Evaluation of flexural strength and surface properties of prepolymerized CAD/CAM PMMA-based polymers used for digital 3D complete dentures
dc.authorid | murat, sema/0000-0003-0632-5095 | |
dc.authorid | Cakmak, Gulce/0000-0003-1751-9207 | |
dc.authorwosid | murat, sema/AAS-2104-2020 | |
dc.contributor.author | Arslan, M. | |
dc.contributor.author | Murat, S. | |
dc.contributor.author | Alp, G. | |
dc.contributor.author | Zaimoglu, A. | |
dc.date.accessioned | 2024-10-15T20:21:47Z | |
dc.date.available | 2024-10-15T20:21:47Z | |
dc.date.issued | 2018 | |
dc.department | Okan University | en_US |
dc.department-temp | [Arslan, M.] Istanbul Aydin Univ, Prosthodont, Istanbul, Turkey; [Murat, S.] Besevler Ankara Univ, Ankara, Turkey; [Alp, G.] Okan Univ, Prosthodont, Istanbul, Turkey; [Zaimoglu, A.] Istanbul Aydin Univ, Prosthodont, Istanbul, Turkey | en_US |
dc.description | murat, sema/0000-0003-0632-5095; Cakmak, Gulce/0000-0003-1751-9207 | en_US |
dc.description.abstract | Purpose: The objectives of this in vitro study were to evaluate the flexural strength (FS), surface roughness (R-a), and hydrophobicity of polymethylmethacrylate (PMMA)-based computer-aided design/computer-aided manufacturing (CAD/CAM) polymers and to compare the properties of different CAD/CAM PMMA-based polymers with conventional heat-polymerized PMMA following thermal cycling. Materials and methods: Twenty rectangular-shaped specimens (64 x 10 x 3.3 mm) were fabricated from three CAD/CAM PMMA-based polymers (M-PM Disc [M], AvaDent Puck Disc [A], and Pink CAD/CAM Disc Polident [P], and one conventional heat-polymerized PMMA (Promolux [C]), according to ISO 20795-1: 2013 standards. The specimens were divided into two subgroups (n = 10), a control and a thermocycled group. The specimens in the thermocycled group were subjected to 5000 thermal cycling procedures (5 to 55 degrees C; 30 s dwell times). The R-a value was measured using a profilometer. Contact angle (CA) was assessed using the sessile drop method to evaluate surface hydrophobicity. In addition, the FS of the specimens was tested in a universal testing machine at a crosshead speed of 1.0 mm/min. Surface texture of the materials was assessed using scanning electron microscope (SEM). The data were analyzed using two-way analysis of variance (ANOVA), followed by Tukey's HSD post-hoc test (alpha < 0.05). Results: CAD/CAM PMMA-based polymers showed significantly higher FS than conventional heat-polymerized PMMA for each group (P < 0.001). CAD/CAM PMMA-based polymer [P] showed the highest FS, whereas conventional PMMA [C] showed the lowest FS before and after thermal cycling (P < 0.001). There were no significant differences among the R-a values of the tested denture base polymers in the control group (P > 0.05). In the thermocycled group, the lowest R-a value was observed for CAD/CAM PMMA-based polymer [M] (P < 0.001), whereas CAD/CAM PMMA-based polymers [A] and [P], and conventional PMMA [C] had similar R-a values (P > 0.05). Conventional PMMA [C] had a significantly lower CA and consequently lower hydrophobicity compared to the CAD/CAM polymers in the control group (P < 0.001). In the thermocycled group, CAD/CAM PMMA-based polymer [A] and conventional PMMA [C] had significantly higher CA, and consequently higher hydrophobicity when compared to CAD/CAM polymers [M] and [P] (P < 0.001). However, no significant differences were found among the other materials (P > 0.05). Conclusions: The FS and hydrophobicity of the CAD/CAM PMMA-based polymers were higher than the conventional heat-polymerized PMMA, whereas the CAD/CAM PMMA-based polymers had similar R-a values to the conventional PMMA. Thermocycling had a significant effect on FS and hydrophobicity except for the R-a of denture base materials. | en_US |
dc.description.woscitationindex | Science Citation Index Expanded | |
dc.identifier.citation | 71 | |
dc.identifier.doi | [WOS-DOI-BELIRLENECEK-74] | |
dc.identifier.endpage | 40 | en_US |
dc.identifier.issn | 1463-4201 | |
dc.identifier.issue | 1 | en_US |
dc.identifier.pmid | 29610779 | |
dc.identifier.scopusquality | Q3 | |
dc.identifier.startpage | 31 | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.14517/6679 | |
dc.identifier.volume | 21 | en_US |
dc.identifier.wos | WOS:000430322500005 | |
dc.identifier.wosquality | Q4 | |
dc.language.iso | en | |
dc.publisher | Quintessence Publishing Co inc | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | CAD/CAM | en_US |
dc.subject | digital complete dentures | en_US |
dc.subject | flexural strength (FS) | en_US |
dc.subject | hydrophobicity | en_US |
dc.subject | PMMA | en_US |
dc.subject | surface roughness (R-a) | en_US |
dc.title | Evaluation of flexural strength and surface properties of prepolymerized CAD/CAM PMMA-based polymers used for digital 3D complete dentures | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |