Determination of the Optimum Torque to Tighten the Smartpegs of Magnetic Resonance Frequency Analyses Devices: An Ex Vivo Study

dc.authoridBilmenoglu, Caglar/0000-0002-2580-9899
dc.authoridGECKILI, ONUR/0000-0002-7852-3915
dc.authoridCilingir, Altug/0000-0002-0694-5772
dc.authoridBilhan, Hakan/0000-0003-1787-3003
dc.authorscopusid15135391400
dc.authorscopusid14012620400
dc.authorscopusid16548947000
dc.authorscopusid54880603900
dc.authorscopusid35267920900
dc.authorwosidBURAL, HAYRUNNİSA CANAN/AAE-1151-2020
dc.authorwosidBilmenoglu, Caglar/HGE-5706-2022
dc.authorwosidGECKILI, ONUR/AAD-4973-2020
dc.authorwosidCilingir, Altug/N-2262-2018
dc.contributor.authorGeckili, Onur
dc.contributor.authorCilingir, Altug
dc.contributor.authorBural, Canan
dc.contributor.authorBilmenoglu, Caglar
dc.contributor.authorBilhan, Hakan
dc.date.accessioned2024-05-25T11:18:11Z
dc.date.available2024-05-25T11:18:11Z
dc.date.issued2015
dc.departmentOkan Universityen_US
dc.department-temp[Geckili, Onur; Bural, Canan] Istanbul Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey; [Cilingir, Altug; Bilmenoglu, Caglar] Trakya Univ, Fac Dent, Dept Prosthodont, Edirne, Turkey; [Bilhan, Hakan] Okan Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkeyen_US
dc.descriptionBilmenoglu, Caglar/0000-0002-2580-9899; GECKILI, ONUR/0000-0002-7852-3915; Cilingir, Altug/0000-0002-0694-5772; Bilhan, Hakan/0000-0003-1787-3003en_US
dc.description.abstractThe aim of this study was to find an optimal value for tightening the Smartpegs for magnetic radiofrequency analysis devices (RFAs) devices. Thirty implants were placed in 3 cow ribs. The RFA value of each implant was measured in buccal and mesial directions after tightening the Smartpegs with 1, 3, 4, 8, 9, 10, and 11 Ncm. Additionally, 4 different examiners measured the RFA after hand tightening the Smartpegs, and the results were compared. The buccal implant stability quotient (ISQ) values when the Smartpegs were tightened to 1Ncm were significantly lower than the ISQ values when the Smartpegs were tightened to 3, 4, 8, 9, 10, and 11 Ncm (P<.05). The mesial ISQ values when the Smartpegs were tightened to 1, 3, and 4 Ncm were significantly lower than the ISQ values when the Smartpegs were tightened with higher torque values (P<.05). The buccal measurements made by 1 examiner was significantly lower than 3 Ncm (P<.05), and the buccal measurements made by 1 examiner was significantly lower than 4 Ncm (P<.05). The mesial ISQ values measured by 2 examiners were significantly lower than 3 Ncm (P<.05), and the mesial ISQ values measured by the other 2 examiners were significantly lower than 8 Ncm (P<.05). The tightening of the Smartpegs should be standardized by the manufacturer to a range of 5-8 Ncm in order to gain reliable objective RFA values, instead of leaving it to subjective finger pressure.en_US
dc.identifier.citation8
dc.identifier.doi10.1563/aaid-joi-D-14-00266
dc.identifier.endpageE256en_US
dc.identifier.issn0160-6972
dc.identifier.issn1548-1336
dc.identifier.issue6en_US
dc.identifier.pmid25668680
dc.identifier.scopus2-s2.0-84949937508
dc.identifier.scopusqualityQ2
dc.identifier.startpageE252en_US
dc.identifier.urihttps://doi.org/10.1563/aaid-joi-D-14-00266
dc.identifier.urihttps://hdl.handle.net/20.500.14517/308
dc.identifier.volume41en_US
dc.identifier.wosWOS:000366723300003
dc.identifier.wosqualityQ4
dc.language.isoen
dc.publisherAllen Press incen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectdental implantsen_US
dc.subjectradiofrequency analysisen_US
dc.subjectosseointegrationen_US
dc.subjectprimary stabilityen_US
dc.titleDetermination of the Optimum Torque to Tighten the Smartpegs of Magnetic Resonance Frequency Analyses Devices: An Ex Vivo Studyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files