (RMGIC), two self-adhesive resin cements (SARC), copper-ion zinc-phosphate cement (CZPC), and non-eugenol temporary resin cement (TRC). After sandblasting with 50 mu m Al2O3, the copings were cemented on frameworks and stored in artificial saliva for 48 h at 37 degrees C and thermocycled between 5-55 degrees C for 37,500 cycles. Samples were subjected to tensile testing by a universal testing machine, and data were statistically analyzed. Results: The differences between the retention values of types of cement were significant (P < 0.05). The maximum retention value was calculated for CZPC (755,12 +/- 55 MPa) while the lowest value was for TRC (311,7 +/- 61 Mpa). Conclusion: Neither of the tested cement had superiority over another to ensuring retention. The types of cement presented were meant to be a discretionary guide for the clinician in deciding the amount of the desired retention between castings and abutments.
Description
Keywords
Cemented abutments, fixed prosthesis, restoration removal
Turkish CoHE Thesis Center URL
Fields of Science
Citation
1
WoS Q
Q4
Scopus Q
Q2
Source
Volume
23
Issue
8
Start Page
1073
End Page
1078